Suparule Cable Height Meter: A guide

Slides:



Advertisements
Similar presentations
As a stand-alone overview of test tools.
Advertisements

Electricity Chapter 13.
Product Presentation. WHAT IS IT? Product Presentation.
How to use the NEC projector Its easy! Really!. How to use the NEC projector IMPORTANT-make sure you have reserved the equipment (projector and/or laptop).
3/17 Dividend Street, Mansfield, 4122, Queensland, Australia phone: web: The SuperCycler A Software.
5.2 Costs and Revenues IBBM.
F&T Inc. OVERHEAD CRANE SAFETY.
Solid level measurement
Water Quality Testing Made Easy GPS Aquameter and Multiparameter Aquaprobe The perfect solution for your water quality testing needs.
John Ogilvie High School - CfE Physics
SECTION 11 LEVEL B SUIT OUT. SECTION 12 AIR MONITORING.
DOPPLER TROUBLE SHOOTING 2013 WEBINAR WEBINAR TECH SUPPORT.
SOLARIS 3-GAS METER Complete operation of Solaris multi-gas meter can be found on the LAFD Ethernet.
P1 Revision Examination Style Questions
Electricity in Offices Topics 2 Electricity consumption 3 Energy saving attitude 4 Replacing old office technology 5 Power management 7 Working habits.
DP-IR Detecto-Pak Infrared
Olympus DM-20 Digital Voice Recorder We’re high tech now, baby!
Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
CommentaryVideo Hi, my name is Edward Guillergan and I’m one of AMETEK Programmable Power’s Applications Engineers. I’m here to provide an overview of.
Copyright Health Promotion Board
Chapter 9 Radio Maintenance MComm – Ch Confidence Testing Preventive Maintenance Corrective Maintenance Summary Overview MComm – Ch9 - 2 >>
TLA. Replacing The Battery On the Back of the pager press in this button while moving the door away from the pager, then lift up. On the Back of the pager.
They’re fast, they’re easy to use, and they fit on your tool belt. Why the Fluke 416D and Fluke 411D? Use Fluke distance meters to quickly determine an.
1 Check all equipment is included before returning. If you have an accident or the equipment is damaged or you need support please contact Blaize
Motors and Automatic Target Recognition Motors... l Motorized Instruments have 2 Motors: –One to Rotate the Alidade Horizontally –A Second to Rotate.
SupaRule Cable height meters Presented by: Gary Carroll Director Feb 2004.
If you use your computer more than a few hours per day, we suggest you not to turn off your computer at the end of the day. Instead turn off only the.
EPOCH 1000 Series Procedure Phase Array Straight Beam Calibration
AquaGlo Water Detector Kit For Detecting Water in Jet Fuel
1Rugby 55 Presentation – January 2007 The Rugby 55 User Presentation.
S.H.H.S Building Construction
Data Logging GCSE ICT. Learning Intentions: To explore the tern data logging. To explore the concept of analogue and digital data and the need for conversion.
GPS. Meet the Bad Elf GPS Pro The Bad Elf GPS Pro offers the first Apple approved GPS with an informative user interface.
TIRE PRESSURE MONITORING SYSTEMS
January 2011City of Boise 1 City of Boise Time Clock Training Airport Biometrics Clocks.
Canon Digital REBEL XTi ITS HELP DESK INFORMATION ON CAMERA CARE.
10 Energy Saving Advices. 1- Lowering of the temperature at night Limit the lowering of the temperature at night. If the temperature is reduced too much,
CARE OF THE GUITAR, PLAYING POSITION. CHECK FOR BINDERS, TABS, NOTEBOOK PAPER.
Cypress-Fairbanks I.S.D. 04/04/05 PC6 Word Processor Training Assistive Technology
Goal: To understand Electrical Currents Objectives: 1)To understand The flow of charge 2)To understand Voltage. 3)To understand Resistance and Ohm’s Law.
1Rugby 50 Presentation – January 2007 The Rugby 50 User Presentation.
Nokia Bluetooth Headset BH-108 for Contact Centers
Program ultrasonic range sensor in autonomous mode
COMPUTER CARE & MAINTENANCE. Protecting Your Computer From Damage Like any kind of equipment, your computer requires care and maintenance to run smoothly.
I.C. ENGINES Practical No: 1 (17 Mar, 2014). Measurement of Cylinder Pressure If your vehicle has been running roughly or losing power, there may be a.
Toby Shoobridge David Benham NERC Space Geodesy Facility Herstmonceux, UK
1 Work Orders. 2 Generating a Work Order There are two methods to generating a Work Order in the WYNNE STSTEM. First method: Option 11 – 12 – 13 * Open.
Globe Protocol By The ECH2O Academy Junior Class of
 Today's vehicles are much more complex and complicated than the cars of the 1960s, '70s, '80s, incorporating more computer electronics, silicon chips,
Using a Digital Data Logger North Carolina Immunization Program (NCIP)
National Highway Institute 5-1 REV-2, JAN 2006 EQUIPMENT FACTORS AFFECTING INERTIAL PROFILER MEASUREMENTS BLOCK 5.
MSA Passport  Personal Alarm Combustible gases and vapors Oxygen enriched Oxygen deficient Specific Toxic gases Alarm levels are set at the factory.
TIRE PRESSURE MONITORING SYSTEMS
Quick Start Guide for Flex Flow Pump
Taking Measurements in Science
CA05FS Owner’s Manual Fuel Cell Technology Breath Alcohol Tester.
Data Logging & Control Systems
Visit for more Learning Resources
Sensors May 25, 2013.
Module – Groundwater Level Measurement
Crane safety and inspections
Data Logging GCSE ICT.
Data Logging GCSE ICT.
Crane safety and inspections
Manual D Duct Sizes Room Cooling CFM % Total CFM Heating CFM Kitchen GR Dining Bed Bed 3.
Leveling By : Parveen Kumar.
Crane safety and inspections
Crane safety and inspections
Instruments & Electrical Measurements Lecture 4
AquaGlo Water Detector Kit For Detecting Water in Jet Fuel
Presentation transcript:

Suparule Cable Height Meter: A guide Jan 2012

Suparule Cable Height Meters Cable Height Meter – an ultrasonic device to check wire clearance to ground and spacing of overhead conductors. Key Features: Safest - no contact with conductors/wire Simple -  One button- one man operation Easy to use - stand underneath, press the button, and read the measurement Fast - measurements in seconds Accurate - less than 0.5% error in reading

Why was the CHM developed? Low wires are a public safety problem Many reported accidents with both electrical and telecom wires Existing measuring methods were not considered safe enough for operators

Competitive Instruments Laser type surveying equipment. (Very expensive, and not application specific) Fibre-glass hot sticks (frequently breaks, conveys electricity if dirty/wet) Optical device (inaccurate, cannot differentiate between conductors) No real competitive instrument to the CHM

Ultrasound Measurement From the cone of instrument, the transducer sends out a burst of sound The sound ‘bounces’ off the cable, and need to be received in cone, as transducer is at the same time transmitter & receiver. The CHM clocks the amount of time taken Calculates distance, based on speed of sound. Adjusts for air temperature. The microcontroller calculates the distance in either imperial or metric Instrument Time Echoes from wires

How to use of Cable Height Meter      CHM Operation  1. Select: M (metric) or I (imperial) at the back 2. Set the CAL mode switch to the WIRE position. 3. Press the ON key to power 4. Stand directly underneath the conductors(s) to be measured. 5.  Press the MEASURE Key to take measurement. Press the READ key to display each of the stored wire height differences (Stored Measurements).

