Workflow diagram depicting the main steps in scanning with 2D and 3D/4D ultrasound. The scan is always started in 2D and the area of interest is mapped.

Slides:



Advertisements
Similar presentations
Endometrial cancer. A, B: Long-axis images of a polypoid mass surrounded by a thin sliver of intraluminal fluid. This tumor occupied the entire uterine.
Advertisements

A: Chemical shift artifact (arrows) on T1-weighted gradient echo scan in right ovarian dermoid cyst. This finding is the white on black line that occurs.
Color Doppler. Color Doppler measures the frequency shift and displays it as color over the gray scale image. Note the color scale to the left of the ultrasound.
TV-CDS of early intrauterine pregnancy
TV-CDS of early intrauterine pregnancy
This is a dual view of a fetal spine
Normal 5-week intrauterine pregnancy (IUP)
Transabdominal ultrasound image showing the appearance of water in the stomach, a technique effective to displace overlying gas in the stomach and allow.
3D and 4D ultrasound volume ultrasound can obtain image planes and provide depth far beyond the capability of 2D ultrasound. Source: VOLUME SONOGRAPHY:
This is a composite image of various 3D/4D ultrasound instruments
Complex, predominantly cystic masses
Complex, predominantly cystic masses
Recording of fetal heart rate and uterine activity
Completely cystic masses
PICC line thrombus (arrow) with 2D (A) and 3D (B) imaging.
Nine patterns of inflammatory skin disease. (See also Table 8–1.)
Endocavitary probe (a)
Forearm support for sustained work at the computer.
Diagnostic algorithm for normocytic anemia.
Miscellaneous conditions
This figure presents a dual view of a conventional 2D image and VCI-A volume contrast imaging in plane A) still TIFF image generated from a 4D video sequence.
TV-CDS of early intrauterine pregnancy
Staging of endometriosis
Solid masses. A: Transverse sonogram showing enlarged right ovary (between +'s) with echogenic areas consistent with hemorrhage due to ovarian rupture.
Solid masses. A: Transverse sonogram showing enlarged right ovary (between +'s) with echogenic areas consistent with hemorrhage due to ovarian rupture.
Complex predominantly solid masses
Characteristic appearances on imaging (a) Bone scan of tibial stress fracture (b) MRI of tibial stress fracture showing fracture line (arrows) in the presence.
TV-CDS of early intrauterine pregnancy
Composite 2D-mode image and M-mode image of a small pleural effusion
Color/power Doppler (HD-flow™, GE Healthcare, Milwaukee, WI, USA) in other renal abnormalities. A, A': In a case of horseshoe kidney, color Doppler sonography.
(Data from Rosenfeld RL. N Engl J Med 2005; 353:2578–2588.)
Amplitude versus frequency transvaginal color Doppler sonography (TV-CDS). A: Frequency-based TV-CDS shows solid mass within the left ovary without significant.
Midsagittal section through the brain of a patient with a brain stem tumor. Histologic findings showed the tumor to be an ependymoma. Source: Discussion.
From ancient times until the present day, an appreciation of the beauty of the human form in motion has always captivated the attention of artists, scientists,
Tubal obstruction (extrinsic)
(Data from Rosenfeld RL. N Engl J Med 2005; 353:2578–2588.)
This is a composite image of 2 different cases of 3D sonohysterography
Image acquisition in a modern CT scanner
Other adnexal masses and conditions
Complicated early pregnancy. A: TVS of an embryonic demise
Fibroids. A: Transabdominal sonogram (TAS) of large uterine fibroid (arrow) extending from uterine fundus. B: Transverse TAS of degenerated fibroid (arrow)
Intrauterine devices. The coronal planes of 3-dimensional sonography best depict the type and positioning of the Copper T 380A IUD (ParaGard) (A) and levonorgestrel-containing.
Major scanning planes for transabdominal sonography (TAS) and transvaginal sonography (TVS). A: Normal adult, parous uterus in long and short axis as depicted.
Sonographic images of retained products of conception shown on longitudinal (A) and transverse (B) views as echogenic material in the lower uterine segment.
Fixed flexion deformity of the hips
Sonographic images of monochorionic twins
Intrauterine devices (IUDs)
Aliasing on a Doppler waveform, a consequence of the Doppler frequency being greater than having the pulse repetition frequency. Source: Chapter 2. Instrumentation,
Normal 5-week intrauterine pregnancy (IUP)
Graphic illustration of different volume ultrasound probes, volume acquisitions, and beam characteristics. A: Free-hand acquisition where the probe is.
Twins commonly experience decreased growth after 26 to 28 weeks and, as in this set, the effect may be more pronounced on the smaller of the twins. At.
Sonohysterography (SHG) in infertility
Moderate to severe urinary tract dilation
Sonohysterography (SHG) in infertility
Normal 6- to 7-week IUP. A: Magnified TV sonogram of 3-mm embryo/yolk sac (arrow). Compare to Figure 3-1H. B: TV sonogram of 6-week IUP with 6-mm embryo.
Normal 6- to 7-week IUP. A: Magnified TV sonogram of 3-mm embryo/yolk sac (arrow). Compare to Figure 3-1H. B: TV sonogram of 6-week IUP with 6-mm embryo.
Twelve representative volumes arranged by gestational age
Multifetal pregnancy. A: TAS of normal 7-week diamniotic, dichorionic twin IUP. B: TVS of demised embryo (+'s) adjacent to living twin at 7 weeks. C: TAS.
Fibroids. A: Transabdominal sonogram (TAS) of large uterine fibroid (arrow) extending from uterine fundus. B: Transverse TAS of degenerated fibroid (arrow)
Septate ovarian cyst. A: Traditional 2D image of a septate ovarian cyst. B: Surface rendering of the inside of the cyst showing a smooth wall and a single,
Septate ovarian cyst. A: Traditional 2D image of a septate ovarian cyst. B: Surface rendering of the inside of the cyst showing a smooth wall and a single,
Renal dysplasia secondary to posterior urethral valves
Solid masses. A: Transverse sonogram showing enlarged right ovary (between +'s) with echogenic areas consistent with hemorrhage due to ovarian rupture.
Fetal endoscopic tracheal occlusion (FETO) for severe congenital diaphragmatic hernia. (Used with permission from Dr. Rodrigo Ruano, Texas Children’s Hospital,
Open maternal-fetal repair for fetal myelomenigocele
Ectopic pregnancy: uterine sonographic findings
This is a first trimester scan in a fetus with monosomy X
Copyright © The McGraw-Hill Companies, Inc
Chapter 3 Image Slides Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
Copyright © The McGraw-Hill Companies, Inc
Presentation transcript:

Workflow diagram depicting the main steps in scanning with 2D and 3D/4D ultrasound. The scan is always started in 2D and the area of interest is mapped out in 2D. The suitability of the volume acquisition plane is assessed in real time conventional 2D first. The volume is acquired and by default displayed in a user selected or manufacturer default display mode. A quick exploration of the acquired data will ensure the intended image planes are indeed included in the volume and no artifacts are present. Depending on the clinical need, either a qualitative or quantitative analysis will be done, including at times creation of short video sequence. If the processed data are deemed informative and useful for comparison in follow up scans, they are initially saved in the hard drive of the machine, and eventually later transferred to a longer storage option such as a server or DVD disks. Source: VOLUME SONOGRAPHY: CORE CONCEPTS FOR CLINICAL PRACTICE, Sonography in Obstetrics and Gynecology: Principles & Practice, 7e Citation: Fleischer AC, Toy EC, Lee W, Manning FA, Romero RJ. Sonography in Obstetrics and Gynecology: Principles & Practice, 7e; 2014 Available at: https://obgyn.mhmedical.com/DownloadImage.aspx?image=/data/books/1414/fle_ch43_f001.png&sec=76397124&BookID=1414&ChapterSecID=76397115&imagename= Accessed: October 11, 2017 Copyright © 2017 McGraw-Hill Education. All rights reserved