INSULATION THICKNESS CALCULATOR. ENERGY EFFICIENCY PERFORMANCE PRINCIPLES THE BUILDING ENVELOPE Components that constitute the building envelope are:

Slides:



Advertisements
Similar presentations
What should you think about when deciding where to put your building? The direction a building faces will impact on a lot more than the view – how do you.
Advertisements

Dr. Ruth Collins TrinityHaus
Contents: Cover
Green Homes Click to edit Master title style Ferrier Builders, Inc. - Building Super Energy-Efficient Green Homes.
Passive house. Definition A Passive house is a buildings with good comfort conditions during winter and summer, without traditional space heating systems.
HEAT LOSS & HEAT GAIN HEAT FLOW. Heat flows from high temperature to low temperature There are 3 types/methods of heat flow/transfer: 1.Conduction- through.
  The Regulator (NRCS) has published legislation regarding energy efficiency in new buildings (NBR-XA)  Here’s what you need to know for your home.
Oslo, Norway Latitude: 59° 54' 36" N Longitude: / 10° 45' 00" E.
East Bridgford Project Existing Projects The Green Box Project Adaptation Techniques used within this project:- Natural ventilation is increased by a passive.
Energy Savings Impacts of the Advanced Energy Design Guide: Small Office Buildings Bing Liu, P.E. Research Engineer Pacific Northwest National Laboratory.
eQuest Quick Energy Simulation Tool
Q5- U-Value 2010 HL 5. (a) Calculate the U-value of an uninsulated external solid concrete wall of a dwelling house built in the 1950s given the following.
Building Energy Rating
Building Envelope. Energy Conservation House design and orientation Lifestyle changes Energy efficiency.
Heating and Air Conditioning I Principles of Heating, Ventilating and Air Conditioning R.H. Howell, H.J. Sauer, and W.J. Coad ASHRAE, 2005 basic textbook/reference.
Movable Insulation Jennifer Durham.  Usually insulation is used inside walls, ceilings, and floors to trap heat and create a thermal envelope.  Windows.
Chapter 5: Designing for Heating and Cooling 5.1 Organizing the problem a) Fenestration How much is optimum for the building? What should the form of the.
Heating energy calculation methods Anti Hamburg Lecture TTK-UAS.
IND 5615 – B UILDING S YSTEMS FOR I NTERIOR D ESIGNERS C ASE S TUDY : CHAPMAN GRADUATE SCHOOL OF BUSINESS Thermo Comfort: Heating & Cooling Systems A SSIGNMENT.
Energy, Environment and Buildings B FLOATING STUDENT RESIDENCE Evelyne Hornblower Yan Claprood April 2005.
Building Australia’s Future Energy Efficiency Introductory Awareness Training AUSTRALIAN Greenhouse Office Supported by: Step by Step Application of BCA.
By Emmi Miller and Jenny Sulouff
Passive Heating. Uses the energy from the sun to keep occupants comfortable without the use of mechanical systems.
Walls. Apply knowledge of thermal mass and insulation with passive design strategies to reduce the energy needed by active systems.
Passive Solar House A passive solar house is heated by the sun’s energy.
Windows Do not open or close all windows and doors at the same time. Optimise the ventilation by experimenting with opening different windows instead.
PASSIVE SOLAR DESIGN. Design Techniques
Brought to you by: Connecticut Energy Code Frederick F. Wajcs Senior Energy Engineer Northeast Utilities February 10, 2011.
MAIN ENTRANCE SOUTH EAST VIEW NORTH EAST VIEW.
Curtain Walling System Cladding System Insulation Panels.
Update on the SEEM Simulation Program Larry Palmiter and Ben Larson August 4, 2008 Ecotope Inc. Presented at Regional Technical Forum Portland, Oregon,
