Your Solution for: Energy Smart Management Real Time Power Monitoring Fuel Theft Prevention Technical presentation.

Slides:



Advertisements
Similar presentations
eGenKit Remote Monitoring Solution
Advertisements

What we do Larotecs Web2M is an off-the shelf, end-to-end, web-based solution designed to manage multiple widely distributed devices.
OfficeTrack Fleet Management Solution. OfficeTrack OfficeTrack Fleet Management Solution allows business and companies to view the location of their fleet.
G-Eye Extending your monitoring & control capabilities
Model H Free Standing Static Transfer Switch. Why choose a model H static transfer switch? Increases power availability. True solid state. Rugged, reliable.
Model W Wall Mount Static Transfer Switch. Why choose a model W static transfer switch? Increases power availability. Integrated maintenance bypass. True.
EMS ROMC Environment monitoring system for ROMC..
VSE Corporation Proprietary Information
Poseidon 4002 Rack monitoring 1. Poseidon: Monitor & Control 2.
Lineage Power - Total Efficiency TM Smart Grid A Telecom / Commercial consumer’s perspective Paul Smith – Technical Marketing Manager, Lineage Power
June 2010 At A Glance The Room Alert Adapter software in conjunction with AVTECH Room Alert™ devices assists in monitoring computer room environments as.
Remote Monitoring and Management Solutions ®
 Wireless, Web-Based Monitoring System  Alarm/Event Notifications by Text Message and or  VPN Connection for Fast Response to Alarms and Events.
PM-RS / March Industrial CMC. PM-RS / March Industrial CMC III Where did it start? Where is it headed? Rittal supplies infrastructure for.
All content in this presentation is protected – © 2008 American Power Conversion Corporation Symmetra ® LX – redundant UPS High performance, redundant.
SCADA and Telemetry Presented By:.
G4 Control and Management Solution for Data- Centers and Computer Rooms.
GML-3 GPRS BASED METER AND LOGGER THREE PHASE METER WITH INBUILT DATA LOGGER © Embuilt Technologies Visit us at Or For.
NetVuze Precision Network Meter standalone, easy to use, networked with data logging.
Authorized Dealer.
Module 10: Monitoring ISA Server Overview Monitoring Overview Configuring Alerts Configuring Session Monitoring Configuring Logging Configuring.
1 Weblite Product Introduction. 2 Control Equipment via the Internet 8 Universal Inputs 8 Universal Outputs software selectable as analog or digital signals.
Welcome to OmniMetrix. Who We Are OmniMetrix ® is the leader and pioneer in machine to machine (M2M) wireless remote monitoring, control and diagnostics.
SmartMQn Motor Horner APG, LLC September 9, 2008.
New Product Developments World Leaders in Combustion Management Solutions New Products New Products.
Alarm units AL 175 NT and Aeon Gold For small, medium and large power range.
Aeon Gold – System Overview *TCP/IP *SNMP Aeon Gold Display Unit *Advanced setup and *monitoring through *WinPower *SW Download PC w /WinPower Aeon 4000.
U-PROX SMART HANDLE Fully incorporated Wireless Handle and Furniture Locking Set.
Artificial Intelligence In Power System Author Doshi Pratik H.Darakh Bharat P.
SIMPLE & MODULAR PC BASED DOOR ACCESS CONTROL v1.00
Davis Industries Group
Hydromet Cloud Presentation
Poseidon 4002 Rack monitoring.
SCADA For DG Sets Management for TMTL
Hydromet Cloud Presentation
ICON Signals Event Alert Notification Platform Overview March 28, 2017
IP-based 8-port Switched Power Manager
Maintain, Manage And Monitor Outdoor Systems Remotely
1+1 Ethernet Failover & Network Protection Switches
What is it ? …all via a single, proven Platform-as-a-Service.
Training on Power Monitoring and Management Solution
Eric / Echelon GCA 17th October, 2010
Information Technology Deanship
DS3 Fail-over Protection Switch
2N® Access Unit Touch Keypad
How SCADA Systems Work?.
CHAPTER OVERVIEW SECTION 5.1 – MIS INFRASTRUCTURE
WISENET Wireless Sensor Network
The Internet of Things (IoT)
IP-AK2 Access Control Solution
ICP DAS Power Monitor and Management Solution 2016,03,28
PowerValue 11/31 T Sales Presentation
2N® Access Unit Touch Keypad
+Vonus: An Intuitive, Cloud-Based Point-of-Sale Solution That’s Powered by Microsoft Office 365 with Tools to Increase Sales Using Social Media OFFICE.
Sunnytek sensor networks
Smart battery management
Wavestore Integrates… Paxton Net2 Access Control
Hydromet Cloud Presentation
Why MastMinder? Customised solutions: Experience:
Control & Management Solutions
2N Access Unit 2.0 Multi-technology access control readers.
Total HVAC Control from anywhere Easy control that can save a fortune
Integrated gateway-server
PowerLogic™ offer for the basic metering market
NFMT Quick Fire Presentation: Solving Your Peace of Mind Problem Presenter: Cam Rogers Director of International & Western US Sales June 12, 2019.
GasGard 100 Control System
Network Monitoring System
Power monitoring software
Presentation transcript:

Your Solution for: Energy Smart Management Real Time Power Monitoring Fuel Theft Prevention Technical presentation

How it Works: Site Controller Unit Real Time Software Stand alone intelligent unit deployed at each site GPRS, LAN or Private APN or VPN or Internet or Satellite Real Time Software Web-based software platform to gather data from site controllers, control site’s equipment, analyze and produce reports…

Site Controller Unit Real time data collection Remote control of local operations Safe access to authorised users only On board storage Communication Protocols SNMP RS232 RS485 1-wire GPRS Ethernet 4-20mA Voltage Current Temperature Humidity Fuel level x 2 Dry contact in Relay outputs Etc ...

Fuel Sensor Easily installed hydrostatic pressure sensor Configure to any size or shape tank Accuracy of +/- 0.25% full scale Various depth ranges Tamper alarm if disconnected

Generator communication RS232 available to certain generator control panels RS485 available to certain generator control panels Dry contact inputs available for Alarm inputs Typically – Generator running Generator on load Common alarm ... etc Relay output contacts available for control Test start generator Reset fault condition Force AUTO mode Reset maintenance alarm

Generator communication options To monitor generator running Via RS232 or RS485 or Generator control panel dry contact output Via MastMinder Generator Interface Unit to measure voltage on phase To monitor generator on load Via auxiliary dry contacts on Automatic Transfer Switch To monitor generator Common Alarm To control generator Via RS232 or RS485 or MastMinder relay output contacts

Typical wiring diagram Power supply 12 to 48 volts Backup battery option One or two fuel tanks One or two generators Water in fuel sensor Generator running sensor Generator on load sensor Relay to control gen start Relay to control fault reset Relay to control force AUTO Relay to control maint alarm Further inputs available for – AC Voltage sensors AC Current sensors DC Voltage sensors DC Current sensors Temperature sensors Humidity sensors etc ...

Site communications to server GPRS Ethernet SMS Satellite

The results What you will see on the next few slides is the results of the data collection

Convenience of the Smartphone Real Time Monitoring wherever you are Immediate Actions via Remote Control Safe Access to authorised users only

More features of the Smartphone Receive continuous updates or only alerts Test start generators, reset faults remotely Access location data

Overview at the Operations Centre Red for Critical, Blue on Grid, Green on Generator Yellow on Battery, ! For Fault and “Low Fuel”

Detail at the Operations Centre View site values like site battery volts, phase volts, etc. View site values like fuel levels, temperatures, etc.

More details at the NOC View site events like when did generator start / stop View site events like generator faults, MCB trip, etc.

Automatic and manual reporting Regular reporting automatically produced and emailed Reports may also be produced for any time frame / site Reports may be auto emailed to any number of recipients Reports may also be produced on triggered events

View graphs by selecting manually or by automatic reporting Graphs may easily be produced manually or automatically Reports may be produced in PDF or Word or Excel format If the data is available we will configure any report for you

Auto Alerts via SMS and Email Auto Alerts may be configured for any number of users May be received by SMS and Email and Android App

Simple and secure configuration Only an Administrator can add users to the system Only an Administrator can authorise users functionality Restrictions include who can see which sites and also who can perform activities such as test starting a generator or remotely resetting a fault condition

Key Benefits Opex Decrease Energy Efficiency Reduced service costs and in person maintenance on remote sites Control fuel theft and “short deliveries” Generator running times may be greatly reduced when Hybrid Power Management function is enabled Energy Efficiency Programmable preferred power sources for automatic sequences Identification of power «waste» in the network Benchmarking of site performance Monitor the performance of your solar sites Use the system to automatically control and exercise the backup generator at solar sites

Key Benefits Longer Equipment Lifespan 100% Customizable and Scalable Improved Preventive and Corrective maintenance Better Battery Management Optimized voltage and temperature control Peace of mind knowing exactly what is happening at your sites 100% Customizable and Scalable Language and preferences can be chosen by client Customised technical and financial reports easily generated using the built-in Microsoft SQL Server Reporting Services System is licenced for any number of sites System is licenced for any number of users Numerous options and functionalities can be added over time

Total monitoring of your Passive Infrastructure Examples of Parameters Monitored Notification of fuel loss/ fuel fill-up/ water content in the tanks Notification of Generator Failed to Start on Mains Failure Generator common alarm faults on AMF panel (ability for remote reset) Generator start / stop times and running hours Commercial Grid on load / off load Battery voltage and levels of charge/discharge Rectifiers (any data can be extracted via our SNMP interface) Environmental and temperature alerts Shelter door open/ closed Access control and other security features (optional) Ability to monitor just about any voltage, current, temperature, humidity, level. And much more…

Applications Telecom Operator Networks ISPs Data Centers Power companies Solar sites Any Industry needing Continuous Power Supply

For further information, please contact us: enquiry@mastminder.com +44.17.87.26.90.18 Thank you, we look forward to hearing from you !