What you need to know about ASPIJECT ® & local dental anaesthesia Quality you can Feel! ASPIJECT.

Slides:



Advertisements
Similar presentations
INITIATE AN INTRAVENOUS INFUSION
Advertisements

Laboratory Animal Handling Technique
The Cartridge.
The Armamentarium 4 PARTS: 1) The Syringe 2) The Needle 3) The Cartridge 4) Preparation.
Armamentarium.
PLATEPRO PHOTOPOLYMER PLATEPRO PHOTOPOLYMER Pre-wash The Photopolymer+CTP plate processor has an integrated Pre-heat and Pre-wash system. The plate processors.
Preparing the Anesthetic Syringe
Large Taper Files. Engine-driven files Hand-Using Large Taper Files.
EQUIPMENT IN L.A. Equipment has been developed for LA administration to be convenient in use and to be sterile ( read history). Sterilization: removal.
LIGHT-DUTY BELT FASTENER SYSTEMS
MUNCHY THE CATERPILLAR PRODUCT RELEASE DOCUMENT TM.
THE M-9 9MM SERVICE PISTOL
Use and Maintenance of Micro-pipettes
Module 3: Marking out and Hand Tools
Sim. Lab Activity 2 Working in Balance (WIB): Access, Visibility and Isolation JANET WEBER, RDH, M.Ed.
EMerge Medical Pty Ltd PO Box 333 Nth Sydney NSW 2059 Australia Tel: Fax ANAESTHESIA.
Drug Delivery & Tissue Engineering Laboratory
INFECTION CONTROL COMPLIANCE Non Compliance with Dental School Infection Control Standards, can result in the spread of blood-borne pathogens, and other.
Withdrawing Solution From an Ampule
Page 1 of 28 Modular Instruments for Suction and Irrigation Versatile and Precise Presentation Suction- and Irrigation Systems presents:
DENT 1160 Pharmacology Local Anesthetic 1. Aspirating syringe Has harpoon, so Dr can inject a small amount and pull back to check for blood in carpule.
Machining is processes in which we get a desired final shape and size from of raw material. 1.Conventional / Traditional Machining 2.Non Conventional.
Nom - Stainless steel range: screwdrivers and hex keys.
The machine is built to comply with the accident prevention, hygiene and electric standards in force. MODUL SERIES MODULAR DECK OVENS Control panel features:
Periodontal Scaling Instruments (Gracey Curettes and Sickle Scalers)
Our PREMIER INSTRUMENTS line of surgical tools are manufactured at ISO 9001 certified facilities using only the finest quality German surgical Stainless.
Intra-Operative fluid warmer device. Department of Reconstructive Sciences, Health Campus, USM.
Cytology and Cytological Techniques
Administration of Vaccine via Intramuscular Route
AIR BEARING SYSTEM.
Local Complications in Anesthesia Administration.
Session V A, Slide #1 Contraceptive Implants Session V A: Two-Rod Implant Insertion.
COPYRIGHT SILCA SpA 2007 Bravo ProfessionalSilca S.p.A. Bravo Professional.
Flex Cam – Training This shows one version of a complete FlexCam system including Power Unit HCP and Compact Cam CC for piercing operation.
Copyright © 2008 Wolters Kluwer Health | Lippincott Williams & Wilkins Dental Mirror.
E NVIRONMENTAL AND PATIENT / THERAPIST SAFETY. Preparation for Patient Care Preparing clear patient care environment/ room Preparation of the treatment.
Launch Chameleon Plus P - More Preventive features and safety L - More Longer Lasting and robust U - More User friendly operation S - More Service friendly.
Bravo Maxima.
Epidural Anaesthesia.
CHAPTER 6 Microbiology-Related Procedures
Introduction In natural environments, microorganisms usually exist as mixed populations. However, if we are to study, characterize, and identify microorganisms,
Chemical Sterilization
Flux Cored Arc Welding (FCAW)
Copyright Silca S.p.A REKORD Copyright Silca S.p.A REKORD 2000 Results of major research which involved every single component, Rekord.
Applications of Nano Coating in Air-Conditioning Technology Basic Principles and Practical Examples LORDAN.
Design Guidelines Injection Moulding Engineering Design.
EZ Zone ® Tape PURGE GAS RETAINING TAPE US & FOREIGN PATENTS PENDING FOR CLEAN CONTAMINANT-FREE WELDING MADE IN THE USA.
Lesson XIII: Anesthesia
OBJECTIVES Discuss parking brake pedals and automatic parking brake release. Explain parking brake linkages. Describe drum parking brakes. Describe caliper-actuated.
Fixture.
Forge Welding Welding Technology/ 3.6 Forge Welding.
Exodontia General arrangement or considerations for extraction:
PRESS RELEASE The utmost easy cleaning and corrosion resistance.
INTRODUCTION.
Techniques in Molecular Biology 2017 Fall Lecture -2-
KNIVES Disclaimer: I do not own the rights not property of this powerpoint presentation. All rights reserved to the owner. Do not forget to follow me on.
Acti-Lance Safety Lancet
Ariana Kevelier Paul King Building Technology III
Techniques in Molecular Biology 2017 Fall Lecture -2-
Use and Maintenance of Micro-pipettes
KaVo SUPERtorque ingenious angle combination SUPERtorque 660
PDLA Advantages and Indications
GENTLEsilence LUX 8000 B ... fascinating silence
Contraceptive Implants Session V A: Two-Rod Implant Insertion
Contraceptive Implants Session IV A: One-Rod Implant Insertion
Clutches.
Presented By : S.Pradeep (AP/MCT)
Microbiology-Related Procedures
Contraceptive Implants Session V A: Two-Rod Implant Insertion
INJECTION MOLD DESIGN PDT 317
Presentation transcript:

What you need to know about ASPIJECT ® & local dental anaesthesia Quality you can Feel! ASPIJECT

Introduction ASPIJECT ® can be used with any standard dental cartridge and needle. ASPIJECT ® is a self-aspirating dental cartridge syringe for infiltration and block anaesthesia. The ASPIJECT ® syringe was developed in co-operation with D.D.S. Dr. Odont h.c. Hans Evers from Sweden and other Scandinavian experts. ASPIJECT ® was introduced in 1981.

ASPIJECT ® Features Ergonomics Unique grip design giving a comfortable ergonomic shape. Short distance between grips – advantageous to users with below average hand size. Not as threatening to patients Well-balanced, good feel. Provides excellent Tactile Sensitivity Lightweight (50g) but solid construction.

ASPIJECT Quality Construction: Made from high-grade acid resistant stainless steel and heat resistant polymer. (No chromium plating to come off.) No screw assemblies to loose. (harpoon, hub) Easy to load, unload and clean. Withstands sterilization to 200 degrees C / 390 degress F. Smooth, hygienic surface. Surface of the syringe has a matt finish - does not reflect sharp light. Can use with standard dental cartridge and needle.

Aspiration What is aspiration? Aspiration is performed to prevent an intravascular injection. When to aspirate? Prior to injection. Basic principle of aspiration? To create a negative pressure in the cartridge so that liquid from the tissue at the deposition site is sucked up.

ASPIJECT ® and the self-aspirating principle Every time during injection, when thumb force is realeased, aspiration is automatically produced with ASPIJECT ®. A light thumb force on the T-handle pushes the cartridge onto the hub at base of the syringe. This causes distortion (against the hub) of the diaphragm at the needle end of the cartridge. By quickly releasing thumb force from the T-handle, the diaphragm relaxes and the elastic recoil creates the negative pressure that secures distinct aspiration.

ASPIJECT ® and the self-aspirating principle The self-aspirating principle eliminates grip change or inadvertent repositioning of the needle tip. Aspiration can also be produced by depressing and releasing the thumb disc. By depressing the thumb disc, the force is transferred directly to the glass wall of the cartridge, making the aspiration result independent of different cartridges properties.

Maintenance of the ASPIJECT ® ASPIJECT ® is made from high-grade acid resistant stainless steel and special heat resistant engineering polymer. The syringe can be sterilizied by any method withstanding temperatures until 200ºC. Like all stainless steel instruments, the syringe should be carefully cleaned and rinsed before sterilization. (Anaesthetic solutions are highly acidic). When attention is paid to these few pieces of advice, ASPIJECT ® will function and appear as new for many years.

Advantages ASPIJECT ® Withstands repeated sterilization by any method (Max 200ºC / 390ºF). Possible to load without needle penetrating the diaphragm to avoid ion contamination of the anaesthetic solution. Side – loading. Quick and easy with large window. No need to change grip when moving from aspiration to injection and therefore minimized risk of needle tip movement. Tactile sensitivity is enhanced by the solid one piece machined designed. There is a 5 year material and construction guarantee on ASPIJECT ® syringes.