Zelio Logic - Communication Extension

Slides:



Advertisements
Similar presentations
Innovative Switching & Control
Advertisements

Supervisory Control & Data Acquisition DAQ Networking.
Arctic IEC-104 Gateway Jari Lahti, CTO.
Orion Telecom Networks Inc Slide 1 STM-1 63 E1 (Optical / Electrical) SDH Add-Drop Multiplexer Updated: Dec, 2010Orion Telecom Networks Inc
TCP-IP Primer David Cozens. Targets Have a basic understanding of Ethernet network technology Be aware of how this technology is applied on the 5000 series.
Niobrara R&D Corp Compact PLC Upgrades With the CERI.
ATiM Spécialiste en étude et développement de produits de radiocommunication
Introduction System Schematic ~ LON-FO NC EC200 LOOPS 2-4 FIBRE OPTIC
EUT 1040 Lecture 10: Programmable Logic Controllers.
Eycon Visual Supervisor
90-70 DeviceNet configuration
Microprogrammes control the KOMBIS TMM8003. For the reliable operation of its systems and devices there are several programs located in two controllers.
Slide 1 / 35 P&T - GPS - Training PhB - 01_TECH_TeSys_U_controller_ en 06/2004 Presentation of the range Composition of the controller  Control base 
1 Introduction to Jan. 20, 2011 Vio Fan ICP DAS Co., Ltd. tDS-700 Series tGW-700 Series.
1  Module Type Overview  Construction  Characteristics  Installation principles  Details PD 600-Series.
ZIGBEE Network Introduction Integrated with Zigbee or Bluetooth products Operation voltage : DC 7V ~ 40V. RS232 Interface Meets or Exceeds TIA/EIA-232-F.
Slide 1 / 20 Industrial Automation - Custumer View - Services PhW - Modbus_en 06/ 2002 Modbus training.
MIG II DIGITAL FEEDER PROTECTION
eAutomation Enabler – Advantech Industrial NETworking
Orion Telecom Networks Inc Slide 1 4 x Ethernet over E1(4*FE1) Updated: April 2010Orion Telecom Networks Inc Ethernet over E1 (4xFE1)
0 RS-485 MODBUS COMM. D. Digital Trip Relay 6. IO (Input-Output) Port Profibus -DP COMM. Digital Trip Relay - P and S type are equipped with RS- 485 communication.
Serial Expansion Hardware
Lexmark Wireless Printer Adaptor Instructions Step 1. For a Mac, go to network preferences/ select built-in-ethernet and click on TCP/IP tab and annotate.
Application Protocol for Veris E30 Panel-board Monitoring System Jaein Jeong UC Berkeley LoCal Workshop Oct 5 th, 2009.
1 Product & Technology Quality Excellence Support American Global Products Product & Technology TeSysPort Ethernet Interface for TeSys June 5, 2007.
M340 Modbus Plus Proxy Link legacy systems to Ethernet
Orion Telecom Networks Inc Slide 1 Ethernet over E1(FE1) Updated: April 2010Orion Telecom Networks Inc Ethernet over E1 (FE1) Product Presentation.
ZELIO2 COM: TECHNICAL PRESENTATION
Section 6 - Slide 1 / 27 P&T - GPS - Training PhW - 06_TECH_Modbus_en 06/ 2004 Modbus training Part 1 :Reference documents - WEB sites Part 2 :Definitions.
GPRS functionality overview in Horner OCS. GPRS functionality – Peer to Peer communication over GPRS – CSCAPE connectivity over GPRS – Data exchange using.
New product introduction:
Do-more Technical Training
Lecture 10: Programmable Logic Controllers
CMV-NET Chigo VRF Network Centralized Control System
Frequently Asked Questions (FAQ)
VARLOGIC NRC12 Varmetric Controller
ISaGRAF Embedded Controller : I-84x7 / I-88x7 : User’s Manual
BRX Technical Training
Industrial 1-port RS422/485 Modbus Gateway
Do-more Technical Training
SMS module HDL-MGSM.431.
195E Serial Interface SECTION 9 - Serial Interface.
Site Controller Unit and Trunk Interface Unit
UNICOS: UNified Industrial COntrol System CPC (Continuous Process Control) Basic course SESSION 3: PLC basics UCPC 6 UNICOS-Continuous Process Control.
Modbus RTU CP1L with V1000 and Celciux.
Haiwell PLC Modules Introduce
Do-more Technical Training
Freelance 2000 ABB Automation ABB-1408 Page 1.
DT80 range Modbus capability
90-30 DeviceNet configuration
Crouzet touch Quick start.
SIO-RTD RTD MODULE.
A SEMINAR ON INDUSTRIAL NETWORKING STANDARDS FOR IMPROVED COMMUNICATION AND CONTROL PRESENTED BY MARK MARVELLOUS .P (COE OPTION)
Network Peripheral.
EILERSEN The Weighing experts.
HMI CP Range General Presentation.
Valiant Communications Limited
SCADA Communication and Architecture Principles
PLC’s Are ... Similar to a Microcontroller: Microprocessor Based
Always Connected introduces Tigo SMART 3.1 This guide is interactive!
GMA Gas detection system
Ethernet Gateway EGX200 - EGX400
Total HVAC Control from anywhere Easy control that can save a fortune
Switching & Controlling LoB
Integrated gateway-server
Network Addressing.
EUT 1040 Lecture 10: Programmable Logic Controllers Unrestricted.
energy revenue & power quality meter
Field installable, upgradeable and scaleable
How to install a WISE-4051 Device Presented By: Mark Brown
Presentation transcript:

Zelio Logic - Communication Extension D Ethernet extension set up C Ethernet extension presentation B Modbus extension set up A Modbus extension presentation

Modbus extension Presentation Ethernet extension set up C Ethernet extension presentation B Modbus extension set up A Modbus extension presentation Modbus extension presentation Modbus extension presentation

In bold => factory setting Characteristics Zelio logic connected on modbus via the Modbus extension module With modular Zelio Logic power supply 24 VDC Modbus slave not electrically isolated, RTU/ASCII protocol Configuration : Zelio HMI or Zelio- Soft Number of wires = 2, 4 Frames format = RTU or ASCII Speed = 1200, 2400,…,19200,…,57600 Parity = none, even, odd Address = 1 to 247 + SR3 B...BD SR3 MBU01BD In bold => factory setting

Modbus requests supported Characteristics Modbus requests supported Read multiple registers : Modbus function code = 03 (0x03) Write simple register Modbus function code = 06 (0x06) Write multiple registers Modbus function code = 16 (0x10) Read device identification Modbus function code = 43 (0x2B) The broadcast mode is supported (writing to address 0). To get more information concerning the Modbus protocol, see the Web site Modbus.org http://modbus.org

Description Front panel 1 1 Mounting : on rail 35mm, retractable mounting feet, 2 Connector RJ45 : Modbus fieldbus connection 3 DEL « COM » : communication status 4 DEL « PWR » : Product powered or in fault 5 Screw for connection to the protection ground 3 2 4 5 SR3 MBU01BD

Connection example Connection with T junction Twido (modbus master) 1 1 Twido compact+Port COM RS485 miniDIN 2 Zelio logic and extension modbus 3 Line end of 120 ohms 4 T junction : VW3A8306R 5 Cable 3m mini-DIN and RJ45 : TWDXCARJ030 6 Cable with 2 RJ45 connectors: VW3A306R.. 3 4 4 4 3 5 5 5 2 6 2 6 2 6 31 modbus slaves maximum

Modbus extension set up Ethernet extension set up C Ethernet extension presentation B Modbus extension set up Modbus extension set up A Modbus extension presentation

Configuration Using of Zelio HMI Using of Zelio-Soft From the main menu : Select the “ CONFIGURATION ” and select “ INIT.MODBUS ” to access to modbus parameters. From the edition menu : Click on program configuration and click on tab “ MODBUS extension ” to access to modbus parameters.

Ladder language - LADDER Modbus exchanges Modbus exchanges are implicit and transparent for Zelio. The Zelio application data are not accessible by the master.

Function Block Diagram - FBD 2 exchanges types Implicit exchanges with the master Modbus. Input/Output datas between the Zelio application and the master Modbus Implicit exchanges with the master Remark : In FBD mode, the state of Zelio I/O are not accessible with implicit exchanges.

