Presentation is loading. Please wait.

Presentation is loading. Please wait.

HighPROTEC-2 MCA4-2 Directional Feeder Relay Sales presentation

Similar presentations


Presentation on theme: "HighPROTEC-2 MCA4-2 Directional Feeder Relay Sales presentation"— Presentation transcript:

1 HighPROTEC-2 MCA4-2 Directional Feeder Relay Sales presentation
2015/08/10

2 MCA4 - Key Benefits Cost savings for field service equipment and commissioning effort Integrated Fault simulation - Faults can be simulated in the device for “dry testing” without external wiring Easy relay configuration achieves high service staff acceptance and minimizes training expenses Change tracking and plausibility check avoids parameter errors Optimized overview by hidden protection modules in planning module Text explanation for all parameter avoids misunderstanding All in one protection functions by an optimized overview reduced risk of changed customer requirements and to order a wrong devices type Full Protection package for dir. OC, EC, Recloser, Power supervision, voltage, frequency… Grid coupling and stabilization functions – Intelligent frequency load shedding for GRID stabilization, Q->U protection, LVRT With logic, up to 80 equations

3 MCA4 - Key Benefits Production and maintenance flexibility
Flexible hardware covers a wide range of nominal values (Vn setting for DI, wide range power supply, wide range voltage measuring, 1A/5A in one version) Easy wiring at the rear side, pre wiring possible via terminal kit All terminals are removable, including current measuring terminals PC Tool Smart View for free Page editor to create own pages and single lines Easy connection between PC and Protection device via USB interface Visualization of tripping curves graphically to get visual feedback of settings and protection concept Look and feel over the complete HighPROTEC line -reduced training efforts

4 Product Ordering code - Easy to select
Basic description of Product Directional feeder protection with logic and control up to 6 switchgears 7 breakers

5 Meets Global Standards – for the global market
Lloyds Register in preparation

6 Product Features - All in One
Protection functions, one package

7 Product Features - All in One
Protection functions, Control and Logic - one package

8 Product Features - All in One
Supervision functions - one package

9 Product Features - All in One
ANSI functional overview - one package

10 Product Features – Flexible Hardware
Rear side X Power supply and digital inputs X Relay outputs X CT measuring board X VT measuring board X5 / X6 MCA4A = not used MCA4D = add. 6 binary outputs and 8 digital inputs X Ethernet Interface RJ45, (IEC, Modbus, Profibus, DNP3) X Communication Interface (IEC, Modbus, Profibus, DNP3) X IRIG/ Watchdog Design advantages Making it easier to apply worldwide The flexible hardware minimized commissioning, and ordering failures Wide range power supply VDC / VAC Nominal voltages for the digital inputs are per software settable VT measurement from 0V up to 800 V AC CT measurement always with 1A and 5A All terminal blocks are removable, CT Connector with integrated short circuit device Housing based on aluminum extrusion parts

11 Market overview Protection in medium voltage distribution and generator applications Applications in different market areas: Power plants Infrastructure Main distribution stations Commercial buildings Distribution substations Industry like Heavy or Process industry Chemical industry Power generation – Protection of Generators Grid Coupling of DER

12 Application Example MCA4
Example generation plant with outgoing feeder to different customers and grid coupling to the upper MV distribution network Usable for incoming, outgoing feeders, bus coupling (synch check), directional feeder applications and at the grid connecting point

13 Application Control up to 6 Switchgears / breakers, design your own page
Control function up to 6 switchgears Extended interlocking management Switchgear timing management Switchgear status (display Single Line) PC Tool – Page editor Page editor, easy to design a single line or measuring page

14 Application Logic – Highest Flexibility
Provides logic editor Up to 80 equitation's Select the gate type Assignment of 4 logic input gates Output gates with/ without timer Latched, Set Reset, Inverter

15 Commissioning and Maintenance
Fault simulation with the integrated V-I generator without additional wiring Force and disarm relays, simulate temperatures… Benefit: Save your Time and Money

16 Disturbance analyzing
Event recorder Up to 300 events with ms time stamp Trend recorder up to 1h Fault recorder for first analyzing Disturbance recorder 32 samples per cycle Up to 10s per record Non volatile, 120s memory Each status event, static or changes, is part of the record Analyze your faults with low efforts

17 Product support statement HighPROTEC
Pricing for HighPROTEC-2 Release 3.0 will be unchanged to the actual pricing Available for sales 01st of October 2015 Could be ordered now from today The HighPROTEC devices Release 2.x (with blue front plate) Will get no functional update List price increase for Basic Products (not options) +20% Available for sales next two years Repair and support time minimum 7 years (1 of Oct.)

18 Any questions, remarks? Thanks for your attention