Presentation is loading. Please wait.

Presentation is loading. Please wait.

Trouble Shooting with ELQ 30

Similar presentations


Presentation on theme: "Trouble Shooting with ELQ 30"— Presentation transcript:

1 Trouble Shooting with ELQ 30
Typical Cable Problems CROSSTALK BRIDGED TAPS INTERRUPTION UNBALANCE NEXT Measurement FEXT Measurement Location of XTALK Point Recognition of Bridged Taps Location of Bridged Taps Micro Interruption Detection Location of Loose Contacts LCL Balance Measurement To learn more click on the selected topic! ELEKTR NIKA

2 Near End Crosstalk Measurement with ELQ 30
MASTER SLAVE ELQ 30 MASTER SLAVE FAIL PASS The location of cross talk point can be found by the TDR of ELQ 30 To visit the TDR page click on the key ELEKTR NIKA

3 Far End Crosstalk Measurement with ELQ 30
MASTER SLAVE ELQ 30 MASTER SLAVE FAIL PASS The location of cross talk point can be found by the TDR of ELQ 30 To visit the TDR page click on the key ELEKTR NIKA

4 Crosstalk Point Location with the TDR of ELQ 30
When the XTALK is out of limit it is very likely that the reason is split. The best tool to locate the XTALK points is ELQ 30 in TDRXTALK mode. ELQ Split Resplit Typical Waveform ELEKTR NIKA

5 Recognition of Bridged Taps
Impedance measurement is the best tool to recognize bridged taps because they cause strongly waving line impedance Typical impedance measurement result FAIL IRREGULAR The location of bridged tap can be found by the TDR of ELQ30 To visit the TDR page click on the key ELEKTR NIKA

6 Bridged Tap Location with the TDR of ELQ 30
When the line impedance is strongly waving it is very likely that the reason is bridged tap. The best tool to locate it the TDR of ELQ 30 Typical Waveform Distance to tap Length of tap ELEKTR NIKA

7 Micro Interruption Detection
Micro interruption is a temporary line interruption due to loose contacts. ELQ 30 detects the micro interruptions using 25 kHz test tone The location of loose contact can be found by long time TDR measurement To visit the TDR page click on the key ELEKTR NIKA

8 Loose Contact Location
ELQ 30 in long time TDR mode performs a sequence of repeated measurements The obtained waveforms are different if the features of tested pair change during the test Typical Waveform ELEKTR NIKA

9 Balance (LCL ) Measurement
ELQ 30 in Master-Slave mode provides a useful tool to find unbalance causing impairment of xDSL connections. ELQ 30 MASTER SLAVE ELQ 30 MASTER SLAVE PASS FAIL ELEKTR NIKA

10 THANK YOU FOR YOUR ATTENTION!


Download ppt "Trouble Shooting with ELQ 30"

Similar presentations


Ads by Google