Meshed DC networks for offshore wind development

Slides:



Advertisements
Similar presentations
CONDITIONS FOR SUCCESSFUL INTERRUPTION:
Advertisements

Grid Connect Inverters NUER 19
High Voltage Direct Current(HVDC)
1 Wyoming Infrastructure Authority November 10, 2009 Superconductor Electricity Pipelines.
Black Sea Energy Conference Bucharest April 3-5 Bo Normark
HIGH VOLTAGE DIRECT CURRENT TRANSMISSION
1 POWER QUALITY -- Bhanu Bhushan -- June, How close is the supply voltage waveform to sinusoidal, and how close are the supply voltage and frequency.
Study Committee Representatives Annual Report December, 2012
Tore Langeland, Yongtao Yang and Carl Öhlen Risk based approach for development of offshore HVDC transmission technologies EWEA 2012.
OFFSHORE RENEWABLE PLANT HVDC POWER COLLECTOR AND DISTRIBUTOR
© ABB Group May 1, 2015 | Slide 1 Large scale integration of Offshore Wind Power Design Considerations Peter Sandeberg /ABB, EOW 2009,
Click to edit title Click to edit sub-title The European Network of Transmission System Operators Stockholm 14th of September 2009 Teun van Biert - Convener.
Brief on HVDC 2015 Brief on HVDC 2015
A review of offshore wind power grid connection options in the Bothnian Bay Offshore grids for wind power integration Sisu Niskanen VTT Technical Research.
The Integration of Renewable Energy onto the Existing Grid Dr Norman MacLeod Technical Director, HVDC.
1 Study Committee Representatives Annual Meeting October 4, 2009 Toronto SC B4 “HVDC and Power Electronics” Activity Report Presented by: John McNichol.
Protection notice / Copyright noticeFor presentation in EWEC 2010 HVDC Solution for Offshore Wind Park Comprising Turbines Equipped with Full-Range Converters.
© ABB-EWEC 2006 ATHENS /03/06 EWEC 2006 Athens The Challenges of Offshore Power System Construction Peter Jones Lars Stendius ABB.
EStorage First Annual Workshop Arnhem, NL 30, Oct Olivier Teller.
HVDC-LIGHT Technology
© ABB Group August 7, 2015 | Slide 1 Variable Shunt Reactors Optimize Transmission Systems Dr. Claes Bengtsson, Global Product Manager, Reactors. PowerGen.
© ABB SG_Presentation_rev9b.ppt | 1 © ABB SG_Presentation_rev9b.ppt | 1 Smart Grid – The evolution of the future grid Karl Elfstadius,
Master in Advanced Power Electrical Engineering © Copyright 2005 Techno-economic aspects of power systems Ronnie Belmans Dirk Van Hertem Stijn Cole.
(Associate Professor)
Stephan Meier, Staffan Norrga, Hans-Peter Nee
Year 2006 Report “Better” Managed and Controlled Transmission Grids using Advanced Technological Concepts Aty Edris EPRI Power Delivery & Markets
6/10/2003 – e.heineVLVnT facility-power1 EFNI H K Introduction Hypothesis Topology, technical constrains Redundancy, budget constrains Grounding Reliability.
THE TRES AMIGAS SUPERSTATION Southwest Renewable Energy Conference Santa Fe, NMSeptember 16 th 2010 UNITING THE NATION’S ELECTRIC POWER GRID.
