Electrical Engineering Department

Slides:



Advertisements
Similar presentations
Demand Response: The Challenges of Integration in a Total Resource Plan Demand Response: The Challenges of Integration in a Total Resource Plan Howard.
Advertisements

1 FREQUENCY CONTROL -- Bhanu Bhushan -- (April, 2011)
Understanding Electrical TransmissionDemonstration A1 A Guide to the National Grid Transmission Model Demonstration A1 How is electricity generated and.
Objectives Control Terminology Types of controllers –Differences Controls in the real world –Problems –Response time vs. stability.
Design of LFC using Optimal Control Theory The optimal controller is designed to minimize the quadratic performance index of the following form For linear.
FREQUENCY CONTROL DURING BLACK START OPERATIONS
Announcements Be reading Chapter 6, also Chapter 2.4 (Network Equations). HW 5 is 2.38, 6.9, 6.18, 6.30, 6.34, 6.38; do by October 6 but does not need.
Active Power and Frequency Control
Rudolf Wieser, Matthias Baechle, Valerijs Knazkins – ATPE
PRESENTATION FREQUENCY CONTROL
Ee392n - Spring 2011 Stanford University Intelligent Energy Systems 1 Lecture 3 Intelligent Energy Systems: Control and Monitoring Basics Dimitry Gorinevsky.
Control System Instrumentation
EKT214 - ANALOG ELECTRONIC CIRCUIT II
Three-Phase ac Voltage Generation
Governor Response Sequence Bob Green Garland Power and Light ERCOT Future AS Workshop January 20, 2014.
ET2105 Electrical Power System Essentials
1 Introduction to Power Systems Expensive! Influential!Intrusive! Source: Riadh W. Y. Habash, Electromagnetic Fields and Radiation, Marcel Dekker, New.
Where: I T = moment of inertia of turbine rotor.  T = angular shaft speed. T E = mechanical torque necessary to turn the generator. T A = aerodynamic.
21 st May 2015 SMARTGREENS 2015 Lisbon, Portugal Lane Department of Computer Science and Electrical Engineering West Virginia University Analyzing Multi-Microgrid.
ELG4125 Transmission and Distribution Systems
1 Cheng-Ting Hsu Chao-Shun Chen Islanding Operations for the Distribution Systems with Dispersed Generation Systems Department of Electrical Engineering.
Book Adaptive control -astrom and witten mark
Conclusions Innovative application of induction and synchronous generators in autonomous small hydropower plant Prof. M.T.E. Kahn NeuroMorphoGenics/NMG.
Announcements Please read Chapter 4 HW 1 is due now
FREQUENCY CONTROL AND AUTOMATIC GENERATION CONTROL
Leader-Follower Framework For Control of Energy Services Ali Keyhani Professor of Electrical and Computer Engineering The Ohio State University
Clemson University Electric Power Research Association CHANDANA BOMMAREDDY CLEMSON UNIVERSITY DG VOLTAGE CONTROL IN AN ISLANDING MODE OF OPERATION.
Banc d’(Bench) Essais pour(Tests for) Régulateurs(Regulators) Turbines et(Turbines) Alternateurs(Alternators)
Thesis Topic Load Frequency Control in Power System.
Advanced Control of Marine Power System
Feedback Control system
Marc Langevin, eng., Ph.D. Marc Soullière, tech. Jean Bélanger, eng. * A Real-Time Regulator, Turbine and Alternator Test Bench for Ensuring Generators.
Introduction to Power Supplies
Lecture 25: Implementation Complicating factors Control design without a model Implementation of control algorithms ME 431, Lecture 25.
Steady State Analysis Of A Microgrid Connected To A Power System
FREQUENCY-POWER CHARACTERISTICS OF SYNCHRONOUS GENERATOR
Optimal Power Flow- Basic Requirements For Real Life.
-- Bhanu Bhushan -- < > (August, 2011)
1 © A. Kwasinski, 2015 Cyber Physical Power Systems Fall 2015 Security.
GENERAL BACKGROUND AND SPEED GOVERNORS
7th International Scientific Conference on “Energy and Climate Change”
Distribution Systems-General
Name Of The College & Dept
REACTIVE POWER COMPENSATION
Optimal Power Flow- Basic Requirements For Real Life Their Problems And Solutions.
Power Plant Construction and QA/QC Section 5.3 – Turbine and Engine Governors Engineering Technology Division.
President UniversityErwin SitompulSMI 1/1 Dr.-Ing. Erwin Sitompul President University Lecture 1 System Modeling and Identification
Advanced control strategies. CONTROL SYSTEMS The process parameters which are measured using probes described in the previous sections may be controlled.
Control Engineering. Introduction What we will discuss in this introduction: – What is control engineering? – What are the main types of control systems?
BIOMASS SUPPORTED SOLAR THERMAL HYBRID POWER PLANT
SMJE 2103 Synchronous Generator. Scope of discussion 1)Construction 2)Rotation speed 3)Generated voltage 4)Equivalent circuit 5)Power and Torque 6)Testing.
MISS. RAHIMAH BINTI OTHMAN
RECENT TRENDS IN POWER SYSTEMS
0 Balanced 3 Phase (  ) Systems A balanced 3 phase (  ) system has three voltage sources with equal magnitude, but with an angle shift of 120  equal.
 The common type of wind power generators are squirrel cage induction generator (SCIG),doubly fed induction generator (DFIG)  For more secure and.
Introduction to Electric Power System and A. C. Supply
The Clutch Control Strategy of EMCVT in AC Power Generation System
Chapter 1: Overview of Control
IG BASED WINDFARMS USING STATCOM
Control Schemes for Distribution Grids with Mass Distributed Generation AUTHOR: UMAIR SHAHZAD.
Economic Operation of Power Systems
ECE 382. Feedback Systems Analysis and Design
Introduction to Control Systems Objectives
Automatic Generation Control (AGC)
Linear Control Systems
Control System Instrumentation
Student’s Name with USN No.
Introduction to Process Control
Overview of Control System
ECE 476 POWER SYSTEM ANALYSIS
Presentation transcript:

Electrical Engineering Department Graduation Project II Electrical Engineering Department AGC of UAE Power System Advisor: Professor. Abdullah Ismail Done by: Awad Saleh Abdulla Al.Harthi 200337916 Muhammed Usame Suzen 200337980 Aadel Ahmed Al.Mehrezi 200402268    

Outline Introduction to the Project. Automatic Generation Control. Introduction to Power Generation Control. Introduction to AGC. Safety Ethics and Environmental Affects. Load Frequency Control. LFC model for single power system area. LFC model for two interconnected power system areas. LFC model for three interconnected power system areas. Automatic Voltage Regulator. Cost Estimation. Conclusion.

Project Purpose To perform measurement, modeling, analysis, and control design of voltage and frequency of UAE power systems.

Project Objectives Measurement and modeling of UAE power systems voltage and frequency variations. Computer modeling and analysis of the AGC including AVR and LFC functions. Design controllers for UAE power system voltage and frequency variations.

Project Status GPI: GPII: LFC Model of Multi-Areas Interconnected Power System. Study the frequency behavior of each power system area. Study the power exchange between the interconnected power system areas. GPII: Design the PID controller. Automatic Voltage Regulation(AVR) of multi-areas interconnected power system.

Safety Ethics The safety of employees, contractors, visitors and the general public shall be the prime consideration. Continuity of supply. Security of apparatus or plant.

Environmental Effects Each such system has advantages and disadvantages, but many of them pose environmental concerns. The efficiency of some of these systems can be improved by cogeneration (combined heat and power) methods.

AGC

Introduction to the power generation system It is a system where the power is being generated transmitted, and distributed from the main power station through substations, to different areas using overhead or underground power lines.

Power Generation Station Components Governor (Actuator). Turbine. Generator.

Governor A valve that controls the amount of fuel or steam running into the system. Tg: governor time constant. Kg: governor constant. ∆Pg: power generated from the governor. ∆Pc: Speed Changer. 1/R: Speed or droop Regulator.

Turbine A mechanical system which converts thermal energy provided by the governor to mechanical energy. Tt: Turbine time constant. Kt: Turbine constant. ∆Pg: energy input power. ∆Pt: output mechanical power.

Generator The generator produces electrical energy with certain voltage and frequency. Kp: Gain constant. Tp: Generator time constant. ∆Pd: load disturbance. ∆f: frequency change. ∆Pt: Power coming from the turbine.

WHAT DOES AGC MEAN? AGC: Automatic Generation Control. Process that controls the limits of the frequency and voltage variations. Power system stability can be achieved by controlling the frequency and the voltage regulation.

Purpose of AGC To maintain power balance in the system. Make sure that operating limits are not exceeded:- Generators limit Tie-lines limit Make sure that system frequency is constant (not change by load) [ 50 HZ in UAE]. To maintain each unit's generation at the most economic value.

AGC Advantages Power reliability. Safety. Minimizing the cost with getting a good efficiency with a least losses.

AGC Parts and Connections with the Power Generation

Load Frequency Control

Load Frequency Control Mechanical power is produced by a turbine and delivered to a synchronous generator serving different users. The frequency of the current and voltage waveforms at the output of the generator is mainly determined by the turbine steam flow. LFC is to control the real power ‘P’(MW).

Load Frequency Control modeling methods State Variable: It is an element of the set of variables that describe the state of dynamic systems. system state vector rate of change of state of the system the input to the system the output

LFC Simulation LFC system was simulated in two scenarios: The first scenario is when the power plant doesn’t have any control system: Single power system area. Two interconnected power system areas. Three interconnected power system areas. In second scenario we applied PID controller to the plant: Models used in this problem: Model one which is a simple standard textbook model Model two which is a practical system from Um Al-Nar power station in Abu-Dhabi, UAE.

