Locking the Means of Egress in Health Care Facilities

Slides:



Advertisements
Similar presentations
NFPA-101, LIFE SAFETY CODE, 2003 EDITION Chapter 15 Existing Schools
Advertisements

Annual Fire Door Inspection
2009 Edition – NFPA 101 Steve Hornyak, DAHC, CDT, FDAI
MEANS OF EGRESS.
Safety in Hospitals A Computer – Based Learning Program for Students.
School Safety: The Fire Marshals Perspective. School Safety Traditionally focused on: Fires Weather Hazardous Materials Child protection The New Threats.
Electronic Locking and Exemption Request Form Training
Security, Fire Safety and Health and Safety at Central European University.
NFPA 72 and NFPA 101 Supervised Automatic Sprinkler System Overview
State Fire Marshal Question and Answer Session with the Louisiana Automatic Fire Alarm Association March 19, 1999.
DEPARTMENT OF DEVELOPMENT SERVICES BUILDING DIVISION Ronald L. Lynn, Director/Building Official Gregory J. Franklin, Assistant Director Neil Burning, Manager.
“Categorical CMS Waivers”
 Please mute your line to reduce background noise  Do not put us on hold if you have background music on your hold line.  At the end of the presentation.
Michigan Department of Licensing and Regulatory Affairs Bureau of Construction Codes.
Model 3000 Magnetic Lock 1500 lbs. Holding Force Fas-Trak Mounting System 12 or 24 VDC or VAC field selectable One Piece Housing Low Power Consumption.
Cancer Center Training 2012 Cancer Center Training 2012 “Defend in Place” Strategy for Fire Alarm Activations Cancer Center Building #7559.
Texas Department of Insurance State Fire Marshall’s Office Sixth Report on State University Fire Safety January 2002.
What’s On Your Wall? Introduction Department of Public Safety Division of Fire and Life Safety.
2014 TWIN STATE SEMINAR JULY 18, 2014 Impact of CMS’ Adoption of 2012 NFPA 101 & 99 Dave Dagenais, CHFM, CHSP, FASHE.
Fire Prevention and Safety Health Science Class. Rationale: Fires may occur at any time, as a result of overloading wiring, smoking, improper chemical.
Prevent False Alarms Eugene A. Cable, P.E., M.S.F.P.E. Life Safety Consultants NEHES Honorary Member 412 Horse Heaven Road Averill Park, New York
Retirement Home Regulated under the Retirement Home Act, 2010.
2012 International Fire Code Adopted as the minimum fire safety standard by the State of Wyoming City of Sheridan must adopt the minimum standard to retain.
Department of Fire Services- Division of Fire Safety Emergency Planning- Emergency Drills 527 CMR 10.
Presented by Gene Cable, PE, FPE Dave Dagenais, BS, SASHE, CHFM, CHSP Friday, March 19, 2010.
Health Facilities Planning Seminar Plan Review Division Irvin J. Poke, AIA, Chief Todd Y. Cordill, NCARB, Assistant Chief Providing for Michigan’s Safety.
Business Owners and Managers and the Fire Code
The Physical Environment Tracers How Should I Prepare for the Physical Environment Tracers? Healthcare Engineering Consultants  Will limit.
Building Codes and Interior Design
