AC890PX High Power Inverter. The history of SSD LINK 1989-1996 LINK 1 was the first fiber optic peer-to-peer network of its kind. Its sole purpose was.

Slides:



Advertisements
Similar presentations
PV String Monitoring Solution
Advertisements

…performance audio networks. ABOUT RockNet => RockNet provides ultra low latency and very high audio quality. Genuine Audio Technology  RockNet is a.
Supervisory Control & Data Acquisition DAQ Networking.
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
Niobrara R&D Corp Compact PLC Upgrades With the CERI.
IDEC AUSTRALIA PTY LTD, UNIT 17, 104 FERNTREE GULLY RD, OAKLEIGH, VIC 3166 High Performance, Compact and Economical.
MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title.
Eycon Visual Supervisor
Presents The Silver Family An Integrated Approach to Processors, Data Communication and Head End Integration.
ADAM-4572 Ethernet To Modbus Solution Ethernet to Modbus Data Gateway
Applying Wireless in Legacy Systems
PROGRAMMABLE LOGIC CONTROLLERS PLC’S
AS-i, The Simplest Automation Networking Solution Dated: 10/30/2008.
 A system consisting of a number of remote terminal units (or RTUs) collecting field data connected back to a master station via a communications system.
MUST HAVE SHOULD HAVE COULD HAVE Module # 010. Qi Hardware Objectives Recognize hardware Know how to interface to field equipment Know the 4 different.
GigE Knowledge. BODE, Company Profile Page: 2 Table of contents  GigE Benefits  Network Card and Jumbo Frames  Camera - IP address obtainment  Multi.
Make the most of your energy June 2008 Power Meter 800 PowerLogic ® Power Meter 8ECC.
Control Activity & Industry Services
LabView Users Group Meeting June 20 th, 2006 Process Control Using Compact Field Point/Labview Real-time Michael Tockstein Microelectronics Technology.
ADAM-5000/TCP- Distributed Ethernet I/O
eAutomation Enabler – Advantech Industrial NETworking
Alternative Energy Class Room Automation Control System Lighting and Temperature Control By: Al Woodward EET-2011.
SCADA and Telemetry Presented By:.
1 © Red Lion Controls Inc. Introducing the RAM 9000.
K200S Introduction.
Viking Pump Flow Manager - Phase 2 Senior Design May
ASAB New Additions Extended Bypass Models Ethernet Modules Remote Control Panel.
A BRIEF INTRODUCTION TO FIELDBUS 4 hf NETLOGIC PLC TRADITIONAL CABLING SYSTEM TERMINAL BOARD.
Page 1 ADAM-6000 Web-enabled Smart I/O Γιάννης Στάβαρης Technical Manager Ιούνιος 26, 2007.
Identifying SLC 500™ System Components. SLC 500 System Options  The SLC 500 line of processors comprises both fixed and modular processor styles.:
Chapter 7 AC 800M Hardware Course T314.
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
Schutzvermerk nach DIN 34 beachten XC200 Hardware Overview.
DLS Digital Controller Tony Dobbing Head of Power Supplies Group.
1 Product & Technology Quality Excellence Support American Global Products Product & Technology TeSysPort Ethernet Interface for TeSys June 5, 2007.
Product range/ALPHA-E-0001-tri-20/04/03 ALPHA Micro Controllers A single multi-functional unit instead of multiple components ALPHA / ALPHA XL Products/ALPHA.
M340 Modbus Plus Proxy Link legacy systems to Ethernet
Internet 0 for Industrial Applications Fred Cohn 13-Dec-07.
Welcome to Product Workshop 2008!. The Indication Group Panel Meters Large Displays Sensors Temperature Controllers Signal Conditioners.
YASKAWA VS-606 V7 COMPACT VECTOR - CONTROLLED INVERTER FOR GENERAL USE 230V (Single-Phase).1Kw ~ 3.7Kw (.13HP ~ 5HP) 230V (Three-Phase).1Kw ~ 7.5Kw (.13HP.
Chapter 3 Programming a Programmable Controller. Objectives Describe the available options for programming a PLC. Explain what online is in comparison.
CIMON TOUCH KDT SYSTEMS Introduction  Excellent Durability  The mobile CPU of the TOUCH gives excellent durability under industrial environment.
Profibus. PLC PROFIBUS active stations, master devices DriveActuatorTransmitter passive stations, slave devices Sensor Drive logical token ring between.
Managed by UT-Battelle for the Department of Energy SCL Vacuum Control System Upgrade Derrick Williams
New product introduction:
LIGO-G9900XX-00-M LIGO II1 Why are we here and what are we trying to accomplish? The existing system of cross connects based on terminal blocks and discrete.
DriveWorksEZ for the G7 Drive The Intelligent Choice for Distributed Control PP.DWEZ.01 Date: 7/30/06, Rev:
1 © Red Lion Controls Inc. Graphite HMI Series Graphite Series.
PROGRAMMABLE LOGIC CONTROLLER. Control Systems Types  Programmable Logic Controllers  Distributed Control System  PC- Based Controls.
TS8000 TS8000 Series HMI. Key Features Standard support for current SSD products. Support For Common third party Hardware. Programming software Included.
Pag. 1 VAT200, General Purpose AC Drive Mini AC Drive VAT200.
CompactLogix Controllers Portfolio
October 2010 SmartAXIS Controller. High Performance, Compact and Economical.
Modular C ontroller S eries Product Introduction.
Lesson 1 PLC BASICS. PLC Definition  Programmable Logic Controllers are industrial computers that control machine and other applications.  PLC have.
Chapter 1: Introduction to the Personal Computer
Industrial communication networks
C1300 advanced circular chart recorder
Reveal™ Touch Screen Product Overview
Distributed Control for drives
2500 Series® Compact System Components
Session III Architecture of PLC
Instructor Materials Chapter 1: Introduction to the Personal Computer
Identifying SLC 500™ System Components
Programmable Logic Controllers (PLCs) An Overview.
2500 Series® Compact System Components
PLC Hardware Components.
TS8000 Series HMI.
Delta PLC AH500 Series for High-End Automation System Applications Automation for a Changing World.
Integrated gateway-server
Presentation transcript:

AC890PX High Power Inverter

The history of SSD LINK LINK 1 was the first fiber optic peer-to-peer network of its kind. Its sole purpose was to control a coordinated drive system. Used primarily with the 570L DC Link drive and later, the 590L and much later, the 620L AC vector Link drive. With speeds of 2.7MB, and all modules communicating at the same time, it was blazing fast for its time. Fiber optic cable was thin, light, and was not plagued with electrical noise issues. A single loop of fiber, linking drive to drive was the only signal connection required for a coordinated system.

The history of SSD LINK There were Link 1 modules for digital and analog I/O, serial communication and processor modules that provided memory to hold function blocks. (570L, 590L drives had no function block memory) A one-page CRT Link touchscreen provided operator input and monitoring. ConfigEd and SAM software suite was used to program all components and monitor their performance on-line.

A typical LINK 1 system DIAGNOSTICS SPEED DEMAND E M Local ProgJog Health Run Brake Local EUROTHERM DRIVES 620 VECTOR LINK SERIES PLC 590L620LProcessor Analog I/ODigital I/O Gateway Repeater CRT Touchscreens Gateway

The history of A Link techbox was designed to fit into a standard drive, allowing it to be used as a Link drive. No more special Link drive. Link 2 started to consolidate the highly distributed control of LINK 1, with the introduction of the LinkRack and LinkScreen Individual LINK 1 modules that needed their own 24V supply and RTN cards were replaced by a Link rack that would fit up to 3 I/O cards and 1 RTN card. Racks could hold a communication card to talk directly to a PLC. No more gateway module, no more gateway repeater. LINK 2