Ronnie Belmans Florence, 5 November 2010
HIGH VOLTAGE DC TRANSMISSION by Muhammad Sarmad Hafeez
Europe goes Offshore with Wind Farms Hermann J. Koch Senior Member IEEE Substations Committee Vice Chairman Siemens Energy Sector Transmission Erlangen,
HVDC LIGHT TECHNOLOGY BY: D.SINDHUSHA G.SOWJNAYA B.MEHER DIVYA GMRIT.
THYRISTOR BASED FACTS CONTROLLER
23/04/2017 TITRE PRESENTATION 1.
 Transmitting power at high voltage and in DC form instead of AC is a new technology proven to be economic and simple in operation which is HVDC transmission.
1 Study Committee Representatives Annual Meeting October 19, 2008 Winnipeg SC B4 “HVDC and Power Electronics” Activity Report Presented by: John McNichol.
© ABB Power Technologies :\PTP\GF-CC\Arbetsmaterial Jan-16 HVDC Light – ABB’s technology for invisible transmission Per Haugland Head of ABB Power.
Recent TSO report on changes because of larger amounts of renewable enery IEA Task 25, January 14, 2016 Edf – Clamart – Paris – France Lennart Söder Professor.
Efficient Energy Transmission using HVDC
“HVDC TRANSMISSION” SUNIT KUMAR SAHOO REG NO-S BRANCH-EEE PREPARED BY.
Overview OF MULTI Mega Watt WIND TURBINES and wind parks
HVDC Transmission.
CLOSED LOOP SPEED CONTROL OF DC MOTOR WITH PWM TECHNIQUE
RECENT TRENDS IN POWER SYSTEMS
HVDC TRANSMISSION Under Guidance Dr. Shahnaz Ayub Er.Kamini Prajapati Submitted By Mayank Kumar
© ABB Group October 1, 2016 | Slide 1 DynaPeaQ ® SVC Light ® with Energy Storage FACTS.
 The common type of wind power generators are squirrel cage induction generator (SCIG),doubly fed induction generator (DFIG)  For more secure and.
HVDC and its System Benefits
ELEC-E8422 Introduction to Electrical Energy Systems
Introduction to Electric Power System and A. C. Supply
Devices used for Grid scale AC-DC and DC-AC power conversion
1 3 Earths will be required by 2050.
A Project Review On POWER QUALITY IMPROVEMENT IN GRID USING STATECOM
HVDC LIGHT:- NEW TECHNOLOGY FOR A BETTER ENVIRONMENT
FACTS BY SVC, FLEXIBLE AC TRANSMISSION
High Voltage Engineering High Voltage Direct current (HVDC)
IG BASED WINDFARMS USING STATCOM
Study Committee Representatives Annual Meeting October 18, 2010 Winnipeg SC B4 “HVDC and Power Electronics” Activity Report Presented by: John McNichol.
ARYA INSTITUTE OF ENGINEERING & TECHNOLOGY
Wind turbine technology
Transmission Solutions
HVDC Transmission part 2. Types of HVDC links: Monopolar link Bipolar link Homopolar link.
Five level diode clapmed inverter
Novel Protection Schemes for HVDC System
HVDC Transmission Systems:
Evaluation of wind farm layouts
High Current Direct Current (HCDC) Superconductor Cable
Use of Real-Time Simulation in the Caithness-Moray HVDC Transmission Project Dr. Oluwole Daniel Adeuyi 10th April 2019 Keynote Presentation at the 4th.
FACTS BY SVC, FLEXIBLE AC TRANSMISSION
ENG. Julius Ndirangu and
Presentation transcript:

Meshed DC networks for offshore wind development Ronnie Belmans KULeuven ESAT-ELECTA ronnie.belmans@esat.kuleuven.be / May-2010

ronnie.belmans@esat.kuleuven.be / May-2010 Overview Historical development of HVDC → can we stretch to ‘supergrids’? VSC HVDC Offshore Wind applications Multi-terminal Challenges for offshore Multi-terminal Direct Current (MTDC) systems How to connect to AC grid ronnie.belmans@esat.kuleuven.be / May-2010

ronnie.belmans@esat.kuleuven.be / May-2010 Supergrid: Why? Harness RES, crucial role of offshore wind, but also wave, tidal and osmotic energy. Balancing: wind - hydro - natural gas Connect remote energy sources Trading: single market ronnie.belmans@esat.kuleuven.be / May-2010

Planning How will the future grid look like? Can we manage by stretching the current 380 kV grid to its limits? Or do we need a new overlay grid? “Stretching” was successful for trains Be aware of the “sailing ship syndrome”… We must accept the limits of today’s situation ronnie.belmans@esat.kuleuven.be / May-2010

Planning: How will the future grid look like? 1956 1948 A renewed grid vision? 1974 2008 ? 2020 2050 … ronnie.belmans@esat.kuleuven.be / May-2010

Supergrid Visions How will the future DC grid look like? source: www.airtricity.com ronnie.belmans@esat.kuleuven.be / May-2010

Supergrid Visions How will the future DC grid look like? Hydro power Solar power Wind power DC transmission 99LFC0825 Wind 300 GW 25 000 km sq 5000 x 10 km Hydro 200 GW Cables (Solar) 140 pairs of 5 GW and 3000 km each Solar 700 GW 8000 km sq 90 x 90 km © ABB Group Slide 7 10MP0458 ronnie.belmans@esat.kuleuven.be / May-2010

Supergrid Visions How will the future DC grid look like? http://www.desertec.org G. Czisch http://www.mainstreamrp.com/pages/Supergrid.html ronnie.belmans@esat.kuleuven.be / May-2010

Supergrid Visions How will the future DC grid look like? wind-energy-the-facts.org mainstreamrp.com pepei.pennnet.com Statnett wikipedia/desertec Desertec-australia.org Statnett © ABB Group Slide 9 10MP0458 ronnie.belmans@esat.kuleuven.be / May-2010

Electricity pioneers: AC or DC? DC is not new Direct Current DC Generator built by W. von Siemens and Z.Gramme Low line voltage, and consequently limitation to size of the system Edison Alternating current AC Introduced by Nikola Tesla and Westinghouse Transformer invented by Tesla allows increasing the line voltage Allows transmitting large amounts of electricity over long distances Work of Steinmetz ronnie.belmans@esat.kuleuven.be / May-2010

Thury System HVDC is not new either Thury system: series connected DC generators and loads 1889: first system (1kV) 1906: Lyon-Moutiers (125 kV, 230 km) 1913: 15 Thury systems in use Problem: reliability (series connection) ronnie.belmans@esat.kuleuven.be / May-2010

ronnie.belmans@esat.kuleuven.be / May-2010 AC/DC Conversion AC became prevalent Full DC electricity grid out of the question. HVDC needed AC/DC conversion Research and development effort on Mercury Arc Valves in 20’s 40’s First HVDC project completed in 1955: Gotland Steady increase in ratings ronnie.belmans@esat.kuleuven.be / May-2010

ronnie.belmans@esat.kuleuven.be / May-2010 Semiconductors Advances in semiconductors led to thyristor valves with many advantages Simplified converter stations Overhauls less frequently needed No risk of mercury poisoning Easy upscaling by stacking thyristors (increased voltage levels) and parallel-connecting thyristor stacks (increasing current rating) Gradual replacement of mercury arc valves to thyristor valves. First replacement 1967: Gotland Today only 1 or 2 HVDC systems with mercury arc valves remain ronnie.belmans@esat.kuleuven.be / May-2010

ronnie.belmans@esat.kuleuven.be / May-2010 Highlights Pinnacle: Itaipu 1984 - 1987: ±600 kV, 2 x 3150 MW First multi-terminal: 1987 800 kV Shanghai-Xiangjiaba (2011), LCC HVDC world records: Voltage (800 kV) Transmitted power (6400 MW) Distance (2071 km) ronnie.belmans@esat.kuleuven.be / May-2010

ronnie.belmans@esat.kuleuven.be / May-2010 Scheme Converter transformers Large inductor Filters valves ronnie.belmans@esat.kuleuven.be / May-2010

Operation: LCC or CSC HVDC Ud 6-pulse bridge LCC: Line-Commutated Converter → needs grid to commutate CSC: Current Source Converter ronnie.belmans@esat.kuleuven.be / May-2010

