Epuni Primary School LED Lighting Trial 2016 Final Report

Slides:



Advertisements
Similar presentations
Gorokan Public School Energy Saving Plan Put your school logo here March 2010 These Stage 3 students conducted an energy use audit.
Advertisements

Welcome to EUROLUM GmbH Product Information Eurolum GmbH | Kirschallee. 90 | Potsdam | Tel. +49 (0) 331/ | Fax. +49 (0) 331/
Lighting the Way Efficiently
Carbon management plan WM Energy Managers' Forum, Friday 7th December 2012 Balbir Bassi Rugby Borough Council
Portable Classroom Controls Project Chuck Collins RCM Meeting April 27, 2007.
SOLVING ENERGY EFFICIENCY FINANCE IN THE PUBLIC SECTOR 100% INTEREST FREE ENERGY EFFICIENCY LOANS Interest Free Financing of Public.
CERT UPDATE TO GUILFORD COUNTY ENERGY AUDITS OF BELLE MEADE BUILDING BB&T BUILDING HIGH POINT COURTHOUSE & DETENTION CENTER HIGH POINT PUBLIC HEALTH BUILDING.
Management and Organisation of Electricity Use Energy Efficient Lighting Techniques Belgrade November 2003.
Harwood Union High School Board of Directors Presenters: Gabriela Meade and Lorne Nix Presented: April 25 th, 2007 Vermont Energy Education Program.
North American Operations Kalamazoo Plant Welcome to Kalamazoo.
Transformer De-Energizing & Dairy Plate Heat Exchanger Standard Protocol Proposal Presentation to the RTF February 20, 2013.
LED Lighting Lighting the way to the future. Background Information  Light Emitting Diodes (LED) have been around for more than 40 years.  Efficiencies.
SCSU Light Pole LED Retrofit Analysis Don Granlund III Krystal Sweeter Joseph A. Sanders.
Low Carbon Action Group results. The nature of our business means a large amount of energy needs to be used, but we are looking to compensate that with.
Grocery Measure: LEDs for Reach-In Display Cases Regional Technical Forum July 21 st, 2015 Mohit Singh-Chhabra.
Independent Lighting Solutions Specialist Case Study Packaging Store Developments in Professional LED Lighting.
Budget Update November 7, DISCUSSION ITEMS:
© 2005 by West Pharmaceutical Services, Lionville, PA. All rights reserved. This material is protected by copyright. No part of it may be reproduced, stored.
Who Says Energy Efficiency Can’t be Sexy? About Us Energy + Environment  Since 1999  Decades of experience in energy efficiency  We create jobs, lower.
Pg. 1 Energy Intelligence Program Monitor your industrial facility and save energy! Tool that provides real-time feedback to help you manage energy in.
Capacity Impacts of Energy Efficiency What We Know and What We Don’t Know March 11, 2014.
Foothill College & Space Science Center Bill Kelly Viron Energy Services (510) ext 13,
CT108 – Energy Audit Assignment. Top Down And Bottom Up Approach The Top Down Approach The “top down” approach assesses the total energy inputs which.
Day 10 Environmental Systems I Daylight as a primary lighting source Artificial lighting as a secondary source Room 102 Architecture Building.
The EnergyMizer Power Reduction & Conditioning System ®
10 Turn off Lights Not in Use Motion Sensors simple ways to go green
Management and Organisation of Electricity Use Electrical System Optimisation Belgrade November 2003.
Why do an Energy Audit? Environmental Impacts Most of the energy used in schools comes from electricity and gas. In 2004 this resulted in the production.
[DATE] [PLACEHOLDER FOR DISTRIBUTOR LOGO]. Low Wattage T8s: A Win for Customers Cost Savings Product Quality Easy Installation Energy Savings.
Why should we save energy? Americans now spend over $700 billion on energy Americans now spend over $700 billion on energy Energy demand is expected to.
1 Oconomowoc Area School District Energy Update 6-Month Status Report December 2005 – May 2006.
SPARTA | Fall 2014 LED Retrofit Capabilities at MSU (Revisited)
Phil Munsey, Facilities Energy Engineer Plant 17 Lighting Energy Reduction Project.
Energy Project M&V: Reports that Add Value October 27, 2015.
Calculating Energy Use and Converting Units Chapter 2.
Budget solutions Brittany K. David G. Alex D. Jeremy E. Austin A. Kristina C. Joe K. Brett H. Brittany K. David G. Alex D. Jeremy E. Austin A. Kristina.
Topic 7: Measuring Electric Power. Getting electricity to your home Power generating station  transmission lines  home Step- up transformer Step- down.
Lighting Efficiency. Lighting Efficiency Problem Suppose that 25 incandescent light bulbs rated at 100 Watt are replaced by 25 fluorescent lamps rated.
Lack of dedicated building meter – Solution: Estimate square footage of Herberger in relation to total area serviced by meter – Estimate 12% of total.
Lighting facts.  Lighting can be a big energy consumer in offices and production areas and experience shows that energy savings may be achieved - often.
LOGO Benefits of LED flood lightsLED flood lights.
2 nd PHASE DECEMBER 2010 –APRIL 2011 MEASUREMENTS & RESULTS.
Worcester Regional Transit Authority Key Performance Indicators Electric Bus Deployment Project December 17, 2015.
Combination Artificial & Daylighting
Presentation to the UUCF Coordinating Team October 5, 2016
Power Factor Correction The Definitive power solution
Union Church Path to Net Zero Energy (10 Years of Progress)
Fort Stanwix National Monument Energy Audit Contract
Operating Room HVAC Waste Reduction Jason Lang, MD, Seema Gandhi, MD University of California San Francisco Carbon Neutrality Initiative Fellowship Introduction.
Less power consumption than running a light bulb.
WDMA Technical Conference Chicago, IL 28 June 2016
2013/2014 Energy Report January 5, 2015
Hyde Park Central School District
CAPE & OUR PPN HISTORY IN BUSINESS SINCE 1953, PPN MEMBER SINCE 2014
Energy Incentive Programs
Energy Saving Guide How much in Energy Savings are you missing out on?
Economics of Energy Efficient Lighting
Iron Forge Educational Center: U. S
Energy, Energy Measurement and Calculations
SNC1D PHYSICS THE CHARACTERISTICS OF ELECTRICITY
Client Name Energy & Water Assessment August 27, 2014
Energy Saving Guide How much in Energy Savings are you missing out on?
Power.
Cathedral of the Immaculate Conception
Cathedral of the Immaculate Conception
Alabama Industrial Assessment Center
Island Energy Advisory Committee Board
[PLACEHOLDER FOR DISTRIBUTOR LOGO]
Economy Updates on EE&C Policies & Programmes
Cost of Electricity & Energy Usage Energy Use Recall: Measured in Watts (W) Electrical power is the rate at which electrical energy is produced.
Presentation transcript:

Epuni Primary School LED Lighting Trial 2016 Final Report

In late 2015, the Dynamis Project, assisted by the Ministry of Education, converted Epuni Primary School, in Lower Hutt, to LED lighting. Astara Technologies installed data loggers into the school’s main and sub power distribution boards to measure the power usage of the power and lighting circuits to compare the before and after effect of the LED lighting upgrade. Tristram Jay Electrical changed all the lamps and tubes in the school over to LED on these dates: 14th November exterior floodlights 15th November School Hall 21st November Main School block The lighting and power use was measured for one month before the changeover and the sub circuit loggers were removed 23rd December 2015 The lighting draw showed an average reduction of 81% The main building logger remained and power use for this building was logged for a full year. This logger was removed on 10th October 2016

Power Profile Loggers Fitted to the main distribution board supply inputs (3 phase into the main school and 2 phase into the hall). Fitted to the lighting circuits identified by the electrician. Logs at 10 second intervals to storage. Data is collected from the main supply phases and the lighting circuits. 5 loggers fitted, three of which are multi channel (6, 5 and 3 channels), and two single channel.

Logger Locations

This data shows that approximately half of the school’s total power consumption, before conversion, was for lighting. Date Total kWh Lighting kWh 5th Oct 15 36.69 18.39 6th Oct 15 69.99 38.6 7th Oct 15 65.12 34.24 8th Oct 15 67.29 33.44 9th Oct 15 67.19 36.14 10th Oct 15 57.22 22.3 11th Oct 15 64.97 33.85 12th Oct 15 95.73 53.72 13th Oct 15 113.82 58.852 14th Oct 15 109.09 46.22 15th Oct 15 66.01 26.009 Total 813.12 401.761

School Hall – total kWh by day (example period)

Example of detail: kWh by hour – main building

Main School Building - lights/other share Scale is kWh LED lighting change over began

Epuni School Main building - day/night lighting (12 months) Change over to LED lighting

Main Building lights only Before and after comparison week on week 2nd to 6th Nov. 2015 Scale is kWh Weekend Days 23rd to 27th Nov. 2015

Main building - before and after lighting conversion and repair work - 12th Oct - 11th Nov 2015 23rd Nov - 23rd Dec 2015 difference (kWh) percentage change Total kWh 2,385 1,685 -700 -29.35% Lighting kWh 990 183 -807 -81.52% Note 1: this comparison gives an indication of the scope of reduction possible. Note 2: The school Hall is not included as the variability of use would skew results.