The history of The touchscreen was now LCD based, and could be configured with multiple pages of screens. It also doubled-up as a rack. Racks and screens were powered by 120VAC, eliminating large 24VDC power supplies used in LINK 1 systems. Both the rack and screen had enough memory and storage to hold a 6- section drive system configuration. DSD software now had the monitoring part built-in. No more separate packages for designing and set-up/monitoring. LINK 2

A typical LINK 2 system PLC 590+ Analog I/O Digital I/O Link Rack 690+ LL LCD Touchscreen Analog I/O Digital I/O

Introducing LINKnet is an Ethernet based modern version of our SSD LINK fiber optic system. CAT-6 cables replace fiber. No more repeaters. It caters to existing LINK customers whose fiber optic systems are several years old, and in need of modernization. A LINKnet techbox that fits in the same spot as the LINK techbox on 590+ and 690+ drives. 2014

Introducing Customers get to keep their panels, 590+ and 690+ drives, and change out only the techbox and the fiber optic network. Huge savings for the customer, resulting in future business. Link I/O will be replaced by Ethernet remote I/O modules. Any Link touchscreens will be replaced by TS8000 in phase 1. It is the new peer-to-peer network for 590+ and 690+ drive systems. 2014

New LINKnet Hardware LINKnet HMI Ethernet peer to peer support & Modbus TCP/IP fieldbus Phase III (December 2015?) LINKnet 890 Option Card with Ethernet Peer to Peer Support & Modbus TCP/IP fieldbus Phase II (March 2015) Phase I (May 2014) LINKnet Tech. Box with Ethernet Peer to Peer Support & Modbus TCP/IP fieldbus + Remote I/O support

LINKnet Techbox Mini USB programming port Ethernet RJ-45 peer-to-peer port Reserved Do not use External power 24VDC (not essential) 6055-LNET all frames 690+ frames C-K 6053-LNET frame B only 6057-LNET Din rail mounted for extra processing

Current Peer to Peer Support TS L5392 L5300 LINK 2 fiber optic 690+ PLC FireWire TS8000 L5300 PLC AC890

Future Peer to Peer Support LINKnet DC590+ AC690+ TS8000 AC890 3 rd Party HMI 3 rd Party Remote I/O Modbus TCP/IP Modbus TCP PLC

I/O support

Modular Input and Output Modules A node can consist of a combination of analog, digital, and specialty I/O modules, with different potentials and signals (up to 230VAC). Up to 64 I/O modules* can be inserted in a node. * System can support up to 250 I/O modules with Bus Extension modules. Over 400 different I/O modules Digital Inputs & Outputs VDC & VAC (1, 2, 4, 8 & 16 Channel Devices) Analog Inputs & Outputs 0-10 V, +/-10 V, 4-20 ma, thermocouple, RTD; 3 PH power measure. (differ. & single ended) Specialty Modules Counters, encoders, serial interface (RS232 & RS485), AS Interface, Vibration, DC Drive

Bus Extension Modules Bus Extension Modules make panel layout flexible. Max. no. of I/O modules: 250 Max. no. of bus extensions: 10 Cable length: 5m Cable: STP-cable with RJ45 (straight through cable)

DSE programming & on-line Software

ConfigEd / DSD > DSE highlights DSE replaces ConfigEd, SAM and DSD as the software tool for both designing and on-line use. Version 3.00 or later supports LINKnet. Newer platform, compatible with Windows XP, 7, 8, 32/64 bit. Newer features like remote IP address access. More intuitive interface, with icons for frequently used features. Monitoring and Charting of any parameter from any address. Several other ease-of-use improvements.

LINKnet - DSE advantages No more -100 to + 100% limitation, as in LINK 1 and 2. No more 83.33% scaling for speed signals. No more 50% scaling for torque and current signals. Easy setup and mapping for I/O and communication cards. Update on-line from within DSE. No more Manger Import/export projects from inside DSE. No more Manager.

