Cabling system components

Slides:



Advertisements
Similar presentations
IST 126 Transmission Media. Characteristics of Transmission Media Cost Ease of installation Bandwidth capacity – the amount of data that can be sent in.
Advertisements

Network Design Issues Design and Documentation Prepared by: Aline L. Mendoza.
Telecommunication Rooms
Making connections with Cat5 Way cool!
Cable Management.
Conducted and Wireless Media (Part I) School of Business Eastern Illinois University © Abdou Illia, Spring 2014 (February 26, 2014)
Introduction to Network
Confidential and proprietary materials for authorized Verizon personnel and outside agencies only. Use, disclosure or distribution of this material is.
ITNW 1325, Chapter III, Part II
Lecture 7 Cabling: Types and Termination
9-Jun-14Data Link Layer Guided Media Media that provide a conduit from one device to another. Signals travelling along any of these media is directed and.
Residential Telecommunications Infrastructure Standard
+ Straight-Through Cable Construction Lab 4. + Data Transmission In data transmission system, the transmission medium is the physical path between transmitter.
Cabling Structured Cabling Standards
Physical Transmission Media 8 5/9/ Modified by: Brierley.
TIA-1005 (Proposed by TR-42.9) Industrial Cabling Standard Pete Lockhart Anixter Manufacturing IT Forum Cleveland, Ohio May 20-21, 2008.
Guide to Network Cabling Fundamentals
CS335 Networking & Network Administration Thursday April 1.
111 © 2002, Cisco Systems, Inc. All rights reserved. Trim out phase steps Cutting cables to length Labeling cables Dressing cables Terminating cables Installing.
Classes of transmission media
Institute of Technology Sligo - Dept of Computing Many Roads To Home Paul Flynn.
1 Version 3.0 Module 3 Networking Media. 2 Version 3.0 Cable Specifications Cables have different specifications and expectations pertaining to performance:
Designing and Implementing Cabling Infrastructure Dr. Saif al Zahir King Fahd University of Petroleum & Minerals Computer Engineering Department Dr. Saif.
Click to edit Master subtitle style Chapter 3: Networking Topologies, Connectors and Wiring Standards Instructor:
1 Fiber Optics FIBER OPTIC PATCH PANELS. 2 Fiber Optics Just like our copper cable plant the fiber cable plant incorporates many of the same hardware.
Router. Switch Repeater Cable is the medium through which information usually moves from one network device to another. It used to connect one network.
Many Roads To Home. LAN Roads UTP STP Coaxial Fiber Optics.
Installing the Network Chapter 11 Release 16/7/2009.
Cisco – Semester 1 – Chapter 9 Preview Review. Behavioral Objectives Document all work –Do it as work proceeds –Same as chapter 8 guidelines –Don’t forget.
CSE 550 Computer Network Design Dr. Mohammed H. Sqalli COE, KFUPM Spring 2007 (Term 062)
Confidential and proprietary materials for authorized Verizon personnel and outside agencies only. Use, disclosure or distribution of this material is.
1 Telecom Cabling Patch panels, cabinets and raised floors.
The physical network Unit objective: Identify network cables and connectors, and use networking tools.
The Saigon CTT Semester 1 CHAPTER 9 Le Chi Trung.
Communication channels and transmission media
Physical Transmission Media Chapter 8. Objectives In this chapter, you will learn to: Identify the characteristics of wireline transmission Describe the.
Component 9 – Networking and Health Information Exchange Unit 2-2 Network Media and Hardware Communication Devices This material was developed by Duke.
HORIZONTAL SUBSYSTEM. CABLING SYSTEM Horizontal Subsystem The Horizontal cabling subsystem is the part of the Signamax Cabling System that extends from.
1 Guide to Network Cabling Fundamentals Chapter 5.
SYSTEM ADMINISTRATION Chapter 4 Network Media, Connectors, and Their Characteristics.
Lecture 8 Cable Certification & Testing:. Cable Distribution Cable Distribution Equipment UTP (Unshielded Twisted Pair) UTP Cable Termination Tools UTP.
Copper Media Describe the specifications and performances of different types of cable. Describe coaxial cable and its advantages and disadvantages over.
Five components of data communication
SIGNAMAX CABLING SYSTEM COMPONENTS. TRANSMISSION MEDIA Twisted Pair.
CABLING SYSTEM INSTALLATION. Installation Quality The quality of installation is the most serious problem in implementation of the telecommunications.
Networking and Health Information Exchange Unit 2b Network Media and Hardware Communication Devices Component 9/Unit 2b1 Health IT Workforce Curriculum.
SIGNAMAX CABLING SYSTEM COMPONENTS. TRANSMISSION MEDIA Twisted Pair.
Design and Documentation Chapter 8. Network Design Issues Your first step in the process is to gather information about the organization. This information.
CABLING SYSTEM INSTALLATION. Installation Quality The quality of installation is the most serious problem in implementation of the telecommunications.
+ Transmission Media. + Local Area Networks LANs consist of Transmission media and network nodes. Transmission media is a pathway that carries the information.
COPPER AND FIBER REVIEW
TELECOMMUNICATIONS SPACES. WORK AREA WA Work Area Work Area (WA) Telecommunications Outlet (TO) Horizontal subsystem cables Equipment and patch cords.
TELECOMMUNICATIONS SPACES
Transmission Media. Characteristics to consider for Media Selection Throughput Cost Installation Maintenance Obsolescence vs bleeding edge Support Life.
CABLING SYSTEM PROTECTION. Screening/Shielding  1 In the Signamax Cabling System for the efficient screening of the telecommunications systems, the screen.
LECTURE#6 - CABLES Asma AlOsaimi. Copper Coaxial Cable - Thick or Thin Unshielded Twisted Pair - CAT 3,4,5,5e&6 Optical Fiber Multimode Singlemode Wireless.
Physical Transmission Media Chapter 8. Objectives In this chapter, you will learn to: Identify the characteristics of wireline transmission Describe the.
LECTURE#6 - CABLES Asma AlOsaimi. Copper Coaxial Cable - Thick or Thin Unshielded Twisted Pair - CAT 3,4,5,5e&6 Optical Fiber Multimode Singlemode Wireless.
Fatima Alibrahim Intro. to Telecommunication MISY3312
Copper-Based System Residential Cabling Topologies & Standards 8
Level 2 Diploma Unit 10 Setting up an IT Network
Networking TRANSMISSION MEDIA.
Smitty’s Two Minute Drill Mixed Content -05
Conducted and Wireless Media (Part I)
Essentials of Networking
Horizontal and Back Bone Cabling
Transmission Media.
Presentation transcript:

Cabling system components EQUIPO 2 EQUIPO 2 Cabling system components EQUIPO 2

The cable

Horizontal Cables Horizontal cables run between a cross-connect panel in a wiring closet and a wall jack, are most often implemented with 100-ohm, four-pair, unshielded twisted-pair (UTP), solid-conductor cables, as specified in the ANSI/TIA/EIA-568 Standard for commercial buildings. The Standard also provides for horizontal cabling to be implemented: 62.5/125-micron or 50/125-micron multimode optical fiber 150-ohm shielded twisted-pair (STP) cable.(but does not recommend)

Backbone Can be implemented using 100-ohm UTP, 62.5/125-micron or 50/125- micron multimode optical fiber, or 8.3/125-micron single-mode optical cable. Neither 150-ohm STP nor coaxial cable is allowed. Optical fiber is the preferred installation medium because of distance limitations associated with copper wiring. a fiber backbone is that glass does not conduct electricity and is thus not subject to electromagnetic interference (EMI)

Modular Patch Cables Modular patch cables (patch cords) are used to provide the connection between field-terminated horizontal cables and network-connectivity devices and connections between the wall- plate jack and network devices. Patch cords are made with stranded conductors because they are more flexible. Problems with the patch cables: The first challenge lies within the modular plugs themselves. the untwisting and splitting of the pairs the mechanical crimping process that secures the plug to the cable

Pick the rigth cable You must know the installation environment and what the applicable NEC and local fire-code requirements will allow regarding the cables’ flame ratings. Your second decision on cabling must be on media type.. For fiber cable, you will need to specify single-mode or multimode, and if it is multimode, you will need to specify core diameter, i.e., 62.5/125 or 50/125. For UTP cables, you need to specify the appropriate transmission-performance category.

Cabling pathways

ANSI/TIA/EIA-569-A Commercial Building Telecommunications Pathways and Spaces Standard for concealing, protecting, and routing your cable plant. Must be electrically grounded per the ANSI/TIA/EIA-607 CommercialBuilding Grounding and Bonding Requirements for Telecommunications.

CONDUIT Conduit is pipe. It can be metallic or nonmetallic, rigid or flexible and it runs from a work area to a wiring closet. Only 40 percent full by your current cable needs. Conduit should only be filled to a maximum of 60 percent, so this margin leaves you with room for future growth.

Cable Trays Cable trays are typically wire racks specially designed to support the weight of a cable infrastructure. Cables simply lie within the tray, so they are very accessible when it comes to maintenance and troubleshooting.

Raceways Raceways are special types of conduits used for surface mounting horizontal cables are mounted on the outside of a wall in places where cable is not easily installed inside the wall.

Fiber-Protection Systems As with raceways, fiber-protection systems are special types of conduits and cable- management systems designed specifically to address the special protection needs of optical-fiber cable. Although maintaining is important for all cable media, cable will eventual signal loss, which translates to lost data, troubleshooting, downed network connections, and lost productivity.

Conectores y terminales fijas

Wiring Closets

TIA / EIA ANSI/TIA/EIA-568-B ANSI/TIA/EIA-569-A

Additional requirements There shall be a minimum of two dedicated 120V 20A nominal, nonswitched, AC duplex electrical-outlet receptacles, each on separate branch circuits. There shall be a minimum of one room per floor to house telecommunications equipment/ cable terminations and associated cross-connect cable and wire. Lighting shall be a minimum of 500 lx (50 footcandles) and mounted 2.6 m (8.5 feet) above the floor There shall be a minimum door size of 910 mm (36 inches) wide and 2,000 mm (80 inches) high without sill, hinged to open outward or slide side-to-side or be removable,

Wall-Mounted Brackets For small installations and areas where economy of space is a key consideration, wall-mounted brackets may provide the best solution. Wall-mounted racks such as MilesTek’s Swing Gate wall rack in Figure 5.9 have a frame that swings out 90 degrees to provide access to the rear panels and include wire guides to help with cable management.

Wall-Mounted Brackets wall-mount rack with cable management Skeletal Frames

Wall-Mounted Brackets Full Equipment Cabinets Shelves available for 19-inch racks

Electrical Grounding Electrical Grounding Cross-Connect Devices The 66 Punch-Down Blocks

Modular Patch Panels

Fiber-Optic Connector Panels A fiber-optic connector panel A consolidation point

Administration Standards NOTE. Network administrators should be judged by the neatness of their wiring closets.