Engineering Presentation

Slides:



Advertisements
Similar presentations
Packaged HVAC Equipment
Advertisements

Chapter 3. HVAC Delivery Systems
Trane Voyager™ rooftop units
Setup/Installation/Operation of an Environmental Control Unit (ECU)
Commercial Mechanical Requirements
100% Outside Air and Dehumidification Management
HVAC 101 The Basics of Heating, Ventilation and Air Conditioning
Foundations of Real Estate Management TM BOMA International ® Module 3: Building Operations I Heating, Ventilating, and Cooling the Building.
Engineered Products Make-Up Air for Heating and Cooling.
Components of HVAC System
HVAC Heating, Ventilation and Air Conditioning -something that you never think about until it doesn’t work properly.
Variable Frequency Drives VFD Basics
Wine Cellar Split System Basics. Definitions Split System – A cooling unit that “splits” the cooling coil and the condenser apart into two remote pieces.
ClimateMaster 2006 Rep Meeting ClimaDry™ Applications Jeff Hammond, Director of Marketing.
Air-Conditioning Control Systems
Engineered Products Make-Up Air for Heating and Cooling.
Engineer Presentation
ASHRAE Presentation: VRF Overview Mitsubishi Electric Presenter: Phone number ©2011 Mitsubishi Electric& Electronics USA, Inc.
Energy Recovery System Hadi Fattah Chris Korkuch Scott Lacey Ryan Neary Colin O’Neill.
Brett Graham Habegger Corporation Midwest Regional Sustainability Summit May 1, 2015.
COMMERCIAL REFRIGERATION
Objectives Finish with Multizone Systems
Refrigeration and Heat Pump Systems Refrigeration systems: To cool a refrigerated space or to maintain the temperature of a space below that of the surroundings.
An intelligent VAV zoning system
Brought to you by: Connecticut Energy Code Frederick F. Wajcs Senior Energy Engineer Northeast Utilities February 10, 2011.
ERMS- Energy Recovery Module. The module uses an Air Exchange ERC energy recovery wheel to recovery waste heat/cooling from the exhaust air stream and.
MCS’S MAGNUM DIAGNOSTICS PACKAGE Visit us at
Air Handler Terminology
Air Handler Terminology
Packaged Rooftop Air Conditioning Unit Presents the.
Roof Top Unit Overview (MAGNUM) Visit us at Revision- 12/17/2015.
HEATING AND COOLING SYSTEMS
Greenbriar East Elementary School Fairfax, Virginia Michelle L. Siano Mechanical Option Spring 2005 Senior Thesis.
Introduction to Energy Management. Week/Lesson 13 Control Strategies for Occupant Comfort.
Objectives Propose residential system related final project –Compare VAV systems with DOAS systems.
What makes up a Unico System
Michael Reilly, Jr. – Mechanical Option Advisor – James Freihaut, PhD & Dustin Eplee The Pennsylvania State University Nassau Community College Life Sciences.
WELCOME. Glycol Refrigeration A most basic definition of refrigeration is taking heat from someplace we don’t want it and moving it to someplace where.
HVAC Energy Efficiency using Mass Flow and Building Pressurization Jay Richardson Professional Supply, Inc.
James McIntyre VRF Training Manager V5 Key Components.
WSHP Systems 1.
Maria’s Restaurant Chapter 2 Section 6
. Level 3 Air Conditioning Inspections for Buildings
SNS COLLEGE OF ENGINEERING Coimbatore-107 Subject: Thermal Engineering
SNS COLLEGE OF ENGINEERING Coimbatore-107 Subject: Thermal Engineering
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
BUILDING HEATING AND COOLING
Story of No-Cost Energy Savings at Ohio Union
HVAC Basics Arkan Arzesh HVAC – Heating, Ventilation, Air-conditioning.
New Options for DryCool Products
New Air Handler Platform
Indoor Pool Design and Dehumidification
Munters DOAS, Chilled Beams and VRV
The Refrigeration Cycle (Air Conditioners)
Energy Efficiency in District Coiling System
Munters DOAS and Chilled Beams
Cheryl Hughes Regional Sales Manager October 6, 2015
Variable Frequency Drive (VFD)
Roof Top Unit Overview (MAGNUM)
Variable Refrigerant Volume
Factory Options, Accessories & Economizers
Loop Water Controller Overview
Air Conditioning System-1
VITALITY Large Splits Johnson Controls PowerPoint Guidelines | July 21, 2009.
INNOVATION lab MEP MECHANICAL/ELECTRICAL/PLUMBING :
FBE03: Building Construction & Science
Dunham Bush Air Cooled Package
Objective Revie the Cooling Cycle Learn about air distribution systems
‘‘ BUILDING AUTOMATION’’
Presentation transcript:

Engineering Presentation 1 Engineering Presentation February 28, 2017 By: Joe Finkam 11/16/2018