DSE packages DSE Development is the designer’s package. It creates and manages projects and configurations of entire lines. DSE Runtime is the maintenance package. It has full editing rights, same as DSE Development, but it cannot be used to program new projects or new modules. If you have ConfigEd or DSD, you will need to purchase the equivalent DSE package. If you have DSE already, there is no charge. Just update to version 3.00 or later by checking for updates from within DSE.

Read and write directly to Ethernet I/O

Read and write directly to PLC or HMI

Mapping PLC and HMI I/O

Access drive parameters by Tag number

Network Diagnostics System Control block now monitors Ethernet network integrity System Control block now monitors TB to drive comms All these outputs can be actioned as desired or displayed on HMI Ethernet comms TB to drive comms

Retrofit plan

Upgrade scope When trying to specify an upgrade for an existing LINK line, use the following guidelines: Is it a LINK 1 system or a LINK 2 system? How many drive sections? How many locations/enclosures? How many points of analog and digital I/O? Where is the I/O distributed? How many touchscreens? How many total pages? How much extra processing in various modules? Any fieldbus communication present?

LINK 1 to LINKnet Is it a LINK 1 system or a LINK 2 system?LINK 1 How many drive sections?1 DC, 2 AC (new drives) How many locations/enclosures?3 How many points of analog and digital I/O?Analog 4+1, Digital 6+4 Where is the I/O distributed?1 location How many touchscreens? How many total pages?3 screens, 3 pages, no proc. How much extra processing in various modules?1 page Any fieldbus communication present?Ethernet DIAGNOS TICS SPEED DEMAND E M Local ProgJog He alt h RunRun B ra ke Lo cal EUROTHERM DRIVES 620 VECTOR LINK SERIES PLC 590L620LProcessor Digital I/O Gateway Repeater CRT Touchscreens Gateway DIAGNOS TICS SPEED DEMAND E M Local ProgJog He alt h RunRun B ra ke Lo cal EUROTHERM DRIVES 620 VECTOR LINK SERIES 620L Analog I/O LINK 1 Fiber optic 1 page 1 DC drive2 AC drives 4 in, 1 out 6 in, 4 out 3 screens 1 page each Ethernet PLC

LINK 1 to LINKnet solution DIAGNOS TICS SPEED DEMAND E M Local ProgJog He alt h RunRun B ra ke Lo cal EUROTHERM DRIVES 620 VECTOR LINK SERIES PLC 590L620LProcessor Digital I/O Gateway Repeater CRT Touchscreens Gateway DIAGNOS TICS SPEED DEMAND E M Local ProgJog He alt h RunRun B ra ke Lo cal EUROTHERM DRIVES 620 VECTOR LINK SERIES 620L Analog I/O LINK 1 Fiber optic TS8000 Remote I/O Protocol converter * E-Switch LINKnet Ethernet Modbus TCP PLC

LINK 2 to LINKnet Is it a LINK 1 system or a LINK 2 system?LINK 2 How many drive sections?1 DC, 2 AC (same drives) How many locations/enclosures?3 How many points of analog and digital I/O?Analog 4+1, Digital 6+4 Where is the I/O distributed?1 location How many touchscreens? How many total pages?1 screen, 3 pages, 3 proc. How many Racks?1 rack, 4 processing pages. How much extra processing in various modules?3+4 pages Any fieldbus communication present?Ethernet L5392 L5300 LINK 2 fiber optic 690+ PLC 1 page 1 DC drive 2 AC drives 1 screen 3 pages 3 pages processing Ethernet PLC Dig. 6 in, 4 out Ana. 4 in, 1 out Comms: Ethernet 4 pages processing

LINK 2 to LINKnet solution L5392 L5300 LINK 2 fiber optic 690+ PLC TS8000 Remote I/O Modbus TCP PLC E-Switch LINKnet Ethernet

SSD Drives has over 1200 LINK systems in the field. There are many more designed by our Integrators. Most are ripe for modernization. LINKnet opens the door to: Sales opportunities Modern Ethernet network Same look and feel for the Customer Easier integration with PLC and I/O Customer retention Upgrade opportunities

Thank You!