Beam test of Silicon-Tungsten Calorimeter Prototype

Slides:



Advertisements
Similar presentations
SiW ECAL R&D in CALICE Nigel Watson Birmingham University For the CALICE Collab. Motivation CALICE Testbeam Calibration Response/Resolution MAPS Option.
Advertisements

CSC Test Beam Data Analysis Alexander Khodinov and Valeri Tcherniatine.
LC Calorimeter Testbeam Requirements Sufficient data for Energy Flow algorithm development Provide data for calorimeter tracking algorithms  Help setting.
Status of DHCAL Slice Test Data Analysis Lei Xia ANL-HEP All results preliminary.
Adil Khan Kyungpook National university Korea-Japan Joint ScECAL Group Meeting kobe University Japan 3 rd September 2010.
13/02/20071 Event selection methods & First look at new PCB test Manqi Ruan Support & Discussing: Roman Advisor: Z. ZHANG (LAL) & Y. GAO (Tsinghua))
Bulk Micromegas Our Micromegas detectors are fabricated using the Bulk technology The fabrication consists in the lamination of a steel woven mesh and.
W. Clarida, HCAL Meeting, Fermilab Oct. 06 Quartz Plate Calorimeter Prototype Geant4 Simulation Progress W. Clarida The University of Iowa.
Adding electronic noise and pedestals to the CALICE simulation LCWS 19 – 23 rd April Catherine Fry (working with D Bowerman) Imperial College London.
1 Study of the Tail Catcher Muon Tracker (TCMT) Scintillator Strips and Leakage with Simulated Coil Rick Salcido Northern Illinois University For CALICE.
A preliminary analysis of the CALICE test beam data Dhiman Chakraborty, NIU for the CALICE Collaboration LCWS07, Hamburg, Germany May 29 - June 3, 2007.
The first testing of the CERC and PCB Version II with cosmic rays Catherine Fry Imperial College London CALICE Meeting, CERN 28 th – 29 th June 2004 Prototype.
27 th May 2004Daniel Bowerman1 Dan Bowerman Imperial College 27 th May 2004 Status of the Calice Electromagnetic Calorimeter.
Anne-Marie Magnan Imperial College London CALICE Si-W EM calorimeter Preliminary Results of the testbeams st part On behalf of the CALICE Collaboration.
Thursday, November 7th ECFA meeting - Valencia - A.-M. Magnan 1 CALICE Summary of 2006 testbeam for the ECAL Anne-Marie MAGNAN Imperial College London.
Michele Faucci Giannelli TILC09, Tsukuba, 18 April 2009 SiW Electromagnetic Calorimeter Testbeam results.
LCWS2002G/H Joint Session Fabrication of a Silicon Pixel/Pad for dE/dx Measurement H. Park (Kyungpook National U.) I.H. Park (Ewha Womans U.)
Sept. 24, Status of GEM DHCAL Jae Yu For GEM-TGEM/DHCAL Group Sept. 24, 2010 CALICE Collaboration Meeting Univ. Hassan II, Casablanca Introduction.
High Energy Beam Test and Simulation of Silicon-Tungsten Calorimeter Test Module Shinwoo Nam (Ewha Womans University) On behalf of Ewha Womans University:
06/03/06Calice TB preparation1 HCAL test beam monitoring - online plots & fast analysis - - what do we want to monitor - how do we want to store & communicate.
CERN Beam Test of Silicon-Tungsten Calorimeter Test Module Shinwoo Nam (Ewha Womans University) On behalf of Ewha Womans University: S.J. Baek, H.J. Hyun,
SPiDeR  SPIDER DECAL SPIDER Digital calorimetry TPAC –Deep Pwell DECAL Future beam tests Wishlist J.J. Velthuis for the.
The CALICE Si-W ECAL - physics prototype 2012/Apr/25 Tamaki Yoshioka (Kyushu University) Roman Poschl (LAL Orsay)
The Scintillator ECAL Beam Test at FNAL Adil Khan International Linear Collider Workshop 2010 LCWS10 & ILC10, Beijing, China CALICE Scintillator ECAL group.
The Scintillator ECAL Beam Test at FNAL K. Kotera, Shinshu-u, 1st October 2009 CALICE Scintillator ECAL group; Kobe University, Kyungpook University, the.
SiW ECAL Technological Prototype Test beam results Thibault Frisson (LAL, Orsay) on behalf of the CALICE collaboration.
Light Calibration System (LCS) Temperature & Voltage Dependence Option 2: Optical system Option 2: LED driver Calibration of the Hadronic Calorimeter Prototype.
Montpellier, November 15, 2003 J. Cvach, TileHCAL and APD readout1 TileHCAL- fibre readout by APD APDs and preamplifiers Energy scan with DESY beam –Energy.
