Trouble Shooting with ELQ 30A+

Slides:



Advertisements
Similar presentations
ELQ 30 Preprogrammed VDSL-2 Band Plans
Advertisements

Common Customer Issue: I2C Cable Glitches
CCNA 1 v3.1 Module 4 Cable Testing. Purpose of This PowerPoint This PowerPoint primarily consists of the Target Indicators (TIs) of this module in CCNA.
Trouble Shooting with ELQ 30 CROSSTALK BRIDGED TAPS INTERRUPTION UNBALANCE Typical Cable Problems ELEKTR NIKA To learn more click on the selected topic!
DCN286 Introduction to Data Communication Technology Session 5.
ELEKTR NIKA Upstream Power Back Off (UPBO) The Problem is: Upstream bit rates on long loops are dramatically reduced. Very high-speed digital subscriber.
ELEKTR NIKA VDSL 2 Vectoring The Problem: The bit rate of VDSL2 lines is limited by the crosstalk noise. Typical a cable bundle comprises several tens.
Application Notes for Line Testing with ET 91 To learn more click on note! Single Sided Measurements END to END Measurements LCL Balance Impedance Return.
To learn more click on the selected method! Typical Cable Faults Unbalance Recommended Fault Location Method Disturbing voltage ▼ Murray ▼ Küpmüller ▼
Automatic xDSL Test Sequences of ELQ 30A
Application Notes for Frequency Division Multiplex System Testing with ET 91 To learn more click on note! Basic, Super & Master Group Voice Frequency Noise.
ELEKTR NIKA To learn more click on the selected topic! Manual End to End Measuring Modes of ELQ 30A ► ► ► ► ► ► Loss Measurement with MTTS Group Delay.
Automatic Single Sided Test Sequence of ELQ 30A To learn more click on the selected topic! ELQ 30A provides single sided test sequences to estimate the.
FREQUENCY CONTROL MODES OF ET 91 To learn more click on note! END to END Loss Measurement Group Delay Distortion Measurement Frequency Tracking with Sweep.
Trouble Shooting with EFL 10 Insulation Faults Flooded cable R b ≠ R aC b ≠ C a Typical Cable Problems Which one is the Proper Fault Location Method ?
Arctic RS-485 / RS-422. RS- 485 Also known as RS-485 Half Duplex, RS wire same pair is used to transmit and receive data only one device can transmit.
Troubleshooting Tools Cable Performance Testers Voltage Event Recorders Butt Set Crossover Cable Tone Generator & Locator Multimeter Cable Continuity Tester.
Single Ended Measuring Modes of ELQ 30A To learn more click on the selected topic! ELEKTR NIKA Receiving Modes Impulse Noise Measurement Spectrum Analyzer.
1 Discovery 2, Ch 4 Notes. 222 Cabling Standards Standards ensure that networks perform to expectations US—IEEE & ANSI/TIA/EIA Canada—CSA (Canadian Standards.
Long Time Spectrogram Measurement with ET 91 The results are displayed on a 3 dimension picture ■ The time is on the vertical axis ■ The frequency is on.
CCNA1 v3 Module 4 v3 CCNA 1 Module 4 JEOPARDY S Dow.
Automatic Voice Frequency Test Sequences of ELQ 30A To learn more click on the selected topic! The Automatic Master-Slave Measuring mode is intended for.
Which one is the Proper Fault Location Method ?
Single Ended Line Test with Upgraded ECFL 30
XDSL Line Tester Modem EX 30M ELEKTR NIKA EX 30M is a handheld, cost-effective test set to check DSL services and the copper cable capability. It is a.
PLC Testing with ET 91 Level Test Set To learn more click on note! Pilot Level Measurement on RF Test Point Measurements in Special Tracking Mode Pilot.
Frequency Division Multiplex System Testing with ET 92 To learn more click on note! Basic, Super & Master Group Voice Frequency Noise END to END Measurements.
Downstream Power Back Off (DPBO)
Manual Measuring Modes of ELA 10 To learn more click on the selected topic! Level, Loss Noise, Spectrum Line Parameter Optional Measurements Transmitting.
CHOOSE 1 OF THESE.
FREQUENCY CONTROL MODES OF ET 91 To learn more click on note! END to END Loss Measurement Group Delay Distortion Measurement Conventional Setting Modes.
Single Ended Measuring Modes of ELQ 30A+
Pertemuan 10 Signal & Noise
To learn more click on the selected system!
VDSL 2 Vectoring ELEKTR NIKA
Manual End to End Measuring Modes of ELQ 30A+
Trouble Shooting with EFL 10
Automatic xDSL Test Sequences of ELQ 30A+
Trouble Shooting with ELQ 35
Chapter 4 Baseband Pulse Transmission
رؤية مستقبلية لتطوير كلية الزراعة جامعة الفيوم
Features For more information, visit us at: smart-bracelet-h3 Thank You.
Single Ended Line Test with Upgraded ECFL 30
Telephone & Exchange Tester ETET 30
xDSL Line Tester Modem EX 30M
دانشگاه شهیدرجایی تهران
Telephone & Exchange Tester ETET 30
Trouble Shooting with ELQ 30
VDSL 2 Vectoring ELEKTR NIKA
Automatic Voice Frequency Test Sequences of ELQ 30A+
تعهدات مشتری در کنوانسیون بیع بین المللی
Which one is the Proper Fault Location Method ?
Which one is the Proper Fault Location Method ?
Downstream Power Back Off (DPBO)
xDSL Line Tester Modem EX 30M
Downstream Power Back Off (DPBO)
Single Ended Line Test with Upgraded ECFL 30
xDSL Line Tester Modem EX 30M
Automatic Single Sided Test Sequence of ELQ 30A+
How to Connect a Dell Printer to Your PC. Connecting a Wired Printer on Windows 1. Set your printer near your PC.
Thank You!! For More Information Visit: m/ Call to :
Manual Measuring Modes of ELA 10
Manual Measuring Modes of ELA 10
VDSL 2 Vectoring ELEKTR NIKA
CCNA 1 v3.1 Module 4 Cable Testing
Automatic Test Sequences in Master-Slave Mode
Upstream Power Back Off (UPBO)
CCNA 1 v3.1 Module 4 Cable Testing
Automatic Test Sequences in Master-Slave Mode
Upstream Power Back Off (UPBO)
Presentation transcript:

Trouble Shooting with ELQ 30A+ Typical Cable Problems CROSSTALK BRIDGED TAPS INTERRUPTION UNBALANCE NEXT Measurement FEXT Measurement Location of XTALK Point Recognition of Bridged Taps Location of Bridged Taps Micro Interruption Detection Location of Loose Contacts LCL Balance Measurement To learn more click on the selected topic! ELEKTR NIKA

Near End Crosstalk Measurement ELQ 30A+ MASTER SLAVE ELQ 30A+ MASTER SLAVE FAIL ► ◄ PASS The location of cross talk point can be found by the TDR of ELQ 30A+ To visit the TDR page click on the key ELEKTR NIKA

Far End Crosstalk Measurement ELQ 30A+ MASTER SLAVE ELQ 30A+ MASTER SLAVE FAIL ► ◄ PASS The location of cross talk point can be found by the TDR of ELQ 30A+ To visit the TDR page click on the key ELEKTR NIKA

Crosstalk Point Location with TDR When the XTALK is out of limit it is very likely that the reason is split. The best tool to locate the XTALK points is ELQ 30A+ in TDRXTALK mode. ELQ 30A+ Split Resplit Typical Waveform ELEKTR NIKA

Recognition of Bridged Taps Impedance measurement is the best tool to recognize bridged taps because they cause strongly waving line impedance Typical impedance measurement result FAIL ► ◄ IRREGULAR The location of bridged tap can be found by the TDR of ELQ 30A+ To visit the TDR page click on the key ELEKTR NIKA

Bridged Tap Location with TDR When the line impedance is strongly waving it is very likely that the reason is bridged tap. The best tool to locate it the TDR of ELQ 30A+ Typical Waveform Distance to tap Length of tap ELEKTR NIKA

Micro Interruption Detection Micro interruption is a temporary line interruption due to loose contacts. ELQ 30A+ detects the micro interruptions using 1020 Hz test tone The location of loose contact can be found by long time TDR measurement To visit the TDR page click on the key ELEKTR NIKA

Loose Contact Location ELQ 30A+ in long time TDR mode performs a sequence of repeated measurements The obtained waveforms are different if the features of tested pair change during the test Typical Waveform ELEKTR NIKA

Balance (LCL ) Measurement ELQ 30A+ in Master-Slave mode provides a useful tool to find unbalance causing impairment of xDSL connections. ELQ 30A+ MASTER SLAVE ELQ 30A+ MASTER SLAVE PASS ► ◄ FAIL ELEKTR NIKA

THANK YOU FOR YOUR ATTENTION!