LCC HVDC Reactive Power Requirements 1,0 0,5 I d Q Classic Shunt Banks filter Harmonic Filters 0,13 converter source: ABB unbalance LCC converters absorb reactive power (50% to 60% of active power). Harmonic filters needed to filter AC harmonics and to provide reactive power. The more active power, the more reactive power is needed Switching filters to reduce unbalance ronnie.belmans@esat.kuleuven.be / May-2010

ronnie.belmans@esat.kuleuven.be / May-2010 CSC HVDC Filter requirements result in huge footprint Not viable for offshore application ronnie.belmans@esat.kuleuven.be / May-2010

Multi-terminal Hydro Québec - New England (1992) Extended to 3-terminal Originally planned: 5-terminal but cancelled (Des Cantons, Comerford) Fixed direction of power ronnie.belmans@esat.kuleuven.be / May-2010

Multi-terminal Mainland Italy-Corsica-Sardinia 1965: monopolar between mainland and Sardinia 1987: converter added in Corsica 1990: mercury arc replaced by thyristors 1992: second pole added ronnie.belmans@esat.kuleuven.be / May-2010

Multi-terminal Mainland Italy-Corsica-Sardinia Corsica converter is parallel tap Limited flexibility, e.g.: fast change in power flow direction at Sardinia requires temporary shut-down of Corsican converter Conclusion from Hydro Québec - New England and Mainland Italy-Corsica-Sardinia: Multi-terminal HVDC? Not really! ronnie.belmans@esat.kuleuven.be / May-2010

Intermediate Conclusion 1 Footprint too large because of filtering requirements There is no offshore voltage source, needed for commutation General multi-terminal operation not feasible, only ‘pseudo-multi-terminal’ CSC for offshore multi-terminal HVDC is a dead end ronnie.belmans@esat.kuleuven.be / May-2010

ronnie.belmans@esat.kuleuven.be / May-2010 VSC HVDC Not new development, but entirely new concept based on switches with turn-off capability Characteristics: No voltage source needed to commutate Very fast Very flexible: independent active and reactive power control ronnie.belmans@esat.kuleuven.be / May-2010

ronnie.belmans@esat.kuleuven.be / May-2010 VSC HVDC First installation: Gotland (yes, again) 1999 50 MW ±80 kV Subsequent installations have ever higher ratings, but ratings CSC remain out of reach ronnie.belmans@esat.kuleuven.be / May-2010

ronnie.belmans@esat.kuleuven.be / May-2010 State-of-the-art Existing VSC HVDC 350 MW ±150 kV DC 180 km CSC HVDC 6300 MW ±600 kV DC 785 km + 805 km Currently possible CSC HVDC 6400 MW ±800 kV DC 2000 km VSC HVDC 1100 MW 350 kV DC ronnie.belmans@esat.kuleuven.be / May-2010

ronnie.belmans@esat.kuleuven.be / May-2010 VSC Scheme Large capacitor ronnie.belmans@esat.kuleuven.be / May-2010

VSC Switching Two possibilities PWM Multi-level ronnie.belmans@esat.kuleuven.be / May-2010

VSC HVDC Reactive power requirements Reactive power can be provided by converter Operation in four quadrants possible Voltage support Smaller filters: only for filtering, not for reactive power -1,2 -1,0 -0,8 -0,6 -0,4 -0,2 0 0,2 0,4 0,6 0,8 1,0 1,2 Q (pu) 1,2 1,0 0,8 0,6 0,4 0,2 -0,2 -0,4 -0,6 -0,8 -1,0 -1,2 P (pu) Inductive Capacitive ronnie.belmans@esat.kuleuven.be / May-2010

ronnie.belmans@esat.kuleuven.be / May-2010 Construction Less filters → reduced footprint Only cooling equipment and transformers outside Valves pre-assembled ronnie.belmans@esat.kuleuven.be / May-2010