Function Block Diagram - FBD Inputs/Outputs data words exchange between Application Zelio / Master 4 inputs words : J1XT1 to J4XT1 4 outputs words : O1XT1 to O4XT1

Function Block Diagram - FBD Inputs/Outputs data words exchange between Application Zelio / Master Screen of FBD Editor OUTPUT 4 words O1XT1to O4XT1 accessible in reading by the master 4 words J1XT1 to J4XT1 accessible in reading/writing by the master INPUT

Application example The application Zelio check the temperature. The controller Twido transmit the temperature set point (threshold) to Zelio via the fieldbus modbus. The measure of temperature is wiring on the Zelio analogue input. If the temperature is higher than the threshold, an alarm is activate (Klaxon). Twido (master) Twido (master) manages the Modbus exchanges which are transparent for Zelio Logic. Temperature set point modbus Temperature measure Zelio (slave)

Application example Using the input word J1XT1 to write the temperature set point and the output word O1XT1 to read the measure. Reading of the measure in the output word O1XT1 by the modbus master Writing of the set point in the input word J1XT1 by the modbus master

Ethernet extension presentation D Ethernet extension set up C Ethernet extension presentation Ethernet extension presentation Ethernet extension presentation B Modbus extension set up A Modbus extension presentation

Characteristics Zelio logic on Ethernet via the Ethernet extension module Compatible Zelio Logic modular 24 VDC Connecteur RJ45 10/100 T Modbus TCP/IP server Adresse IP : acquisition static or dynamic Configuration : Zelio Soft 2, FBD language + SR3 B...BD SR3 NET01BD

Characteristics Modbus TCP/IP request supported Reading of n register Function code = 03 (0x03) Writing of simple registers Function code = 06 (0x06) Writing of n registers Function code code = 16 (0x10) Reading device identification Function code code = 43 (0x2B)

Module IP Address (setting factory) : Description Front panel 1 1 Monting : Rail 35mm, patte de fixation 2 RJ45 connector : Connexion on Modbus TCP/IP 3 Bicolor LED “LK/ACT” : Display speed COM 10/100 4 LED “STS” : Communication status Ethernet 5 Screw terminal : Ground 3 2 4 6 6 On the right side of the device: MAC Address (single for each device) 5 SR3 NET01BD Module IP Address (setting factory) : 85 . 16 . X . Y (decimal code) (X = Value of the last byte before of the MAC Address ; Y = Value of the last byte of the MAC Address)

Twido Compact (client) Ethernet Architecture Connection example Twido Compact (client) 1 Zelio Logic (server) 4 5 1 Twido compact : TWDLCAE40DRF 2 Ethernet cable RJ45 connector : 490 NTW000 .. 3 Switch conneXium 499 NES251 00 4 Zelio logic modular : SR3B…BD 5 Ethernet extension module : SR3NET01BD 2 3 2 2 Zelio Logic (server)

Ethernet extension set up D Ethernet extension set up Ethernet extension set up C Ethernet extension presentation B Modbus extension set up A Modbus extension presentation

Ethernet extension configuration - Zelio Soft 2 Menu edition : Select “Program configuration” Menu Program configuration : Click on tab Ethernet extension 1 2 FBD Language

Ethernet extension configuration - Zelio Soft 2 In the IP Address field : Click on dynamic Address if the network have a bootp server Otherwise click on Static Address and enter IP Address, Sub-network mask (here Class C network), and Gateway address 3 If the Ethernet extension must be constantly connected to a client, enter the client address in the reserved Address field 4 Modification of the Time-out : time after which the Ethernet extension must close an inactive connection 5 The Ethernet extension manage until 4 connections in simultaneous.

Data Exchanges with the Modbus client Data words accessibles via application Zelio 4 Input words : J1XT1 to J4XT1 4 Output words : O1XT1 to O4XT1

Data Exchanges with the Modbus client Status and Clock of Zelio Logic

Application Example FBD editor screen : Data accessibles by the Client 4 words O1XT1to O4XT1 accessible in reading by the client OUTPUT 4 words J1XT1 to J4XT1 accessible in writing/reading by the client INPUT