Main Building - Lighting split day/night Scale is kWh LED lighting changeover began

“Night” in the examples is hours between 5 pm and 8 am. “Day” in the examples is hours between 8am and 5 pm. Day/Night Definition

Hall - Lighting kWh, showing day/night split LED Update weekend Scale is kWh

BACKGROUND As part of the Dynamis Project, Epuni Primary School was chosen because it is a small, low decile school, with a very strong community and environmental bias. The goal was to assess and document the effectiveness of using LED technology, to reduce the school’s power bills and their environmental footprint.   280 lamps in total, supplied by Ecopoint, were changed by an experienced electrician. This included not only the fluorescent tube lighting in the classrooms, but also the office, toilets, changing rooms, hall and flood lighting outside.  

COSTS and SAVINGS The total cost of this project was $14,100 plus GST. As this was a trial, Ecopoint supplied the lamps and replacement fittings at cost. The electrician only charged for two of the three days work and the data loggers to measure the power savings were provided at cost. It is estimated, that a small school would need to allow $18,000 to convert their school to LEDs. They would also need to assign a project manager for the job. As part of the Dynamis Project I provided my time and expenses for free; (approximately $3,000) Epuni Primary School's power bill for the previous year – 2015, was $4,714.00 – half of that was lighting ($2,357.00). In 2016, Epuni’s power bill totalled $1,645.55. So in their first year, they saved $1,645.55 LED lamps last for between 30,000 and 50,000 hours each. If they were running 9 hours day, 5 days week for 40 weeks a year, replacement would be needed between 16 and 27 years.

 LED LIGHTING In all cases, the LED lamps were brighter than the lamps they replaced - often many times brighter. In a couple of examples the Lux (lighting) levels went from 38 lux before conversion to 518 lux afterwards and 287 lux to 762 lux. Power usage was logged for one month before and one month after the conversion. The results were amazing - an average of 81% reduction in lighting power use! Their overall power consumption dropped by more than 30% during the last twelve months.   This showed that true power savings were higher than manufacturers specifications, as the componentry on older fluorescent units heat up and draw a lot more power than is needed for efficient operation. Infrared photographs taken at the school showed standard lamps running at over 100 degrees Celsius and the replaced LED lamp running at half that temperature. This reduced the maintenance costs throughout the school. Changing exterior floodlights to LED units with movement sensors also made a considerable difference.

Burnt out fluorescent fitting Highest temperature of an existing fluorescent fitting (left) and replacement LED fitting. (Infrared photos courtesy Tristram Buttner.)

Here is an example of the number of LED lamps fitted to a small school and the wattage reduction achieved with LEDs:   97 x 5ft fluoro tubes 65 watts reduced to 22 watts. 66% reduction 95 x 4ft fluoro tubes 58 watts reduced to 18 watts. 68% reduction 28 x circular ceiling lights 75 watts reduced to 18 watts. 76% reduction 31 x bayonet lamps fit 75 watts reduced to 12 watts. 84% reduction 17 x edison screw lamps 75 watts reduced to 12 watts. 84% reduction 7 x 400 watt exterior flood lamps reduced to 77 watts. 81% reduction 3 x edison screw 100 watts reduced to 9 watts. 91% reduction 2 x PAR 30 outside lights reduced to 30 watts. 60% reduction 3 x GU10 interior spotlights 50 watts reduced to 6 watts. 88% reduction 3 x edison R80 outside lights 80 watts reduced to 9 watts. 89% reduction

  Floodlights consume a disproportionate amount of power and in some schools, run all night. On the left is a typical floodlight before replacement, - this unit burns through 400 watts of power every hour. The replacement 120 watt LED unit on the right is brighter, gives a more even spread of light and uses a fraction of the power, as it is only activated when movement is detected.

Conclusion and Recommendations: Epuni Primary School is typical of many schools in New Zealand. Most schools face the same problems with inefficient and power-hungry lighting. Both fluorescent lighting in the classrooms and the outside floodlights need to be replaced, not only to save power but to reduce the likelihood of fittings over-heating. The Ministry’s policy states, if schools can be more energy efficient, the savings they make from their operating fund can then be used in other areas. It is my recommendation that this report be made freely available to all schools in New Zealand, so that they can make their own informed decisions on the costs and benefits available. Mike Rathbone, Project Manager, Dynamis Project.