Trouble Shooting with EFL 10

Similar presentations


Presentation on theme: "Trouble Shooting with EFL 10"— Presentation transcript:

1 Trouble Shooting with EFL 10
Which one is the Proper Fault Location Method ? Typical Cable Problems Insulation Faults Flooded cable R b ≠ R a C b ≠ C a Recommended Fault Location Method To learn more click on the selected method! ELEKTR NIKA

2 Recommended when only one wire of the tested pair is faulty.
Murray Method Recommended when only one wire of the tested pair is faulty. The result of Murray measurement is: Lx/L In addition EFL 10 provides:   ■ RL loop resistance   ■ FaE insulation resistance   ■ Rx resistance to fault ■ Lx distance to fault The conditions of accurate results:  ■ Ia and Ib < 450 uA  ■ Ф wire a=Ф wire b  ■ FbE>1000 x FaE  ■ FbE>10 MOhm ELEKTR NIKA

3 Recommended when both wires of the tested pair are faulty.
Küpfmüller Method Recommended when both wires of the tested pair are faulty. The Küpfmüller method consists of 2 measurements:   ■ First measurement with open far end   ■ Second measurement with strap on the far end  The result of Küpfmüller measurement is: Lx/L In addition ECFL 30 provides:   ■ RL loop resistance   ■ FaE and FbE insulation resistances   ■ Rx resistance to fault ■ Lx distance to fault The conditions of accurate results:  ■ Ia and Ib < 450 uA  ■ Ф wire a=Ф wire b  ■ 0,5>FaE / FbE>2  ■ FaE + FbE>100 x R loop ELEKTR NIKA

4 3-Point Method ELEKTR NIKA
Recommended when the gauge of wires in a pair are different (two healthy auxiliary wires are necessary) The 3-Point method consists of 3 measurements:   ■ First measurement when the measuring voltage is connected to wire a   ■ Second measurement when the measuring voltage is connected to the ground   ■ Third measurement when the measuring voltage is connected to wire c The result of 3 Point measurement is: Lx/L In addition EFL 10 provides:   ■ RL loop resistance   ■ FaE insulation resistance   ■ Rx resistance to fault ■ Lx distance to fault The conditions of accurate results:  ■ Ia and Ib < 450 uA ■ The insulation resistance of auxiliary wires must be thousand time as high than that of the faulty one.   ELEKTR NIKA

5 Resistance Difference Measurement
EFL 10 provides the following results: Ra, Rb, Rloop, Δ R, % ELEKTR NIKA

6 Capacitance Unbalance Measurement
EFL 10 provides the following results: CaE, CbE, ΔC nF, Δ % ELEKTR NIKA

7 THANK YOU FOR YOUR ATTENTION!