Toolbox talk on BS 5266 a guide to the maintenance of emergency lighting systems Yorkshire Electrical Services (Contracting) Limited.
Privacy and Security of Protected Health Information NorthPoint Health & Wellness Center 2011.
1 Canadian Fire Alarm Association The Perspective from a Municipal Building Department Wednesday May 5, 2010 Presented by:Mike Seiling, CET, CBCO, Chief.
© 2008 Delmar, Cengage Learning Property Security, Emergency Response, and Fire Protection Systems Chapter 13.
© 2015 American Society for Healthcare Engineering, a personal membership group of the American Hospital Association 155 N. Wacker Drive, Suite 400 | Chicago,
Fire Inspection and Code Enforcement, 7 th Edition Chapter 4 — Construction Types and Occupancy Classifications Inspector I.
MINNESOTA CHAPTER AUTOMATIC FIRE ALARM ASSOCIATION Requirements of the 2003 Minnesota State Fire Code relating to Group R Occupancies September 14, 2006.
Code Analysis: Don’t try this at home. Identify the relevant codes  Local building code  Local accessibility code (or ADA)  Local fire code (or the.
SLAC NATIONAL ACCELERATOR LABORATORY C ONTROLS D EPARTMENT S AFETY S YSTEMS S ECTION NFPA , Access Control Systems, and Emergency Egress at SLAC.
Courtesy: Jeff Anderson, RCDD Associate / Systems Project Manager Communications, Security & Technology Division October 14, 2015 Locking the Means of.
Maine State Fire Marshals Office1 Laws and Codes Relating to Existing Apartment occupancies in the State of Maine Mark Stevens CFI-II, CFPS, CFPE Inspections.
Codes.
OCCUPATIONAL SAFETY AND HEALTH Do you remember those school fire drills ? Well, here you go again !
Constructing for Health and Safety Permit Review Process for Senior Healthcare Facilities in Colorado May 15, 2014.
SIMPLE & MODULAR PC BASED DOOR ACCESS CONTROL v1.00
Physical and Technological Security
“Electromagnetic Locks, Electric Strikes
Carbon Monoxide Detection: Code and Legislation Updates
SAFETY | TRAINING | CONSULTANCY| STAFFING SOLUTIONS
Blue Access Technologies
CODE REVIEW: DOH Article 28 Compliance
Emergency Planning for Institutional Facilities
Campus Emergency Preparedness
CIHQ - All Rights Reserved 2017
THE IMPORTANCE OF DEVELOPING A FIRE STRATEGY FOR ANY PROJECT
ARCHITECTURAL SAFETY FEATURES –Exit Separations –Continuation of Exit Stairs from lower to upper floors –Discharge from Exits FIRE PROTECTION FEATURES.
Fire Door Inspections Qualified Training
Electrical Receptacle Testing
Life Safety Drawing Template
Texas Department of State Health Services
NFPA 101 Occupancy Specific Requirements
General Requirements of NFPA 101
Fire Prevention and Safety
Ambulatory Health Care vs. Business Occupancy
Nonpublic School Security Aid Program
RESTRAINT & SECLUSION(R/S) for NON-NURSING
Area of Refuge It’s the Law!
Cheryl Edwards, Fire Marshal
Emergency Preparedness Requirements
Code Development & Adoption
Restraints & Seclusion For Licensed Nurses
Presentation transcript:

Locking the Means of Egress in Health Care Facilities Jeff Anderson, RCDD Associate / Systems Project Manager Communications, Security & Technology Division October 14, 2015

What will I be talking about today Why would you lock the means of egress? When you lock what codes apply and who is involved? What are the special locking arrangements per NFPA 101, Chapter 7? What are clinical needs and special needs locking arrangements per NFPA 101, Chapter 18? Examples of acceptable locking arrangements

Why would you lock the means of egress? Pediatric Units Emergency Departments Behavioral Health Units Intensive Care Units Other Considerations

When you lock what codes apply and who is involved? Authority Having Jurisdiction Who is involved with the development of a locking strategy? NFPA 101 - Life Safety Code 2012 edition Florida Building Code – 2014 (fifth edition) FGI – Guidelines for Design and Construction of Health Care Facilities

What are the Special Locking Arrangements from NFPA 101 Chapter 7? Delayed Egress Where to use this lock? Some considerations Code requirements Access Control Does it restrict egress? Example of use Code Requirements

What are the Clinical Needs Locking Arrangements per NFPA 101 Chapter 18? 18.2.2.2.5.1* A18.2.2.2.5.1

Clinical Needs 18.2.2.2.5.1* Door-locking arrangements shall be permitted where the clinical needs of patients require specialized security measures or where patients pose a security threat, provided that staff can readily unlock doors at all times in accordance with 18.2.2.2.6. A.18.2.2.2.5.1 Psychiatric units, Alzheimer units, and dementia units are examples of areas with patients who might have clinical needs that justify door locking. Forensic units and detention units are examples of areas with patients who might pose a security threat. Where Alzheimer or dementia patients in nursing homes are not housed in specialized units, the provision of 18.2.2.2.5.1 should not apply. Criteria to be met for code compliance How would this locking arrangement look?

What are the Special Needs Locking Arrangements per NFPA 101 Chapter 18? 18.2.2.2.5.2* A18.2.2.2.5.2

Special Needs 18.2.2.2.5.2* Door-locking arrangements shall be permitted where patient special needs require specialized protective measures for their safety, provided that all of the following criteria are met: items 1-5a and b. A18.2.2.2.5.2 Pediatric units, maternity units, and emergency departments are examples of areas where patients might have special needs that justify door locking. Criteria to be met for code compliance How would this locking arrangement look?

Examples of Acceptable Practice Pediatric Unit Stair Door Magnetic lock was used to lock the door Mechanical latch, non-locking was used to maintain the required fire safety Card readers on both sides of the doors, for staff entry and exit Audio/Video intercom door stations on the both sides of the door Audio/Video intercom master station, remote release and emergency break lock power button at the attending nurse station Re-entry required by Code Secure Unsecure

Examples of Acceptable Practice Service Elevator Lobby The doors on the left Magnetic locks were used to lock the doors Electric latches, non-locking and in the retracted position, release on general building fire alarm to maintain the required fire safety Card readers on both sides of the doors, for staff entry and exit and activation of the auto operators Secure Unsecure Secure

Examples of Acceptable Practice Service Elevator Lobby The doors on the right Delayed magnetic locks for locking the doors and the means of egress from the elevator lobby Electric latches, non-locking and in the retracted position, release on general building fire alarm to maintain the required fire safety Card readers on both sides of the doors, for staff entry and exit and activation of the auto operators Remote annunciation at the attending nurse station of the activation of the delayed egress function Secure Unsecure Secure

Examples of Acceptable Practice Pediatric Unit Entrance and Exit Pediatric Unit Stair Door Magnetic locks were used to lock the door Mechanical latch, non-locking were used to maintain the required fire safety Card readers on both sides of the doors, for staff entry and exit, not required by code Audio/Video intercom door stations on the egress side of the door for communication to the attending nurse station Audio/Video intercom master station, remote release and emergency break lock power button at the attending nurse station Unsecure Secure

Examples of Acceptable Practice Public Stair Door Magnetic lock was used to lock the door Mechanical latch, non-locking was used to maintain the required fire safety Card reader on the stair side of the door, for staff entry and exit, not required by code Audio/Video intercom door stations on the egress side of the door for communication to the attending nurse station Audio/Video intercom master station, remote release and emergency break lock power button at the attending nurse station Secure Unsecure

Examples of Acceptable Practice Access Control and Special Needs Application Magnetic locks were used to lock the door Mechanical latches were not required, because these were not cross corridor doors or compartment doors Card reader on one side of the doors, for staff entry and exit, not required by code A motion sensor and request to exit button on the secure side of the door for free egress, access control application Audio/Video intercom door station on the egress side of the door for communication to the attending nurse station Audio/Video intercom master station, remote release and emergency break lock power button at the attending nurse station for the special needs application Secure Unsecure

What I covered today Some reasons why you would lock the means of egress The codes that apply and who is involved Identified and explained the special locking arrangements per NFPA 101, Chapter 7? Identified and explained clinical needs and special needs locking arrangements per NFPA 101, Chapter 18? Explained some examples of acceptable locking arrangements