the most complete monitoring solution on the market

Slides:



Advertisements
Similar presentations
Welcome to the Radionet Monitoring Secure-Com Presentation.
Advertisements

Compliance Verification Testing of Installed ESD Protective Products
Isolation Verification Control Mining - Marine - Transit – Solutions LIVE Distributed By Locksafe Industrial Safety Equipment.
DATA ACQUISITION SmartLog X3 DescoEMIT.com Rev:
DescoEMIT.com Made in United States of America Rev: EMIT ESD Monitoring, Ionization & Test EMIT ESD Monitoring, Ionization & Test SmartLog V5™
Ohm Metrics CM2800 Series ULV Digital Dual Workstation Monitor and Network ©2011 All Rights Reserved.
OVERVIEW TEAM5 SOFTWARE The TEAM5 software manages personnel and test data for personal ESD grounding devices. Test and personnel data may be viewed/reported.
Emit.descoindustries.com Made in United States of America Rev: EMIT ESD Monitoring, Ionization & Test EMIT ESD Monitoring, Ionization & Test.
11/2010©Copyright 2010 Desco Industries Inc Dual Operator Continuous Monitor with Satellites.
Register Digital Multimeter Usage Click Register to begin the course.
Protection against Lightning Overvoltages Overvoltages due to lightning strokes can be avoided or minimized in practice by (d) shielding the overhead lines.
S Changes and Procedures
Model Continuous Workstation Monitor, Dual Wire ©Copyright 2003 DESCO INDUSTRIES INC.
Made in United States of America EMIT SIM emit.descoindustries.com Rev:
© 2015 Vermason Ltd. SmartLog V5 ™ with Turnstile.
Made in United States of America emit.descoindustries.com Copyright ® Desco Industries, Inc. Rev: Rev
Chapter 21 Electricity. Opposite charges attract, like repel Charged objects can cause electrons to rearrange their positions on a neutral object.
7.2.3 Student Book © 2005 Propane Education & Research CouncilPage Identifying Procedures for Measuring Resistance Between Two Given Points in.
Sensors and Electricity. What is a Sensor? A sensor is a device that: A sensor is a device that: 1) Measures a physical quantity 2) Converts this measurement.
1 Safety and Preventative Maintenance. 2 MB, One megabyte - MB or M-byte - represents about 1 million (10 6 ) bytes. Precisely, 1 MB = = 1 kB x 1 kB =
The Mini Zero Volt Monitor (ZVM)
Gauge Operation and Software by Scott A. Ager. Computer Recommendations 750 MHz Pentium III 64 Meg SRAM 40 Gig Hard Drive 1024 x 768 graphics CD Writer.
Register Digital Multimeter Usage Click Register to begin the course.
Made in United States of America ZVM Solo EMIT ZVM Solo the most complete monitoring solution on the market.
Copyright ® Desco Industries, Inc. Rev: Rev
Voltage, V Voltage tells us how hard a positive charge is pushed between two different points. Something, such as a battery, is needed to create a voltage.
©Copyright 2015 SmartLog V5 ™ with Turnstile. SmartLog V5™ with Turnstile Charleswater.co.uk The patented* EMIT SmartLog V5™ is designed for fast, frequent,
Wireless TL70 Sure Cross ® Wireless TL70 Tower Lights combine the best of Banner’s popular Tower Light family with the reliable, field-proven, Sure Cross.
New Product Developments World Leaders in Combustion Management Solutions New Products New Products.
© 2015 Desco Industries Inc. StaticControl.com Formerly known as 3M Static Control Static Management Program.
Electric Circuits. Section 1: Electromotive Force & Current.
Electric Charges Three particles that make up an atom: Three particles that make up an atom: Protons Protons Neutrons Neutrons Electrons Electrons POSITIVE.
Competitive Advantages. Every Auto Door Project Should Use LazerPoint RF™ Wireless Example Cost to Install 2 Wired Switches (Surface Mount) Equipment:
Made in the United States of America DescoEMIT.com EMIT ESD RESULTS AT YOUR FINGERTIPS.
ESD RESULTS AT YOUR FINGERTIPS Charleswater.co.uk.
Interfaces 101 Interfaces provide connectivity for the drawers to virtually any POS device (printer, terminal, tablet etc.) in the industry.
Technology from Desco ® Copyright 2017.
Copyright 2014 Associated Research, Inc.
ELECTRICAL CIRCUITS Multimeter.
Starting System Circuit Operation and Testing
ESD RESULTS AT YOUR FINGERTIPS
Static Management Program (SMP)
Temperature sensors Temperature is the most often-measured environmental quantity. This might be expected since most physical, electronic, chemical, mechanical,
Grounding.
Kevin Boyce Director of Product Management, LED Drivers
Introduction to Semiconductor Devices
GROUND-FAULT GROUND-CHECK MONITOR
The D.C. Scout Battery Distribution System Ground Locator
The advantages of going wireless
EMIT DescoEMIT.com ESD RESULTS AT YOUR FINGERTIPS
Unit 2.3 Electric Current.
Rev Copyright ® Desco Industries, Inc. Rev:
The Electric Circuit.
Unit 2.4 Electric Circuits
Electricity Electric Current.
Administration Training
Dual-Wire Dual-Operator Programmable Continuous Monitor
THERMOMETER PROJECT PCB ASSEMBLY INSTRUCTIONS Ver: 3.21 edutek.ltd.uk.
COMPONENTS.
Static Management Program (SMP)
S8910U1000 Universal Electronic Ignition Modules Training Module
ESD Procedures for the Electronics Industry
How an NPN Transistor Works
Multimeter Purpose Used to measure Voltage and Current around a circuit. Multimeter is the generic name given to the universal, Volt, Amp, and Ohmmeter.
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
Current electricity Ch. 34
Universal Interrupted Electronic Oil Primary R7184U Training Module
724 Temperature Calibrator
Presentation transcript:

the most complete monitoring solution on the market ZVM Solo EMIT ZVM Solo the most complete monitoring solution on the market REV 2012-04 emit.descoindustries.com

ZVM Solo First Single Workstation Dual-Wire Continuous Monitor by EMIT EMIT previously only offered dual workstation, dual-wire monitors Zero Volt Monitor (ZVM), Dual Programmable Monitor Workstations are now commonly setup as stand-alone or pods. Dual workstation monitors are not an ideal solution for these setups. The ZVM Solo monitors one operator, one supervisor (optional), one worksurface and one ESD tool / fixture / accessory The ZVM Solo was specifically designed to be mounted underneath bench tops. This may be accomplished using the included Velcro strips or optional 50578 stainless steel bracket. emit.descoindustries.com

ZVM Solo EMIT SIM Software Compatibility The all-new 50152 EMIT SIM Software is designed to monitor and record the activity of all EMIT Smart Products Use EMIT SIM to fulfill ANSI/ESD S20.20-2007 section 7.3: “Compliance verification records shall be established and maintained to provide evidence of conformity to the technical requirements.” Save cost by eliminating the need for supervisors to physically check the status of monitors and ionizers every day EMIT SIM automatically manages calibration schedules and alerts when any one group of devices need calibration or maintenance EMIT SIM is compatible with the ZVM Solo, Dual Programmable Monitor, ZVM, ULVM and Zero Volt Ionizers. It is the only software on the market capable of recording both monitor and ionizer activity. emit.descoindustries.com

ZVM Solo True Continuous Monitoring The ZVM Solo offers true continuous monitoring; pulsed monitors do not Fastest response time on the market (.058 seconds typical) Pulsed technology is off 90% of the time and misses intermittent connections ON ZVM Solo The key feature that sets EMIT monitors apart from the competition is our “true continuous monitoring.” Since our test voltage is so low, it can continuously be applied to an operator without yielding any skin irritation. This technology allows the ZVM Solo to carry the fastest response time for any dual-wire monitor. The ZVM Solo indicates all failures at the instant that they happen. Pulsed monitors are not “true continuous monitors.” The graph above indicates that they only monitor about 10% of the time that they are on. They also take longer to indicate any failures. Pulsed Monitor Pulsed only monitors 10% of time OFF emit.descoindustries.com