VSC HVDC for offshore applications Modified design for offshore applications Troll (2005) First offshore HVDC converter 40 MW, 70 km from shore Oil-platform ronnie.belmans@esat.kuleuven.be / May-2010

VSC HVDC for offshore applications Valhall (2010) 78 MW 292 km Oil-platform ronnie.belmans@esat.kuleuven.be / May-2010

VSC HVDC for offshore applications Borwin alpha (2010) First offshore HVDC converter for wind power 400 MW 200 km Wind collector ronnie.belmans@esat.kuleuven.be / May-2010

ronnie.belmans@esat.kuleuven.be / May-2010 Borwin alpha AC side with transformers, breakers, and filters AC phase reactors Valves DC side with capacitors and cable connections Cooling equipment ronnie.belmans@esat.kuleuven.be / May-2010

VSC HVDC for wind applications No cable length issues Wind farms are independent of power system Do not need to run on main frequency Do not need to run on fixed frequency Wind farm topology must be re-evaluated (fixed speed induction machines?) Multiple wind farms can be connected to offshore grids This could lead to a ‘supergrid’ connecting different areas with different wind profiles ronnie.belmans@esat.kuleuven.be / May-2010

Offering Ancillary Services to the Grid TSO’s Grid Code: “Wind turbines must have a controllable power factor” Grid code country- specific Demands at PCC for 300 MW Minimum PF = 0,95 Required: 98,6 MVAr Capacitive limit Inductive limit ronnie.belmans@esat.kuleuven.be / May-2010

Offering Ancillary Services to the Grid Additional equipment needed such as SVC, STATCOM,… Compensate AC cable capacitance Be grid compliant Resonances between cable C and grid L ronnie.belmans@esat.kuleuven.be / May-2010

Reactive power control by VSC HVDC P,Q-controllability of onshore converter No additional components (STATCOM, SVC) needed ronnie.belmans@esat.kuleuven.be / May-2010

Multi-terminal VSC HVDC VSC HVDC only developed for point-to-point, but… …looks very promising for MTDC Converter’s DC side has constant voltage → converters can be easily connected to DC network. Extension to ‘pseudo-multi-terminal’ systems straightforward: e.g. star-connections ronnie.belmans@esat.kuleuven.be / May-2010

Intermediate Conclusion 2 Footprint can be made small enough for offshore applications because of limited filtering requirements No offshore voltage source needed Offshore operation is proven for point-to-point connection General multi-terminal operation possible because DC side has constant voltage VSC for offshore multi-terminal HVDC looks promising ronnie.belmans@esat.kuleuven.be / May-2010

Challenges for supergrid Technical Offshore equipment Ratings Losses Reliability MTDC Control Economical/Financial Political/Sociopolitical ronnie.belmans@esat.kuleuven.be / May-2010

ronnie.belmans@esat.kuleuven.be / May-2010 Challenges Losses Converter losses very high (> 1.3%) Special switching techniques New materials Cooling Ratings Proven power ratings low compared to CSC HVDC Proven voltage levels low compared to CSC HVDC ronnie.belmans@esat.kuleuven.be / May-2010

ronnie.belmans@esat.kuleuven.be / May-2010 Challenges Reliability DC Fault leads to complete shutdown To protect IGBTs from fault current, they are blocked Anti-parallel diodes keep conducting the fault current No DC breakers are present The fault needs to be cleared by opening AC breakers For MTDC, a DC fault would lead to loss of whole MTDC grid. This is not acceptable. The fault needs to be cleared selectively at DC side. Problem DC breaker not available yet Current rises extremely fast Very fast fault detection needed Very fast and precise fault localisation needed Very fast breaker needed ronnie.belmans@esat.kuleuven.be / May-2010

ronnie.belmans@esat.kuleuven.be / May-2010 Challenges Reliability DC voltage needs to remain within small band Problem: If only one converter controls DC voltage, DC voltage can become unacceptably low in MTDC grid What if voltage controlling converter fails? Other voltage control method needed. Which one? Unknown. ronnie.belmans@esat.kuleuven.be / May-2010

