Paradigm Change – New Approaches in Filtration & Pre-Filtration Improves Sustainability and Profitability Jim Phene Business Development Director.

Slides:



Advertisements
Similar presentations
TORO ID PRE COOLER (Patent Pending) for Air Cooled Condensers Improving Cooling Efficiency and Energy Conservation in Air Cooled HVAC Systems.
Advertisements

High performance; from 1 metric ton to 100 metric tons instant purification facility per hour, 2400tons per day Low energy consumption (25 kw/h – 38 kw/h)
IMO 107(49)/46 CFR ppm Bilge Separators 15 ppm Bilge Alarms
Subterranean Success: Geothermal Energy Powering Schools
Find the perimeter. Areas Grade 7 - CIC 15-Feb-14 Area of a Rectangle X = X = X = BAh B B h h B h B = base h = height Must learn formula.
< C ² Carbon Reduction Technology Ltd A Revolution in Lighting - The e-lamp.
1 1  1 =.
1  1 =.
HVAC Basics Bin Yan HVAC – Heating, Ventilation, Air-conditioning.
I n t e g r i t y - S e r v i c e - E x c e l l e n c e Headquarters U.S.A.F. 1 Commodity Councils 101 NAME (S) SAF/AQCDATE.
Factoring Quadratics — ax² + bx + c Topic
CM 4120 Julie King Original Presentation by Todd King and I edited it.
Dairy Surface Water Disinfection - Case Study -. Dairy Farm - Continental, OH 600 head of dairy cattle Milked 3 times/day Facility Background.
Gene Swetin 11/01/2002 Mechanical Engineering Group Accelerator Systems Division Cooling Water Supply for Beamline Components.
Harnessing the energy of the sun to provide safe drinking water for the world.
Introduction to Cost Behavior and Cost-Volume Relationships
Innovative Design for Efficient and Reliable Filtration Systems.
Advantages of Filtration in Printing Reduce down time Reduce waste Reduce maintenance Environmental benefits.
Can a Heat pump replace a boiler? Not without a bit of thought. Maximum efficiencies are unlikely to be achieved without a few changes to the system (Press.
WATER CONSERVATION ISO
Energy Efficient Steam Systems
Unit Operations in Chemical Industries BY Dr.LEK WANTHA
BBA Part1_1 (Gajaseni, 2001)1 Man and Environment Asst. Dr. Nantana Gajaseni.
Program Overview February 25, Program Summary Approximately $14M in incentives per year Cap for Large Customers: $300,000 per year Prescriptive.
1 POLYGENERATION OF ELECTRICITY, HEAT and ULTRA PURE WATER for SEMICONDUCTOR INDUSTRY Chuanfeng Liu Supervisors: Andrew Martin EGI KTH Aapo Sääsk Xzero.
NANOSOLUTION FOR GAS TURBINES CARTRIDGE FILTER. CURRENT TECHNOLOGY.
The Concept of the Basic Liquid
Workforce Opportunity Services An Overview 1 Dr Art Langer.
Lindbergh Field International Airport New Terminal Bill Mahoney LSW Engineers.
Ottawa Microturbine Application Workshop jan Return of Experience for Microturbines Running on Landfill Gas // waste water gas in Europe
Energy Savings Impacts of the Advanced Energy Design Guide: Small Office Buildings Bing Liu, P.E. Research Engineer Pacific Northwest National Laboratory.
HF Series Compressed Air Filters Flows from 20 to 21,250 scfm (34 to m 3 /h) Maximum working conditions of 300 psig & 150°F (21 bar, 66°C)
Facebook Pages 101: Your Organization’s Foothold on the Social Web A Volunteer Leader Webinar Sponsored by CACO December 1, 2010 Andrew Gossen, Senior.
The BallTech ® System Energy saving opportunity for water-cooled chillers.
Corrosion Products Sampler (CPS)
1.1.1 Concept and characteristics of a system A system is a collection of well-organised and well-integrated elements with perceptible attributes which.
Number bonds to 10,
Water Resource Efficiency Gerard Enright STEM Project.
ADVANTAGES Water savings Crop response Labour savings Fertilizer savings Less weed growth Drip Irrigation System Layout & Design.
Chapter 4 FUGACITY.
Airflow and BSC Biosafety and Biosecurity Awareness Training
ERG (Air Pollution Control) Ltd Two Technical Advances in Wet Chemical Scrubbing Technology Richard Hanson MA MEng CEng MIChemE ERG (Air Pollution Control)
Whirlwind cleaning power to clean your cooling tower.
Antunes Water Filtration Technologies Introduces to You:
ETL Multi Media Grey Water Filters and Pre Reverse Osmosis Filtration.
Design and Construction of an Induction Furnace (Cooling System)
Plant Utility System (TKK-2210) 14/15 Semester 4 Instructor: Rama Oktavian Office Hr.: M-F
Matter.
Automatic Tube Cleaning System for Condensers and Heath Exchangers
Types of Positive Barrier Screens  Rotary Drum  Fixed Vertical Plate  Vertical Traveling – belt and panel  Non-Vertical Fixed Plate  Horizontal Fixed.
2 nd Integrated Seminar COOLING SYSTEM2 INTRODUCTION TYPES OF COOLING SYSTEMS  ONCE THROUGH COOLING  SPRAY PONDS  SPRAY TOWERS 
California Emerging Technologies Statewide Program Dynamic Air Quality Solutions December 10, 2012.
Filtration. Why filter? Emitter Plugging Emitter Wear.
We can…. 2 GLOBAL REFERENCES Rev: 00 References :
Variable Speed Applied to Pumps. Life Cycle Costs - Courtesy of Hydraulic Institute and Europump Initial cost is not the only cost associated with a pump.
SSi Characteristics of modern, energy efficient hydraulic systems Small reservoir volume (relative to flow rate) Most fluid in the system is in constant.
ELECTRI-CITY: Energy Management for the Modern U.S. City.
By: Jim Kibby Fouling and ROI Tools (Return On Investment)
Presentation Title Presented by Joe Blow Industrial Filtration Solutions for 2015.
Presentation Title Presented by Joe Blow Top Applications.
Presentation Title Presented by Joe Blow Selling Strategies Hector Vigil Steve Geisel.
Presentation Title Presented by Joe Blow Process Cooling LAKOS JCX and PRX Systems Hector Vigil Steve Geisel.
Overview of HVAC Filtration
Presentation Title Presented by Joe Blow Heat Transfer 101 & ROI.
GPAEE New Technologies Blitz 960 Brook Road, Unit 3, Conshohocken, PA * Phone: (610) * Fax: (610) * Feb 18, 2016.
The below slides were presented by Randy Delenikos of LAKOS at World Ag Expo 2017 on Feb 16, 2017 The seminar was hosted by the International Center for.
Steam / condensate system Condenser
One World Filter.
· Infill not washed bi-annually owners will contradict government
Presentation transcript:

Paradigm Change – New Approaches in Filtration & Pre-Filtration Improves Sustainability and Profitability Jim Phene Business Development Director

40 Years of LAKOS

Pair of Dimes - Paradigm

Paradigm – Frame of Reference

Frame of Reference – Self-Imposed Limits

Open Mind The Mind is like a parachute…it only works when it is open!

Presentation Take-Aways Sustainability Reliability Best Interest of the End User

Entropy The tendency of a system to move from order to disorder….

Entropy in Action The tendency of a system to move from order to disorder….

Barrier Filtration Barrier Filtration - Screens

Issues with Barrier Filters – Bags & Screens Bag/Screen Failures Misleading Flow Rate Variation Change Frequently Filtration not available during change out

Issues with Sand Media – Cooling Water Applications Significant Water Loss Loss of Filtration During Back Flush Infiltration of Media Surface Sealing Maintenance Space in large applications

LAKOS Separator

No moving parts to wear out No screen or filter element to plug/fill No maintenance required (backwashing+) No water loss Low / steady pressure loss Continuous / uninterrupted operation LAKOS Separator Benefits Centrifugal Filtration – Separators

Separator Demo Separator

Typical Applications Full Stream or Inline of Full Flow Side Stream or % of Full Flow Basin or Sump Sweeping Inlet Water Pre-Filtration

Technique: Full Stream

Typical Applications – Full Stream

Typical Applications – Pre-Filtration

Typical Applications – Heat Exchanger

Inlet Water Filtration - Seawater

KORI Nuclear Power Corporation- K1 & K2-KOREA

Technique: Side Stream

90% of.35, 1, 5, & 10 Micron

Technique: Basin Cleaning

Basin Sweeping

Entropy in Action The tendency of a system to move from order to disorder….

Real World Economics AB Ton Cooling Tower Retrofit with Basin Cleaning

INDEPENDENT TEST RESULTS

Real World Economics AB Ton Cooling Tower Retrofit with Basin Cleaning

ROI and Rule of 72 Saved: $46,481 LAKOS Cost: $75,000 Payback: ($75,000/$46,481) X 12 Months equals months months/(12 months/year) = 1.61 years (72/1.61) * 100 = % ROI

Value of Filtration Energy savings: 8-10% Maintenance savings: 60-90% Water savings: 5-10% Chemical savings: 5-15% Maintain Efficiency Extend Component Life Improve Productivity

Presentation Take-Aways Sustainability Reliability Best Interest of the End User

Questions?