Model One

Model Two

PID Controller

Parallel PID Controller Parameters Effects

Simulation

Single Power System Area

Block Diagram of Model 1

Results of the Frequency ∆Frequency (Hz) Time (Second) As seen above in the figure the frequency response has two main problems; under-shoot, and steady-state error. These problems have been solved after we applied the suitable PID controller to the system.

PID Controller Design The design of the controller was based on the test and error methods where we did some iterations until we came up with the best design as shown in the figure down:

Model one Frequency Response Frequency (Hz) Without PID Time (Second) Frequency (Hz) With PID Time (Second)

Two Interconnected Power System Areas (M1/M1)

Input/output Configuration System Outputs Inputs 2 Area Power System Δf1 ΔPd1 Δf2 ΔPd2 ΔPt12

Without PID With PID

Frequency Response

Frequency (Hz) Time (Second) Frequency (Hz) Time (Second) Without PID Time (Second) Frequency (Hz) With PID Time (Second)

Transmission line response

Power (kW) Time (Second) Power (kW) Time (Second) Without PID Time (Second) With PID Power (kW) Time (Second)

Two Interconnected Power System Areas (M1/M2)

Frequency Response

Frequency (Hz) Time (Second) Frequency (Hz) Time (Second) Without PID Time (Second) Frequency (Hz) With PID Time (Second)

Transmission line response

Power (kW) Time (Second) Power (kW) Time (Second) Without PID Time (Second) Power (kW) With PID Time (Second)

Three Interconnected Power System Areas (M1/M1)

Power Plant Configuration M1 M1 Area3 Area1 ∆Pt31 ∆Pt12 ∆Pt23 M1 Area2

Frequency Response

Frequency (Hz) Time (Second) Frequency (Hz) Time (Second)

Transmission line response

Power (kW) Time (Second) Power (kW) Time (Second) Without PID Time (Second) With PID Power (kW) Time (Second)

Three Interconnected Power System Areas (M1/M2)

Frequency Response

Frequency (Hz) Time (Second) Frequency (Hz) Time (Second) Without PID Time (Second) Frequency (Hz) With PID Time (Second)

Transmission line response

Power (kW) Time (Second) Power (kW) Time (Second) Without PID Time (Second) With PID Power (kW) Time (Second)

AVR (Automatic Voltage Regulator)

Introduction to AVR Reactive Power (Q) is one of the two main elements in the power system must be controlled. This reactive power is closely related to the system voltage Any voltage error in the system is sensed, measured, and transformed into reactive-power command signal. The objective of the AVR is to keep the system terminal voltage at the desired value by means of feedback control

Generation System and AVR The block diagram above shows where the AVR is placed in the entire generation system.

AVR Simple Model KE=200 TE =0.05 KG=1 TG =0.2 KR=0.05 TR =0.05

AVR Simple Model with PID Amplifier Exciter Generator Sensor

AVR Simulation

Without PID With PID

AVR Result Analysis: The AVR system has only one main problem when it works without any control system that: - Under-shoot. To get rid of this problem, the parallel PID controller is the best choice. The design of the PID controller was done based on the test and error method. The suitable PID controller parameter are as shown in the previous slide.

Voltage Response

Delta V (voltage change) Without PID Delta V (voltage change) Time (Sec.) With PID Delta V (voltage change) Time (Sec.)

Cost Estimation PID controller costs around 272$/generation station. For instance, if we have 100 generation station in Abu-Dhabi: Total cost = (PID price) * (No. of generation stations) = 272($/G.S.) * 100 (G.S.) = 27200$

Conclusion AGC is a major control function within a utility’s energy control center, whose purpose is the tracking of load variations while maintaining system frequency, net tie-line interchanges, and optimal generation level close to scheduled values. Control of power systems becomes more difficult as the load increases during the time so, to solve this problem it’s recommended to design a system that controls the frequency variations using Proportional-Integral (PI) control, Robust control and Fuzzy control.

The Load Frequency Control is known as a continuous regulation of electric power systems frequency required to constantly balance the energy demanded by consumers. Changes in demand and/or supply can be observed by measuring the system's frequency. Its desired value is 50 Hz and any changes and increased demand will result in a frequency below 50 Hz and decreased demand in a frequency above 50 Hz. The LFC working in the system according to the power system load that continually undergoing change as individual loads fluctuate.

AGC system is affected by LFC more than AVR so if LFC system is not stable the AGC will be not stable as well. While if AVR system is not stable that doesn’t mean AGC will not be stable but it will depend on the whole system stability.

Abbreviations: AGC: Automatic Generation Control. LFC: Load Frequency Control. AVR: Automatic Voltage Regulator. G.S.: Generation Station.

Thanks for listening. Any Questions ??