ronnie.belmans@esat.kuleuven.be / May-2010 Example Slack converter (controls DC voltage) ronnie.belmans@esat.kuleuven.be / May-2010

ronnie.belmans@esat.kuleuven.be / May-2010 Example Loss of converter ronnie.belmans@esat.kuleuven.be / May-2010

ronnie.belmans@esat.kuleuven.be / May-2010 Example Slack converter compensates 200 If 200 is higher than converter rating, DC voltage will become unacceptably high ronnie.belmans@esat.kuleuven.be / May-2010

ronnie.belmans@esat.kuleuven.be / May-2010 Challenges Economical/Financial issues Different generation and load scenarios Cost/benefit of scenarios Electricity prices Financial demand per scenario Realization and ownership of the Supergrid European funding Potential investors Source: ENTSO-E, “Ten-year network development plan 2010-2019” ronnie.belmans@esat.kuleuven.be / May-2010

ronnie.belmans@esat.kuleuven.be / May-2010 Challenges Political/Sociopolitical issues Legal and regulatory framework Social acceptance of the Supergrid Permitting processes, harmonization of national rules European policy on DSM New areas to be incorporated: Russia, Nordic,… Political stability of regions Risk of terrorist attacks Source: ENTSO-E, “Ten-year network development plan 2010-2019” ronnie.belmans@esat.kuleuven.be / May-2010

ronnie.belmans@esat.kuleuven.be / May-2010 Challenges Other Technical compatibility Incentive mechanisms for TSOs Common, long term vision Planning … ronnie.belmans@esat.kuleuven.be / May-2010

ronnie.belmans@esat.kuleuven.be / May-2010 Connection to AC grid Connection to AC grid Close to shore Reinforcement AC grid needed OHL AC Underground AC cable To strong, inland AC bus Overhead DC Underground DC ronnie.belmans@esat.kuleuven.be / May-2010

ronnie.belmans@esat.kuleuven.be / May-2010 Sea vs Land cable Land cable Light: weight limits maximum section length. Less joints needed Small bending radius: smaller drums can be used Easy installation No armour ronnie.belmans@esat.kuleuven.be / May-2010

ronnie.belmans@esat.kuleuven.be / May-2010 Sea vs Land cable Sea cable Heavy Transported by ship in very long sections Large bending radius: huge, ship-mounted drums Armoured by galvanised steel Water tight by lead sheaths ronnie.belmans@esat.kuleuven.be / May-2010

ronnie.belmans@esat.kuleuven.be / May-2010 AC vs DC cable AC cables Three-phase → three conductors Reactive compensation at regular intervals DC sea cable more expensive than DC land cable AC cable more expensive than DC cable ronnie.belmans@esat.kuleuven.be / May-2010

Cost ratio ac / VSC HVDC (2006) Factors: DC sea cable more expensive than DC land cable AC cable more expensive than DC cable Conclusion: If underground solution is needed, HVDC may be cheaper ronnie.belmans@esat.kuleuven.be / May-2010

ronnie.belmans@esat.kuleuven.be / May-2010 Example: Borwin 128 km DC sea cable 75 km DC land cable (less expensive) ronnie.belmans@esat.kuleuven.be / May-2010

ronnie.belmans@esat.kuleuven.be / May-2010 Example: Borwin ronnie.belmans@esat.kuleuven.be / May-2010

ronnie.belmans@esat.kuleuven.be / May-2010 Conclusions CSC HVDC Stretching not possible Too large Grid voltage needed VSC HVDC Stretching possible Small footprint Passive grid operation Technical characteristics suited to wind applications Offshore applications proven Technical challenges remain… DC breaker Fast fault detection and localisation Losses Ratings DC voltage control …but can be solved Need to further look into economical and political challenges ronnie.belmans@esat.kuleuven.be / May-2010