ZVM Solo Patented Zero Volt Technology Dual-wire wrist straps provide redundant grounding (still grounded if one wire breaks) Dual polarity technology places positive voltage on one line and negative voltage on the other, resulting in near zero volts at the operator There are two wrist strap types: single-wire and dual-wire. The EMIT ZVM Solo is used to test dual-wire wrist straps. Examples of a dual-wire wrist band and wrist cord can be seen above. The key advantage of dual-wire wrist straps is redundant grounding. If one of the two wires were to break, the operator would still have a path to ground with the other wire. The ZVM Solo uses patented dual-polarity technology. This is accomplished by sending equal but opposite voltages across each wire. When both voltages meet at the operator, they cancel each other out, resulting in near zero voltage on the operator. emit.descoindustries.com

ZVM Solo Operator Charge Detection Detects operator voltage charge >±2.5VDC The ZVM Solo has dedicated LEDs for operator resistance and charge detect. If operator failure occurs on a competitor’s monitor, one cannot distinguish whether it was due to resistance or charge failure The charge detection circuit is capable of detecting a voltage leak on the operator. This threshold may be set to either ±2.5V or ± 1.25V. This feature provides an effective way of alerting the operator when they come in contact with charge generating materials or practices at their workstation. A good example would be rolling a non-ESD chair over a non-ESD floor or using an improperly grounded ESD chair. To demonstrate this feature, connect yourself to the monitor, touch one of the battery’s terminals, and then place the other terminal to the monitor’s sheet metal (or hard ground). This will apply 9 volts to your body and cause the monitor to alarm (charge LED red). emit.descoindustries.com

ZVM Solo User Adjustable Features With a specific set of instructions provided by EMIT, the customer can open the ZVM Solo and configure a set of DIP switches to modify the following features: Operator test voltage: 50mV or 1.25V Worksurface limit: 3 ohm or 3 megohms Operator charge detect: ±1.25V or ± 2.5V Mat circuit: ON / OFF Tool circuit: ON / OFF Charge detect circuit: ON / OFF The ZVM Solo has adjustable features that allow the user to change the operator test voltage, worksurface limit and charge detect voltage. The operator test voltage can be set to either 1.25V or 50mV. The 50mV setting is ideal for use with Class 0 devices and must be used with a metal wrist strap. The worksurface limit can be set to either 3 megohms or 3 ohms for highly conductive materials. The sensitivity of the charge detect circuit may be adjusted from 2.5V to 1.25V for Class 0 workstations. The MAT and TOOL circuits may also be disabled when not in use. emit.descoindustries.com

ZVM Solo Competitive Breakdown emit.descoindustries.com The ZVM Solo outperforms all popular dual-wire monitors. Its software compatibility separates it from the 3M monitors. The ZVM Solo is also an upgrade from the EMIT ZVM and Dual Programmable Monitor. Should a customer want to use EMIT SIM with their existing ZVM and Dual Programmable Monitor inventory, the EMIT Smart Hub will need to be purchased. The ZVM Solo was designed in conjunction with EMIT SIM, so its specs were tailored for optimum software compatibility. It is the fastest polling monitor and features a memory cache for time stamping status changes. *The 3M 724 is set up to monitor two operators that are seated side by side at the same workstation and relies on a daisy-chaining to monitor the workstations. It may upgraded with an additional remote to monitor a second operator at an adjacent workstation. emit.descoindustries.com

ZVM Solo Targeted Customers Users of the following monitors: 3M Workstation Monitor 724 EMIT Zero Volt Monitor (ZVM) 3M Iron Man Plus CTC331 EMIT Dual Programmable Monitor emit.descoindustries.com

Register All Opportunities on emit.descoindustries.com Visit the following webpage and log-in to complete the registered opportunities form: http://emit.descoindustries.com/Rep/RegisteredOpportunity.aspx EMIT (909) 664-9980 Service@DescoEMIT.com emit.descoindustries.com emit.descoindustries.com