Conservation and Environmental Design and Construction
ARC 810: Building Climatology Department of Architecture, Federal University of Technology, Akure, Nigeria ARC 810: Building Climatology Department of.
Cost effectiveness Assume a $5000 system Pays itself off in 27 years if replacing a natural gas or oil hot water heating system 14 years if replacing or.
Development Management Department 1 of 49 ENERGY EFFICIENCY NATIONAL BUILDING REGULATIONS.
Heating Systems.
Energy Conservation February 8, Steve Wilson, MBA, CEM, CDSM, BEP The Energy Guy.
HVACR416 - Design Heat Loss / Heat Gain Part 1. Why? The primary function of Air Conditioning is to maintain conditions that are… o Conductive to human.
1 ISAT Module III: Building Energy Efficiency Topic 7: Transient Heating and Air Conditioning Loads  Thermal Admittance  Intermittent Heating 
Global Specialised Systems (KZN) (Pty) Ltd is an official supplier and installer of “Think Pink” Aerolite ceiling insulation for the last 30 years. South.
ARC 810: Building Climatology Department of Architecture, Federal University of Technology, Akure, Nigeria ARC 810: Building Climatology Department of.
1 Energy Efficient Housing. 2 Why construct energy efficient structures? Bottom Line !!! Money It may save up to 60% of the cost to heat/cool the structure.
Energy conservation strategies Buildings energy consumption depends on building envelop, efficiency of HVAC and lighting systems, amount of required fresh.
9. THERMAL MASS  Thermal mass is a measure of a material's capacity to absorb heating or cooling energy. Materials such as concrete or bricks are highly.
Site Location: Site Location: Gap Site at Bath Street and Pitt Street Plot: Plot: 50m x 50m Building Area: Building Area: 4000m 2 maximum Building Height:
Energy Design of Buildings using Thermal Mass Cement Association of Canada July 2006.
NEW SECTION - NATIONAL BUILDING LEGISLATION : NBR-XA - NATIONAL BUILDING STANDARD : SANS XA Part X : Environmental sustainability in buildings Part.
A New Language Shining the Light on Passive Solar Features and Retrofit Possibilities.
Building Envelope. Physical separator between interior and exterior spaces – Walls – Floors – Roofs – Fenestrations (any opening in the structure) – Doors.
4. INTERIOR LAYOUT  Good interior layout will facilitate many of the passive strategies recommended in this toolkit, in particular thermal mass, lighting.
ASSIGNMENT. Luanda, Angola Latitude: 8° 50' 18 S Longitude: 13° 14' 4 E.
Introduction to Energy Management. Lesson 4 Determining the Loads on the HVAC System.
Passive Solar Makes use of natural solar heating Requires buildings be designed to maximize the suns heating Most important element: face south (toward.
Solar Gain The ultimate free lunch!. Some Basics Why do we need to heat our homes? –Living rooms21 o C –Bedrooms18 o C –Staircases & halls16 o C.
Energy efficient windows for sustainable development Copyright of Wispeco (Pty) Ltd.
Heat transfer Steady state conditions not for dynamic systems in buildings through walls, roofs, floors, windows, doors building structures and U-values.
Heat Loss and Gain Civil Engineering and Architecture
Building Environmental Systems
Insulation Dr. Qing Wang
Passive Solar Design Elements
Studying Geothermal Heat Pump in Palestine
Heat.
Heat Loss and Gain.
Conduction Cooling Loads
FLOATING STUDENT RESIDENCE
Thermal Impact of Different Interior Finishing Materials on Energy Consumption YOGESH JATAV
Why we need to calculate heating load ?
Building standards Mr. Da Silva.
Passive Solar passive solar
Presentation transcript:

INSULATION THICKNESS CALCULATOR

ENERGY EFFICIENCY PERFORMANCE PRINCIPLES THE BUILDING ENVELOPE Components that constitute the building envelope are: 1.Roofs 2.Fenestration 3.Walls 4.Floors A well designed building envelope controls heat gain and loss in the hotter and colder seasons of the year. Maximize cooling air movement Limits exposure to direct sunlight in summer Trap and store heat from the sun in winter Minimise heat loss to the external environment

SECTIONAL ELEVATION OF A ROOM SHOWING EXTENT OF SUN PENETRATION AND HEAT LOSS/GAIN THROUGH THE BUILDING ENVELOPE

BUILDING REGULATIONS SANS 204 AND SANS 10400XA CORE ASPECTS OF THE STANDARDS ARE THE FOLLOWING: Site orientation Building orientation Shading Building design ( external walls, floors, fenestration, shading, roof assemblies and roof lights) Building sealing ( building envelope, air infiltration and leakage and permissible air leakages) Services (lighting and power, hot water services and appliances) Mechanical ventilation and air conditioning Installed equipment.

MAP OF CLIMATIC ZONES OF SOUTH AFRICA

FLOORS With the exception of zone 5 (climatic zones), buildings with a floor area of less than 500 m 2 with, a concrete slab on ground shall have insulation around the vertical edge of its perimeter which shall: Have an R-value of not less than 1.0 Resist water penetration in order to retain its thermal properties Be continuous from the adjacent finish ground level a) to a depth of not less than 300 mm b) for the full depth of the vertical edge of the concrete slab-on-ground Application criteria Table 1: Perimeter insulation required (mm) Climatic zone Minimum required R-values for perimeter insulation m 2 K/W

FLOORS Where an in-slab or in-screed heating system is installed it shall be insulated underneath the slab with insulation having a minimum R-value of not less than 1,0. Application criteria Table 2: installed under floor heating Climatic zone Minimum required R-values for perimeter insulation m 2 K/W

FLOORS With the exception of climatic zone 5, a suspended floor that is part of a buildings envelope shall have insulation that shall retain its thermal properties under moist conditions and be installed: For climatic zones 1 and 2, with partially or completely unenclosed exterior perimeter, and shall achieve a total R-value of 1,5 : For climatic zones 3, 4 and 6, with a partially or completely unenclosed exterior perimeter, shall achieve a total R-value of 1,0. With an in-slab heating system, and shall be insulated around the vertical edge of its perimeter and underneath with insulation having a minimum R- value of not less than 1,0. Table 3: suspended floor that is part of the building envelope Climatic zone Minimum required R-values for perimeter insulation m 2 K/W 1,5 11-1

FLOORS Detail 1: heat loss through un-insulated floor slabs and walls

FLOORS Detail 2: perimeter and under slab insulation

FLOORS Detail 3: perimeter and cavity insulation

FLOORS Detail 4: cavity insulation and under screed insulation

FLOORS Detail 5: suspended timber floor

EXTERNAL WALLS Non- masonry walls shall achieve a minimum total R-value of Climatic zones 1 and 6: 2,2 Climatic zones 2, 3, 4 and 5: 1,9 Application criteria Table 4: Light weight external walls surface density less than 180 Kg/m 2 deemed-to-satisfy minimum total R-Values for each climate Climatic zone Minimum required total R-values for light weight walls insulation m 2 K/W 2.21,9 2,2

EXTERNAL WALLS Masonry walls. For walls with a surface density greater than 180 kg/m2, table 5 sets out the minimum CR product requirements and their application: CR product –the time constant property (hours) of a composite element, such as a wall, and being the arithmetical product of the total C-value and the total R-value) The thermal capacity of a material is known as the C-value and it reflects the ability to store heat during the hot period and to radiate the heat during the cool period. This process is also known as thermal lagging, and masonry products such as bricks Application criteria Table 5: DEEMED TO SATISFY Minimum thermal capacity and resistance CR product, in hours, for external walling occupancies CR-Value per Climatic zone Residential: E1-E3, H1 –H Office and institutional: A1-A4, C1-C2, B1-B3, G Retail: D1-D4, F1-F3, J1-J Unclassified: A5, J4NR Note: NR= No requirement

EXTERNAL WALLS Detail 6: Wall insulation types

ROOFS AND CEILINGS A roof assembly shall achieve the minimum total R-value specified in table 6 for the direction of heat flow. Table 6 Minimum required R-Value (m 2.K/W) for Roofs Climatic zones Minimum required total R-values for roof solar absorptance of more than Dominant direction of heat flow.Up Down & Up UpdownUP

The tool kit is meant to support the decision making process that determines the use of insulation as energy-saving measures in new and existing buildings, with a focus of the three BASF insulation products (Neopor, Elastopor and Elastospray). This tool for determining recommended insulation levels is to be used in conjunction with other energy efficient design principles such as 1.Design for climate 2.Building orientation, main living areas towards the north 3.Insulation of geysers and pipes 4.Positioning of windows to allow cross ventilation and accommodate glass selection. BASF TOOL KIT

TOOL CONCEPTUAL CHART

TOOL LAYOUT

DETERMINING REQUIRED INSULATION THICKNESS Roof Construction Align with Climatic zone dial, Choose the climatic zone e.g. 2 Align with the minimum R-Values required from either the regulation or the rational calculations. See the required R- Value Match to the available R-values from Product manufacturer Product thickness mm

PLEASE TEST THE SAMPLE CALCULATOR