PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 1 HighPROTEC-2 MRI4-2 Feeder Relay Sales presentation 2015/08/10.

Slides:



Advertisements
Similar presentations
Variable Frequency Drives Bypass Options
Advertisements

سیستم آلارم دیجیتالی مجهز به ثبات خطا
GENERATOR SIMULATOR FOR EXCITATION SYSTEM TESTING
Square D Electrical Protection And Monitoring
Model H Free Standing Static Transfer Switch. Why choose a model H static transfer switch? Increases power availability. True solid state. Rugged, reliable.
VAMP 300 IED functionality Feeder relay Motor relay
GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel.
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
Multi Functional Digital Fault Recorder
MIFII DIGITAL FEEDER PROTECTION A Cost Effective Protection Solution for Overcurrent Protection at Any Voltage Level GE Multilin
AC Inverter Drives 500 Series Product Range Overview 2000 AC Inverter Drives.
Eaton Air Circuit Breakers Arc Flash Reduction Maintenance System
Protections from the technical point of view “What you always wanted to know about protections and were afraid to ask…” Petra Píclová Online training
EVD4 - The Smart eVolution Primary distribution circuit-breaker with integrated protection, control and sensors © ABB Group 15. April 2017 | Slide 1 1.
SYMAP-BC SYMAP-BC.
Eycon Visual Supervisor
Presents The Silver Family An Integrated Approach to Processors, Data Communication and Head End Integration.
Slide 1 / 35 P&T - GPS - Training PhB - 01_TECH_TeSys_U_controller_ en 06/2004 Presentation of the range Composition of the controller  Control base 
AS-i, The Simplest Automation Networking Solution Dated: 10/30/2008.
G3 Electronics Platform Overview Presentation. G3 Electronics Platform Pneumatic Valve Side 32 Solenoid Output Capability Including Valve side Sub-D.
Palletizing the Easy Way
1 PCA2 On-load Protection Condition Analyser. 2 PCA2 online testing concept Concept introduction: PCA2 is a new system test approach intended to save.
Control and Status of Simulated Breakers Using HMI
Moeller GmbH BU Circuit Breaker Protective note to rule DIN ISO is to be considered The new line of circuit breaker IZM ILS-P / W. Wagner Aug 03,
 Wireless, Web-Based Monitoring System  Alarm/Event Notifications by Text Message and or  VPN Connection for Fast Response to Alarms and Events.
Industrial Systems Introducing the L90 Universal Relay Advanced transmission line protection and control High-speed current differential protection for.
Integrating S into your Product Lifecycle
MIG II DIGITAL FEEDER PROTECTION
Advantys ETB Ethernet IP67 I/O
SUBSTATION MODELING: PROTECTION AND AUTOMATION
1 Industrial Systems A dvanced L ine P rotection S ystem.
Workflow Based Tools Simplifying All Job Functions.
Motor Control Center MNS iS with Condition Monitoring
G650 Generator Protection & Control System
1 © Red Lion Controls Inc. Introducing the RAM 9000.
Scheduled Versus Event Driven Testing of Distribution Protection IEDs Dr. Alexander Apostolov, Benton Vandiver, Will Knapek, OMICRON electronics.
Page 1 ADAM-6000 Web-enabled Smart I/O Γιάννης Στάβαρης Technical Manager Ιούνιος 26, 2007.
Single Loop Analogue addressable fire control Panel
Electrical Distribution Training
1.Overview 2. Hardware 3. Software Interface 4. Triggering 5. Installation 6. Configuring.
1 Product & Technology Quality Excellence Support American Global Products Product & Technology TeSysPort Ethernet Interface for TeSys June 5, 2007.
Medium Voltage products Energy reliability & revenue improvement Speaker: Jean-Yves Pocthier - Schneider Electric France Technical solution for improvement.
Electrical Distribution Training
Current operation (black keys) Descriptions Parameter / protection setting (blue keys) Main points to remember A B C D ? SEPAM UMIs SEPAM UMI OPERATION.
Modular Inverter.
Product range/ALPHA-E-0001-tri-20/04/03 ALPHA Micro Controllers A single multi-functional unit instead of multiple components ALPHA / ALPHA XL Products/ALPHA.
AQ 100 Series Arc Flash Protection System. Characteristics of arc protection Speed, no intentional delays Sensitive, current set-points just above loads.
3-Phase Submersible Motor Control
PowerIT Air Insulated Cubicle Uniswitch
YASKAWA VS-606 V7 COMPACT VECTOR - CONTROLLED INVERTER FOR GENERAL USE 230V (Single-Phase).1Kw ~ 3.7Kw (.13HP ~ 5HP) 230V (Three-Phase).1Kw ~ 7.5Kw (.13HP.
SmartMQn Motor Horner APG, LLC September 9, 2008.
New product introduction:
1 Industrial Systems BUS2000 Busbar Differential Protection System Differential overcurrent system with percentage restraint protection.
Survey of Smart Grid concepts and demonstrations Smart substation Ari Nikander.
ACT20X Ex isolator/ amplifier. Page 2 ACT20X (Ex isolators family) Overview - Connects to process equipment in Class/Div, or Zone 0 - Zone 2 areas - ACT20X.
ARM and GPS Based Transformer monitoring system with area Identification Student Name USN NO Guide Name H.O.D Name Name Of The College & Dept.
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
FLATPACK Rev.5 September 2002 Updated versions may be available.
HighPROTEC-2 MRA4-2 Directional Feeder Relay Sales presentation
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 1 HighPROTEC-2 “Electrical Protection Made Simple” Sales Presentation.
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 1 HighPROTEC-2 New features with Rel 3.0 Sales presentation 2015/08/03.
HighPROTEC-2 MRMV4-2 Motor protection relay with voltage measurement Sales presentation 2015/08/10.
HighPROTEC-2 MRM4-2 Motor Protection Relay Sales presentation
HighPROTEC-2 “Electrical Protection Made Simple” Sales Presentation
HighPROTEC-2 MCDTV4-2 Transformer Protection with differential Sales presentation 2015/08/10.
HighPROTEC-2 MCA4-2 Directional Feeder Relay Sales presentation
Programmable Logic Controllers (PLCs) An Overview.
Peter Erning, PSP-T11, Power Gen 2010
HighPROTEC-2 MRDT4-2 Transformer Protection with differential Sales presentation 2015/08/10.
Presentation transcript:

PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 1 HighPROTEC-2 MRI4-2 Feeder Relay Sales presentation 2015/08/10

PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. MRI4 - Key Benefits PAGE 2  Cost savings for field service equipment and commissioning effort  Integrated Fault simulation - Faults can be simulated in the device for “dry testing” without external wiring  Easy relay configuration achieves high service staff acceptance and minimizes training expenses  Change tracking and plausibility check avoids parameter errors  Optimized overview by hidden protection modules in planning module  Text explanation for all parameter avoids misunderstanding  All in one protection functions by an optimized overview reduced risk of changed customer requirements and to order a wrong devices type  Full Protection package for OC and EC protection, recloser, NPS, Overload….  With logic, up to 80 equations

PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. MRI4 - Key Benefits PAGE 3  Production and maintenance flexibility  Flexible hardware covers a wide range of nominal values (Vn setting for DI, wide range power supply, 1A/5A in one version)  Easy wiring at the rear side, pre wiring possible via terminal kit  All terminals are removable, including current measuring terminals  PC Tool Smart View for free  Page editor to create own pages and single lines  Easy connection between PC and Protection device via USB interface  Visualization of tripping curves graphically to get visual feedback of settings and protection concept  Look and feel over the complete HighPROTEC line -reduced training efforts

PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. Product Ordering code - Easy to select  Basic description of Product  Feeder protection with logic and control for 1 switchgear / breaker PAGE 4

PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. Meets Global Standards – for the global market PAGE 5 Lloyds Register in preparation

PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. Product Features - All in One  Protection functions, one package PAGE 6

PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. Product Features - All in One  Control, Logic and Supervision functions - one package PAGE 7

PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. Product Features - All in One  ANSI functional overview - one package PAGE 8

PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. Product Features – Flexible Hardware PAGE 9  Rear side X1 Power supply and digital inputs X2 5 Relay outputs, 1 System Ok output X3 CT measuring board X100 Ethernet Interface RJ45, (IEC, Modbus, Profibus, DNP3) X101 IRIG-B interface X103 Communication Interface (IEC, Modbus, Profibus, DNP3)  Design advantages  Making it easier to apply worldwide  The flexible hardware minimized commissioning, and ordering failures  Wide range power supply VDC / VAC  Nominal voltages for the digital inputs are per software settable  CT measurement always with 1A and 5A  All terminal blocks are removable, CT Connector with integrated short circuit device  Housing based on aluminum extrusion parts

PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. Market overview PAGE 10  Protection in medium voltage distribution and generator applications  Applications in different market areas:  Power plants  Infrastructure  Main distribution stations  Commercial buildings  Distribution substations  Industry like Heavy or Process industry  Chemical industry

PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. Application Example MRI4 PAGE 11  Left side, outgoing feeder  Right side, transformer protection (small MV transformers, ~500kVA)

PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. Application - Control for 1 Switchgear/ breakers, design your own page PAGE 12  Control function up to 1 switchgears  Extended interlocking management  Switchgear timing management  Switchgear status (display Single Line)  PC Tool – Page editor  Page editor, easy to design a single line or measuring page

PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. Application Logic – Highest Flexibility PAGE 13  Provides logic editor  Up to 80 equitation's  Select the gate type  Assignment of 4 logic input gates  Output gates with/ without timer  Latched, Set  Reset, Inverter

PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. Commissioning and Maintenance PAGE 14  Fault simulation with the integrated I generator without additional wiring  Force and disarm relays, simulate temperatures…  Benefit: Save your Time and Money

PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. Disturbance analyzing PAGE 15  Event recorder  Up to 300 events with ms time stamp  Trend recorder up to 1h  Fault recorder for first analyzing  Disturbance recorder  32 samples per cycle  Up to 10s per record  Non volatile, 120s memory  Each status event, static or changes, is part of the record  Analyze your faults with low efforts

PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. Product support statement HighPROTEC  Pricing for HighPROTEC-2 Release 3.0 will be unchanged to the actual pricing  Available for sales 01 st of October 2015 Could be ordered now from today  The HighPROTEC devices Release 2.x (with blue front plate) Will get no functional update List price increase for Basic Products (not options) +20% Available for sales next two years Repair and support time minimum 7 years (1 of Oct.) PAGE 16

PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. Any questions, remarks? Thanks for your attention PAGE 17