Cable height meter: CAL (Calibration) Mode The CAL mode switch allows the user to periodically check the unit, to ensure that it is still operating within specification. For cable height measurement, this switch should be in the WIRE position. When the switch is put to the WALL (CAL) position horizontal measurements to large objects, e.g. walls, can be taken. When the unit is first used, a horizontal reading to an object, e.g. wall, from a fixed position should be taken. The reading should be recorded, together with the date. Whenever the unit is to be checked for accuracy, a reading should be taken from the same point, noting the result and date. If the reading is outside of specification, the unit should be returned to Suparule. Date Readings

Range Specification of the CHM 190-300-600 measures up to 15m (50ft)

Range Specification of the CHM 300E-600E measures up to 23m (75Ft)

Cable height meters: Model choice CHM models 300 300E 600 600E Range (25mm cable min) 3 –15m (10-50ft) 3 –23m (10-75ft) Range (12mm cable min) Range (5.5mm cable min) 3 –12m (10-40ft)   Range (2.5mm cable min) 3 –10m (10-33ft) No. of wires measured 3 6

Just simply stand under the O/H line, center yourself under the conductors and press the button.

Reading #1 gives the height to the lowest conductor

Reading #2 gives the distance between 1st and 2nd wire

Reading #3 gives the distance between 2nd and 3rd wire

Reading #4 gives the distance between 3rd and 4th wire

The memory stores the measurements so that you can scroll through them in order to record them on paper etc.

By pressing button once, readings of up to 6 conductors are taken provided the wires are all within the ultrasonic beam

CHM & Ultrasonic beam Push Measure button once, provided wires are within the ultrasonic beam. If not, take a number of readings underneath each of the wire. Make sure the cone is perpendicular to overhead wire, as otherwise reflection will not be received in cone.

CHM Accuracy : Error typically less than 0.5% +/-2digits If the actual distance being measured is 5m, tolerance of +/-0.5%, the CHM will give a reading between 4.975m and 5.025m The Number of digits specification is an extra tolerance on the display reading. 2 digits = 10mm. The +2d specification therefore means that a further +/-10mm can be added to the display reading, i.e. 4.965m and 5.035m. Accuracy is met when CHM is regularly calibrated. Best practice require a 12 month calibration.

CHM Battery Battery Life 50,000 measurements Battery used: 9V, PP3, non-rechargeable, Alkaline, Long-life (>600mAH) The cable height meters automatically switch off after 3mn if no buttons are pressed to save battery. When battery is low, a low battery warning symbol pop up on screen: Need to change the battery.

Do & Don’t with CHM Do’s: Don’ts: · Position the unit on the ground, directly underneath the conductor(s) to be measured. · Align the unit in the direction of the conductor, with the cone pointing towards the conductor(s). · The ultrasonic waves need to be sent and received in the cone, so alignment is important. · Keep the unit dry; if it does get wet, leave it upside down in a warm area · The unit will work in a humid environment; however, if water gets into the electronics, long-term damage can occur. Don’ts: · Avoid clutter. Too many branches/leaves could confuse the unit, as the ultrasonic waves will bounce back from any obstacles. · Avoid water. It can damage the electronics · Avoid sudden changes of temperature. The Cable Height Meter takes into account temperature to measure the speed of sound travelling in air. If there are sudden temperature changes, i.e. from a warm car in winter to cold icy ground, leave the unit to adjust for a few minutes.

Suparule Cable Height Meters : Get the most out of CHMs Let temperature settle, otherwise incorrect reading is displayed. Press measure button until reading is stable. Unit needs to get a clear/clean echo back, to calculate correct distance. Make sure echo gets back into cone, as otherwise, unit will not display reading. May need to tilt unit to get a reading if overhead wires are sloped. CHM is not waterproof, so keep unit dry as much as possible. If wet, leave it in a warm place upside down, until dry. Regular calibration a must to get best accuracy

Who uses the CHM? Planners Safety Officers Line Managers Linesmen / Installers Contractors Haulage companies Regulatory Inspectors

Warranty & Repair The CHM is covered by a 24 month warranty on all parts and labour Any defective instrument will be replaced free of charge during this period Damaged or broken instruments will be repaired and charged at cost Each instrument is pre-set, and calibrated at Suparule Service contract available, please contact your distributor/suparule.

Suparule Cable Height Meters No better instrument for wire distance measurement Your key partner to safety Order NOW