Lepton Collider Increased interest in high energy e + e - collider (Japan, CERN, China) STFC funded us for £75k/year travel money in 2015 and 2016 to re-
GLD Calorimetry 2005/Mar/03 K. Kawagoe / Kobe-U. Introduction Current design –To be optimized for Particle Flow Algorithm (PFA) aiming at 30%/sqrt(E)
Plan for 2009 CALICE beam test with ScECAL + AHCAL + TCMT Jan-28 th CALICE TB Satoru Uozumi (Kobe)
Shashlyk FE-DAQ requirements Pavel Semenov IHEP, Protvino on behalf of the IHEP PANDA group PANDA FE-DAQ workshop, Bodenmais April 2009.
Apollo Go, NCU Taiwan BES III Luminosity Monitor Apollo Go National Central University, Taiwan September 16, 2002.
1 The CALICE experiment at MTBF (FNAL) summary of a fruitful test beam experiment Erika Garutti (DESY) On behalf of CALICE.
11/18/2016 Test beam studies of the W-Si tracking calorimeter for the PHENIX forward upgrade Y. Kwon, Yonsei Univ., PHENIX.
FSC Status and Plans Pavel Semenov IHEP, Protvino on behalf of the IHEP PANDA group PANDA Russia workshop, ITEP 27 April 2010.
CALICE Tungsten HCAL Prototype status Erika Garutti Wolfgang Klempt Erik van der Kraaij CERN LCD International Workshop on Linear Colliders 2010, October.
5-9 June 2006Erika Garutti - CALOR CALICE scintillator HCAL commissioning experience and test beam program Erika Garutti On behalf of the CALICE.
ScECAL Beam FNAL Short summary & Introduction to analysis S. Uozumi Nov ScECAL meeting.
Reconstructing energy from HERD beam test data Zheng QUAN IHEP 3 rd HERD work shop Xi’an, 20 Jan
Idea for next data taking at FNAL Dec-14 th 2008 ScECAL S. Uozumi (Kobe)
Calice Meeting Argonne Muon identification with the hadron calorimeter Nicola D’Ascenzo.
Geant4 Tutorial, Oct28 th 2003V. Daniel Elvira Geant4 Simulation of the CMS 2002 Hcal Test Beam V. Daniel Elvira Geant4 Tutorial.
LHCf Detectors Sampling Calorimeter W 44 r.l, 1.6λ I Scintilator x 16 Layers Position Detector Scifi x 4 (Arm#1) Scilicon Tracker x 4(Arm#2) Detector size.
Quartz Plate Calorimeter Prototype Hardware & Preliminary Test Beam Data Anthony Moeller The University of Iowa.
Performance of Scintillator-Strip Electromagnetic Calorimeter for the ILC experiment Satoru Uozumi (Kobe University) for the CALICE collaboration Mar 12.
18 Sep 2008Paul Dauncey 1 DECAL: Motivation Hence, number of charged particles is an intrinsically better measure than the energy deposited Clearest with.
DHCAL Jan Blaha R&D is in framework of the CALICE collaboration CLIC08 Workshop CERN, 14 – 17 October 2008.
Manqi Ruan Discussing & Support: Roman, Francois, Vincent, Supervisor: Z. ZHANG (LAL) & Y. GAO (Tsinghua)) DQ Check for CERN Test.
Energy Reconstruction in the CALICE Fe-AHCal in Analog and Digital Mode Fe-AHCal testbeam CERN 2007 Coralie Neubüser CALICE Collaboration meeting Argonne,
Front-end Electronic for the CALICE ECAL Physic Prototype Christophe de La Taille Julien Fleury Gisèle Martin-Chassard Front-end Electronic for the CALICE.
1 Methods of PSD energy calibration. 2 Dependence of energy resolution on many factors Constant term is essential only for energy measurement of single.
CALICE, Shinshu, March Update on Micromegas TB analysis Linear Collider group, LAPP, Annecy CALICE collaboration meeting 5-7 March 2012, Shinshu,
Experimental Method: 2 independent detectors on both sides of IP
the CALICE test beam set-up and running experience
MPC-Ex Project in Korea
CALICE scintillator HCAL
Panagiotis Kokkas Univ. of Ioannina
Detection of muons at 150 GeV/c with a CMS Preshower Prototype
ILC Detector Activities in Korea
ScECAL+AHCAL+TCMT Combined Beam FNAL
   Calorimetry et al.    SUMMARY 12 contributions Tile HCAL
Use of Beam Loss Monitor type detectors in CNGS muon station
On behalf of CEPC calorimeter working group
Rick Salcido Northern Illinois University For CALICE Collaboration
Michele Faucci Giannelli
Experimental Method: 2 independent detectors on both sides of IP
Steve Magill Steve Kuhlmann ANL/SLAC Motivation
LC Calorimeter Testbeam Requirements
Presentation transcript:

Beam test of Silicon-Tungsten Calorimeter Prototype 7th ACFA workshop, Taipei 2004/11/10 Youngdo Oh (Kyungpook National University) On behalf of Ewha womans University: S.J. Baek, H.J. Hyun, A.L. Jeong, S.W. Nam, I.H. Park, J. Yang Korea University: J.S. Kang, S.K. Park, J.H. Choi Kyungpook National University: Y.D. Oh, K.H. Han, D.H. Kim, J.S. Seo, U.C. Yang Seoul City University: I.K. Park Sungkyunkwan University: I.T. Yu, Y.P. Yu Yonsei University: B.S. Jang, S.H. Jeong, J.H. Kang, Y.J. Kwon I’d like to talk about silicon calrorimetr. Actually what I want to talk about is a sort of report on our experience on silicon production. Let me start with why si is considered and what to be considered, and I will show you our work on silicon for a space experiment. And finally a few words on remarks.

Beam test Condition Beam Test : Aug. 30 – Sep. 7 2004 SPS : 400GeV proton beam Beam interaction with a target (T2) Beam cycle length 18.0 sec. 4.8 sec spill length User controls test beam particle type, energy(10,20,30,50,80,100,150 GeV), focus, and the intensity Test beam energy accuracy +/- 0.3% Beam particle purity > 95%

Tungsten and mechanics Tungsten size : 65.5 mm X 57.5 mm ( ~ sensor size) purity : close to 99% ( Rm = 9mm) thick : 3.5 mm (= 1 X0)

Sensor and analog electronics The heritage from space experiment 1mm inactive gap between sensors Silicon Sensor 32 pixels in a layer 131mm X 115mm Analog Board Aluminum 1.5mm pcb structure 10 mm Tungsten 3.5 mm Aluminum 1.5 mm 15 mm Rt= a layer / tungsten = 15.0/3.5 = 4.8 (CALICE ~ 2) Eff. Rm = 9mm * (1 + Rt) = 52mm Total 20 layers = 20 X0, 30cm thick 19 layers of shower sampling

Assembly & Mechanic support Tungsten 1X = 35mm Rt= a layer / tungsten = 150/35 = 4.8 (CALICE ~ 2) Total 20 layers = 20X (a CALICE prototype.: 30 layers 30X)

Assembly

Beam Test Activity beam 1. Tunning time delay 2. Detector Alignment run 3. MIP calibration of all channels (no tungsten) 4. Data Run (20 layers) (electron 150,100,80 50,30,20,10 GeV hadron 150 GeV muon 150 GeV) 5. Data Run (10 layers) : to study transverse shower profile beam

Monitoring data & alignment Detector alignment Data monitor : online, offline

Data Summary (50GB) Beam Beam Energy (GeV) files Etc 4x4x20 Muon 150 23 TD Check Electron 50 33 TD Check Pion 150 35 Sensor scan 4x4x20 Tungsten Pion 150 12 Muon 150 42 Electron 150,100, 80,50, 30 ,20 ,10 399/37~89 4x8x10 Tungsten Pion 150 3 Muon 150 18 Electron 150, 100, 50, 20 162/36~48

Channel Scan for MIP calibration Channel summary noisy(~10%) ADC unstable(~5%) deal channels (~5%) One panel of sensor shown as an example

Gain Calibration of Individual Channels Pedestal : Gaussian Fit Mean : 5206.9 Sigma : 7.2 150 GeV Muon Beam Scan over All 640 Channels Size of signal from the pedestal level of a channel is used to calibrate the channel S/N (signal to noise rate) = 5.2 (5243 -5207)/7.2 Signal : Landau Fit Peak : 5243 ADC Counts

Detector Response to Different Particles First look of data Just sum of all channels Including noisy, bad and dead channels Not optimized detector No calibration No beam position information considered 50 GeV Electron 50 GeV pion 150 GeV Muon Total ADC of an event / 640

Detector Response to Electron Beam(sum of all channel) First look of data 150 GeV Electron 100 GeV Electron 80 GeV Electron 50 GeV Electron 30 GeV Electron 20 GeV Electron 10 GeV Electron Total ADC of an event / 640

Calorimeter Calibration : ADC vs. Beam Energy First look of data Very preliminary Total ADC above pedestal / 640 Fit to Straight Line -> Slope 4.2 (ADC/GeV) Electron Energy in GeV

Energy Resolution vs Energy First look of data Very preliminary dE / E (%) Electron Energy in GeV

Summary 1. Beam test of Silicon-Tungsten during Aug. 30 to Sep. 7 at CERN 2. ~50GB data collected using electron, muon and pion beam 3. Analysis is under way : noisy, unstable, dead channel. leakage due to large effective RM (52mm) not optimized electronics and detector for LC calorimeter 4. Require detailed MC study for the accurate geometry 5. Si/W Detector is working . The result will be presented in next LCWS. 6. In Korea, R&D for LC calorimeter is going on. This beam test experience will give positive idea for R&D activity.