NICET Fire Alarm Tech Level 1 Practice Test # 13

Slides:



Advertisements
Similar presentations
Denver Fire Alarm Test FUNDAMENTAL, POWER SUPPLIES, CIRCUITS, INSPECTIONS, TESTING and MAINTENANCE.
Advertisements

Initiating Devices Manual Fire Alarm Boxes Ionization Smoke Detectors
Denver Fire Alarm Test Preparation Speed Drill © Ted Smitty Smith 2013.
NFPA 72 - National Fire Alarm Code Chapter 4 - Notification Appliances
State Fire Marshal Question and Answer Session with the Louisiana Automatic Fire Alarm Association March 19, 1999.
NFPA National Fire Alarm & Signaling Code
Ted “Smitty” Smith  I have included in the following slides some key sections from each of the codes you will primarily encounter on the test. I recommend.
Fire Alarm System Notification Appliances
NICET Exam Prep Level II, Class 3.
Chapter 19 Electrical Plans.
Inspection and Testing of Fire Alarm Systems (ITFAS)
FIRE ALARM SYSTEMS AND FUNDAMENTALS
WELCOME DBI & SFFD Meet the Pros October 11, 2007.
Ted “Smitty” Smith  This slide show contains multiple timed questions. All questions can be answered using the International Fire Code, The National.
Chapter 14: Inspection and Maintenance
© 2012 Ted “Smitty” Smith  This slide show contains multiple timed questions. All questions can be answered using the International Fire Code and the.
Two Minute Drill #8 Copyright 2005 Ted "Smitty" Smith Practice Code Look Up.
Two Minute Drill #10 Copyright 2005 Ted "Smitty" Smith.
Safety Training Presentation
Calculation Speed Drill # NEC
Copyright 2008 Ted "Smitty" Smith.  Left click on the presentation ICON located at the bottom of the slide directory to the left of the this slide. 
2008 Code Drills (C) Copyright 2008 Ted "Smitty" Smith 1 Smitty’s Speed Drills.
Fire Alarm Verification CAN/ULC-S561-03
Fire Protection Systems for Facility Managers Michael Salazar NICET Level 2.
Carbon Monoxide Detection: Code and Legislation Updates
Fire Protection Systems Chapter 9 IBC 9th Edition Amendments
2011 Changes Two Minute Drill
Smitty’s Two Minute Drills
NICET Fire Alarm Tech Level 1 Practice Test
NICET Fire Alarm Tech Level 1 Practice Test # 4
Smitty’s Two Minute Drill Overcurrent Protection
NICET Fire Alarm Tech Level 1 Practice Test # 9
NICET Fire Alarm Tech Level 1 Practice Test # 6
Smitty’s Two Minute Drill Mixed Content -05
AUTOMATIC SPRINKLERS.
Smitty’s Two Minute Drill #9: Special Occupancies
Smitty’s Super Speed Drill for Memorization No. 2
Toolbox talk on fire risk assessment by Marc Cork
Emergency Lighting Design, Inspection and Maintenance Requirements
NICET Fire Alarm Tech Level 1 Practice Test # 2
NICET Fire Alarm Tech Level 1 Practice Test # 3
Emergency Electrical Power Supply for Buildings
Chapter 19 Electrical Plans.
Calculations: Transformers and Service Conductor Calculations
Smitty’s Super Speed Drill for Memorization No
NICET Fire Alarm Tech Level 1 Practice Test # 10
Smitty’s Two Minute Drill #1: Feeders and Branch Circuits
Presented by: Tim Knisely
Fire Alarm Tech Practice Test # 16 NICET
FACILITY DOCUMENT REVIEW TRAINING
Smitty’s Two Minute Drill Grounding and Bonding
Smitty’s Super Speed Drill for Memorization No. 2 Resistor Color Codes
2008 Code Drills Health Care Facilities
Fire Prevention Coffee Break Training
Fire Alarm Practice Drill # 11 Denver Fire Department Journeyman Installer License Test © Ted Smith 2017.
Smitty’s Two Minute Drill Services, Feeders, and Branch Circuits 1
Two Minute Drill – Residential 3
Smitty’s Two Minute Drill Varied Number 7
FIRE ALARM DRILL 26 © Ted Smith 2017.
Smitty’s Two Minute Drill General Knowledge
Smitty’s Two Minute Drill The BIG 5 Drill 1
Two Minute Drill – Residential 2
Smitty’s Two Minute Drill General Knowledge 2
Smitty’s Super Speed Drill for Memorization 8 Forms of Waste
Denver Fire Depart. License Fire Alarm Practice Test # 12
Fire Protection Documentation
NICET Fire Alarm Tech Level 1 First Aid, CPR, AED #2
Presentation transcript:

NICET Fire Alarm Tech Level 1 Practice Test # 13 © Ted Smith 2017

They will let you use your code book on the test and it can have highlights in it. AFTER YOU ARE DONE WITH THE QUIZ. GO THROUGH AND FIND ALL THE CORRECT ANSWERS AND THEN HIGHLIGHT THEM IN YOUR CODE BOOK. YOU WILL FIND THEM FASTER ON THE TEST THAT WAY. I BELIEVE YOU WILL HAVE MANY QUESTIONS ON THE TEST WHERE THE ANSWER COMES FROM A PLACE YOU HAVE HIGHLIGHTED.

Instructions Be sure to place this presentation in Slide Show Mode if it is not already in that mode before proceeding The purpose of this drill is to help you improve your skill at finding answers to questions using the applicable fire codes and also to help increase your knowledge of the Fire Alarm codes. Each slide will contain a question. The question will remain in the screen for a period of 2 minutes. At the end of the two minutes, a notification will sound and the slide will transition to the next slide which will have the correct answer to the question. After 15 seconds the next question will appear and the process will continue. During the test do not worry about the correct answers when those slide appear. You will be given an opportunity to review the answers with out the time at the end of the test. Click on the slide to start the timer and begin the test

First Aid Select three of the following items which are symptoms of heat exhaustion. Confusion Muscle or abdominal cramps Pale skin No sweating

A, B and C

NFPA 72 2. Which of the following methods of mounting a smoke detector in an underfloor space is not allowed? A B C D

D. Annex A Figure A.17.7.3.2.1

NFPA 72 3. A smoke detector mounted on a ceiling near a return air opening should be mounted at least ______________ from the return air opening. 6 inches 12 inches 36 inches 48 inches

C. 36 inches Annex A A.17.7.4.1

NFPA 72 4. A strobe light used as a visual notification appliance in sleeping area shall have a minimum candela rating of ________ if it is mounted less than 24 inches from the ceiling because it might be in a layer of smoke in the event of a fire. 177 110 212 187

A. 177 Annex A A.18.5.5.7.2

NFPA 72 5. For visual notification appliances, the pulse duration shall be defined as the time interval between _________ and _________ points of 10 percent maximum signal. Final and pre-signal Initial and Final Pre-signal and Final Pre-current firing and Initial

B. Initial and Final 18.5.3.3

NFPA 72 6. The semi- annual control valve switch test shall be done by operating the valve and ensuring receipt of a signal within the first two revolutions of the handwheel or within _____________ of the travel distance ¼ 1/5 ½ 2/3

B 1/5 T14.4.3.2 Item 17 (j)(1)

NFPA 72 7. Which drawings or documents shall form the basis for the record as-built drawings? Emergency Response Plan Documentation Evaluation Documentation Shop Drawings Record of Completion

C. Shop Drawings 7.4.3

NFPA 72 8. A record copy of the site specific software for software based systems shall be delivered to the ________________ as part of completion documentation. Authority Having Jurisdiction Owner or owners representative Installing contractor General contractor

B Owner or owners representative 7.5.3

NFPA 72 9. A copy of the site specific software shall be stored __________________ in nonvolatile, nonerasable, non-rewritable memory. At the central station At the local fire house On site At the corporate office of the owner

C. On site 7.5.7.2

NFPA 72 10. The failure of any telephone line connected to a DACR due to loss of line voltage shall be annunciated visually only in the supervising station. True False

B. False 26.6.4.2.2 (B)

NFPA 72 11. The maximum duration between the initiation of an alarm signal at the protected premises, transmission of the signal, and subsequent display and recording of the alarm signal at the supervising station shall not exceed ________ seconds. 10 seconds 60 seconds 90 seconds 120 seconds

C. 90 seconds 26.6.3.8

NFPA 72 12. A corridor that is 12 feet wide and 180 feet long shall have a minimum of _____________ visual notification appliances installed? 2 4 5 3

D. 3 18.5.5.5.5 One will need to be at both ends at 15 feet from end. That leaves 150 feet of corridor in the middle. If a device is placed in the middle that would be only 75 between either of the end devices and the middle device.

