Garrett Plumstead Nick Pantelakis Eston slacks

Slides:



Advertisements
Similar presentations
Code Analysis:Accessibility Colleen MacEachern & Stephanie Novak.
Advertisements

Alveo Standard Finish.
Chapter 5 Measuring Carpentry Work. Board Measure Most lumber is dressed; this means that surfaces are sanded, which reduces the size of cross section.
ADA Enhanced Condo Client: Kelly Heller Blind 48 years of age Sculptor
CURRENT ADA AND ICC COMPLIANCE DATA AN INTRODUCTION TO BOBRICK’S ADA- COMPLIANT PRODUCTS, AS WELL AS BASIC MOUNTING HEIGHTS AND REACH RANGES DOWNLOAD THE.
DEPARTMENT OF DEVELOPMENT SERVICES BUILDING DIVISION Ronald L. Lynn, Director/Building Official Gregory J. Franklin, Assistant Director Neil Burning, Manager.
TORONTO, CANADA BY: KATIE BROWN Toilet and Bath Scavenger Hunt.
Interior Designers of Canada
Room Planning and Sleeping Area
© Goodheart-Willcox Co., Inc. Permission granted to reproduce for educational use only 1 PowerPoint Presentation Publisher The Goodheart-Willcox Co., Inc.
Sleeping Area and Bath Facilities
Accessibility.  A building code is a set of rules that specify the minimum acceptable level of safety for buildings. The main purpose of building codes.
EDT Floor Plan Design-Bathrooms1 Weekend Cabin Retreat Project Designing the Floor Plan - Bathrooms Sacramento City College EDT 300.
 Determine the waterline components needed to complete the water supply for the bathroom shown in figures 13-6 and 13-7.
1. Today’s Agenda Chapter 3: Building Blocks Chapter 4: Accessible Routes Chapter 5: General Site and Building Elements Chapter 6: Plumbing Elements and.
Kitchen and Bath History. S The First Electric Range 1910.
BATHS. Function The bath must be planned to be functional, attractive, and easily maintained. May also contain dressing, laundering, exercising, and sunning.
Visitability Standards Dan McNabb, Deputy Building Official Planning and Development Review Department.
AT 201 Introduction to Architecture
2004 Florida Accessibility Code for Building Construction
Source of Specifications:
Sleeping areas: bedrooms, bathrooms, dressing rooms, and nurseries.
7.02 Bathrooms.
Bathrooms SHI 7.02 Explain the essentials of home baths.
BATHROOMS Objective Bell Ringer 11/4  Work with your table groups to brainstorm and make a list of at least 10 technological “gadgets” used in.
INTD 59 intro to kitchen & bath design bathroom finishes & accessories.
PERFORMANCE & CODE ANALYSIS TIMBer Inc. ·Brooke Fedder · Marie Rottschaeffer· Izzie Molinuevo· Tena Pettit·
The ADA National Network Great Plains ADA Center www.adaproject.org 2010 Standards for Accessible Design – Part II Chapters 6-9 Presented.
Americans with Disabilities Act Compliance Inspections Prepared for: Washington State Transit Insurance Pool December 8, 2010 Michael Miller Certified.
Room Relationships and Sizes
Room Relationships and Sizes
Chapter 12 Sleeping Areas Types of Sleeping Areas Bedrooms Average size – 100 to 200 square feet 3 items must accommodate a minimum size bedroom –Single.
Fair Housing in Focus Accessibility. Accessibility Properties fall under several different laws. Federal programs and the age of the property determine.
Difference between 2003 and 2009 ICC/ANSI A117.1 applicable to the Plumbing Subcode Presented by: John N. Terry Tom Pitcherello.
Objective 1.03: Explain ways to adapt housing to meet special needs.
Objective 7.02: EXPLAIN the essentials of home baths.
ACCESSIBLE BATHROOMS. GENERAL CRITERIA Use low flow, EPA's Watersense Program toilets Sensor control faucets to save water Lever handles on doors and.
ID 440: Project 1: Hospitality Design
Objective 1.03: Explain ways to adapt housing to meet special needs.
UNIVERSAL DESIGN- BARRIER FREE ENVIRONMENTS
BUILDING CODES AND ADA/TAS. BUILDING CODES - EGRESS.
By Angela Forte, Michelle Gagnon, Kerri Morse, & Sam Oosterman.
Objective 1.03: Explain ways to adapt housing to meet special needs.
(ACCESSIBILITY LAW) MINIMUM REQUIREMENTS FOR ACCESSIBILITY
Codes and costing construction + materials II. Building Code (780 CMR) Building Code (780 CMR) Accessibility Code (521 CMR) Accessibility Code (521 CMR)
 Where the family sleeps, rests, and bathes  Takes up about 1/3 of the house  Should be in the quietest part of the house  Should be on the south.
Hogan Residence Basement Bath Addition Valued Repeat Customer Kitchen Remodel (see other presentation) Basement Bathroom Addition Upstairs Bathroom Remodel.
Toilet design Many different regulations 1. guess what toilet features might be regulated? building code? accessibility code? universal design?
Toilet design Many different regulations 1. can you guess what might be regulated? building code? accessibility code? universal design?
Americans with Disabilities Act (ADA) Standards (Title II & III)
Kitchens, Laundry Areas and Baths Chapter 22. Objectives 1. Explain basic principles for designing efficient kitchens, laundry areas and bathrooms. 2.
“My Room” Project The Massachusetts Code Book and the rules that apply.
BEDROOMS & BATHROOMS- PRIVATE ZONES. BEDROOMS- REQUIREMENTS: All Sleeping Areas should be near: Each-other (Bedrooms all near each-other OR master in.
Bathrooms. Half-Baths AKA Powder Rooms Contains only a sink and a toilet. Where are ½ baths usually located?
7.02 Bathrooms. Types of Baths _________________/powder room - sink & toilet only _________ bath - sink, toilet, ______________/shower ________ bath –
8 Planning the Sleeping Area Chapter. Permission granted to reproduce for educational use only.© Goodheart-Willcox Co., Inc. Objectives Discuss factors.
House Project.
7.02 Bathrooms.
3 AREAS of RESIDENCE Sleeping-family sleeps, rests, and baths
PowerPoint Presentation
Planning for the Quiet/Private Areas of a Home
Sleeping Area and Bath Facilities
Objective 7.02: EXPLAIN the essentials of home baths
Dorm Room Activity Design a dorm room that is no larger than 180 square feet (12X15) Your room must include the door, a window, and the closet. Use ¼ inch.
Hannah Ehresman, Kelsey Russell, Kaitlyn Higgins, Lynette Akai
BUILT ENVIRONMENT ACCESS AUDITS
Bathrooms Interior Design I Objective 3.03.
Building standards Mr. Da Silva.
Objective 7.02: EXPLAIN the essentials of home baths
Bathrooms Note: This PPT does not contain images, please insert your own or download the Bathrooms PPT from the FI51 Teacher Shared Resources Folder on.
Presentation transcript:

Garrett Plumstead Nick Pantelakis Eston slacks Bathrooms codes Garrett Plumstead Nick Pantelakis Eston slacks

Information GENERAL Code number F213 must comply where bathroom facilities and toilet facilities are provided. 603.2.2 Overlap. Required clear floor spaces, clearance at fixtures, and turning space shall be permitted.

TOILET AND BATHING ROOMS F213.2.1 Unisex (Single-Use or Family) Toilet and Bathing Rooms. Unisex toilet rooms shall contain not more than one lavatory, and two water closets without urinals or one water closet and one urinal. Unisex bathing rooms shall contain one shower or one shower and one bathtub, one lavatory, and one water closet. Doors to unisex toilet rooms and unisex bathing rooms shall have privacy latches.

Plumbing fixtures and accessories F213.3.6 Bathing Facilities. Where bathtubs or showers are provided, at least one bathtub complying with 607 or at least one shower complying with 608 shall be provided. F216.8 Toilet Rooms and Bathing Rooms. Where existing toilet rooms or bathing rooms do not comply with 603, directional signs indicating the location of the nearest toilet room or bathing room complying with 603 within the facility shall be provided. 603.3 Mirrors. Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches (1015 mm) maximum above the finish floor or ground. Mirrors not located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 35 inches (890 mm) maximum above the finish floor or ground.

Clearances 604.3.2 Overlap. The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear floor space and clearances required at other fixtures, and the turning space. No other fixtures or obstructions shall be located within the required water closet clearance.

Questions