What is iAIRE? Company that deals with outside air 2 Company that deals with outside air Headquartered in Indianapolis, IN Manufacturing in Orlando, FL Patented technology How to reduce amount of outside air while maintaining or improving indoor air requirements and delivering on-going operating utility savings

What does iAIRE make? Ionization devices 3 Ionization devices Economizers w/our patented technology ERV’s Flow monitoring equipment Dedicated outside air units RTU modifications

Ionization Cleans air Low cost Low power Long life Ion block 4 Cleans air Low cost Low power Long life Ion block Packaged units Ability to reduce outside air via ASHRAE 62

Ionization 5

Economizer Controller Packages 6 Can give the ability to spec a controller that utilizes patent pending technology Ionization VOC sensor CO2 sensor Default is 0 outside air 2/3 reduction in outside air Cleaner indoor air conditions

Economizers 6 Carrier economizers Size 3 horizontal 3 vertical 3-6 ton 7 6 Carrier economizers 3 horizontal 3 vertical Size 3-6 ton 7-12.5 ton 15-25 ton

ERV’s Both mated and stand alone ERV’s Utilized Airxchange wheels 8 Both mated and stand alone ERV’s Utilized Airxchange wheels Mated units are hurricane & seismic rated

Flow Monitoring 9 Ebtron and other technologies are phenomenally accurate in controlled environments – This doesn’t exist in installed HVAC Ability to monitor CFM in a premade duct piece Making RTU hoods with flow control built into hood Ease of installation and accuracy once installed

How do DOAS units work 10 Does everyone understand how hot gas reheat works? Why do major OEM’s have their units discharge off the evaporator coil at 55 degrees?

How do DOAS units work 11

How do DOAS units work 12 DOAS units control humidity 1st and temperature 2nd. Control leaving air temperature coming off of the evaporator coil to control humidity Utilize modulating hot gas reheat to control temperature If you want to control a space at 68 degrees and 50% relative humidity, what would you need to do

What is offered? EconoDRY kit Up to 50% Outside Air Reheat Coil with ON/OFF Hot Gas Control Many times is installed with a Rawal valve kit ultraDRY 3 Up to 50% Outside Air Capacity reduction via RAWAL device Reheat Coil with modulating Hot Gas Control Ability to use standard humidistat and have night set back ultraDRY 0% to 100% Outside Air Capacity reduction via RAWAL device Reheat Coil with Modulating Control VFD on AHU Fan Motor Space or Discharge Air control Please explain what Ultra dry 100% outside air for indoor air quality 100% outside air for exhaust makeup Modulating outside air for demand ventilation Discharge air or space temperature and humidity control Roof top package units • Commercial split systems Custom built-up systems 11/16/2018

ultraDRY Outside air unit 3-150 ton units Built on Carrier platform 14 Outside air unit 3-150 ton units Built on Carrier platform Package RTU & split systems All electric Gas heat Heat pumps

ultraDRY Part Number 15

Options 16 Ionization – Reduce DOAS size using ASHRAE calcs ultraGUARD Coatings – Coastal corrosion protection for Condenser only, All Coils, or Entire Unit. ERV - Optional ERV (iAIRE brand) using Airxchange wheel (mated or bolt on) Motorized OA Dampers BACNet Interface Double Wall Construction – R-16 insulated SS Drain Pan SS Gas Heat Exchanger Non-Powered or Powered Service Outlet Disconnect – Switched or Fused Split Power Disconnect Smoke Detectors – Supply or RA Low Ambient Kits 365 Day Timer Condensate Control per Code MORE List ionization as an option.

How it works 3 Configurations Discharge air control model (DAT) 17 3 Configurations Discharge air control model (DAT) Space temperature and humidity control model (SAT) ultraDRY3 control model

RTU Modifications Modulating gas heat Control heat 18 Modulating gas heat Control heat Possibly add more gas than usual from Carrier factory

RTU Modifications Modulating compressor capability 19 Modulating compressor capability Rawal valve installation Less mechanical issues than variable speed compressor More modulating steps

RTU Modifications VAV RTU capability Split power Modulating compressor 20 VAV RTU capability Modulating compressor Low ambient control Supply fan VFD Supply fan controller (Either duct static or building pressure control) Modulating gas heat capacity Split power Emergency back up generator running supply fan

RTU Modifications High static fan applications On/off hot gas reheat 21 High static fan applications On/off hot gas reheat Double wall SS drain pan VFD installation Water coils

Conclusion 22 1.) Industry leading lead time 2.) Sell a complete package on most projects 3.) Wide array of custom modifications (Indoor package units, WSHP, etc.) 4.) Low cost 5.) iAIRE covers 1 year parts/5 year compressor warranty 6.) Factory service support 7.) Full technical training for contractors Car dealerships Movie theaters Classrooms Gymnasiums Spas restaurants

Contact Information 23 Insert Distributor & Rep Name iAIRE LLC www.myiaire.com Customer Service: 844-348-9168 sales@myiaire.com Joe Finkam jfinkam@myiaire.com Cell: 317-614-5371