NFPA 72 13. When performing the annual test of an air sampling smoke detector, a listed and labeled product shall be used by testing from the ____________ sampling port or point on each pipe run. Midpoint Return Supply End

D. End Table 14.4.3.2 Item 17 (g)(4)

NFPA 72 14. The primary power supply shall be visually inspected at least once per _________ for fire alarm systems which are unmonitored for alarm, supervisory and trouble signals. Yearly Quarterly Monthly Weekly

D. Weekly Table 14.3.1 Item 2(b)(4)

NFPA 72 15. Most nickel-cadmium rechargeable battery used in fire alarm systems today are available in nominal voltages of _________ volts per cell. 6 volts 2.3 volts 1.42 volts 3.1 volts

C. 1.42 volts Annex A A. 10.6.10(2)

END of QUIz. THE TIME WILL STOP NOW END of QUIz. THE TIME WILL STOP NOW. PLEASE CLICK ON THE SLIDE TO CONTINUE WITHOUT THE TIMER AND REVIEW EACH QUESTION.

First Aid Select three of the following items which are symptoms of heat exhaustion. Confusion Muscle or abdominal cramps Pale skin No sweating

A, B and C

NFPA 72 2. Which of the following methods of mounting a smoke detector in an underfloor space is not allowed? A B C D

D. Annex A Figure A.17.7.3.2.1

NFPA 72 3. A smoke detector mounted on a ceiling near a return air opening should be mounted at least ______________ from the return air opening. 6 inches 12 inches 36 inches 48 inches

C. 36 inches Annex A A.17.7.4.1

NFPA 72 4. A strobe light used as a visual notification appliance in sleeping area shall have a minimum candela rating of ________ if it is mounted less than 24 inches from the ceiling because it might be in a layer of smoke in the event of a fire. 177 110 212 187

A. 177 Annex A A.18.5.5.7.2

NFPA 72 5. For visual notification appliances, the pulse duration shall be defined as the time interval between _________ and _________ points of 10 percent maximum signal. Final and pre-signal Initial and Final Pre-signal and Final Pre-current firing and Initial

B. Initial and Final 18.5.3.3

NFPA 72 6. The semi- annual control valve switch test shall be done by operating the valve and ensuring receipt of a signal within the first two revolutions of the handwheel or within _____________ of the travel distance ¼ 1/5 ½ 2/3

B 1/5 T14.4.3.2 Item 17 (j)(1)

NFPA 72 7. Which drawings or documents shall form the basis for the record as-built drawings? Emergency Response Plan Documentation Evaluation Documentation Shop Drawings Record of Completion

C. Shop Drawings 7.4.3

NFPA 72 8. A record copy of the site specific software for software based systems shall be delivered to the ________________ as part of completion documentation. Authority Having Jurisdiction Owner or owners representative Installing contractor General contractor

B Owner or owners representative 7.5.3

NFPA 72 9. A copy of the site specific software shall be stored __________________ in nonvolatile, nonerasable, non-rewritable memory. At the central station At the local fire house On site At the corporate office of the owner

C. On site 7.5.7.2

NFPA 72 10. The failure of any telephone line connected to a DACR due to loss of line voltage shall be annunciated visually only in the supervising station. True False

B. False 26.6.4.2.2 (B)

NFPA 72 11. The maximum duration between the initiation of an alarm signal at the protected premises, transmission of the signal, and subsequent display and recording of the alarm signal at the supervising station shall not exceed ________ seconds. 10 seconds 60 seconds 90 seconds 120 seconds

C. 90 seconds 26.6.3.8

NFPA 72 12. A corridor that is 12 feet wide and 180 feet long shall have a minimum of _____________ visual notification appliances installed? 2 4 5 3

D. 3 18.5.5.5.5 One will need to be at both ends at 15 feet from end. That leaves 150 feet of corridor in the middle. If a device is placed in the middle that would be only 75 between either of the end devices and the middle device.

NFPA 72 13. When performing the annual test of an air sampling smoke detector, a listed and labeled product shall be used by testing from the ____________ sampling port or point on each pipe run. Midpoint Return Supply End

D. End Table 14.4.3.2 Item 17 (g)(4)

NFPA 72 14. The primary power supply shall be visually inspected at least once per _________ for fire alarm systems which are unmonitored for alarm, supervisory and trouble signals. Yearly Quarterly Monthly Weekly

D. Weekly Table 14.3.1 Item 2(b)(4)

NFPA 72 15. Most nickel-cadmium rechargeable battery used in fire alarm systems today are available in nominal voltages of _________ volts per cell. 6 volts 2.3 volts 1.42 volts 3.1 volts

C. 1.42 volts Annex A A. 10.6.10(2)