“My Room” Project The Massachusetts Code Book and the rules that apply.

Slides:



Advertisements
Similar presentations
Code Analysis:Accessibility Colleen MacEachern & Stephanie Novak.
Advertisements

Classroom Safety. Fire & Life Requirements as per State Education Dept The following list relates to the classrooms and adjacent areas. They are provided.
7 | Means of Egress (Life Safety Code)
Residential Building Codes and Preferences For the Designer Sleeping Area Architectural Design.
ADA Enhanced Condo Client: Kelly Heller Blind 48 years of age Sculptor
Architectural Design Copyright Texas Education Agency (TEA) 1.
Floor-Plan Dimensions and Notes
Means of Egress Talia Ordonez Alex Prodanov Margarita Binkin Team.
of NFPA 101 Life Safety Code 2000 Edition Means of Egress
DEPARTMENT OF DEVELOPMENT SERVICES BUILDING DIVISION Ronald L. Lynn, Director/Building Official Gregory J. Franklin, Assistant Director Neil Burning, Manager.
Grimsby Secondary School
Room Planning and Sleeping Area
Accessibility.  A building code is a set of rules that specify the minimum acceptable level of safety for buildings. The main purpose of building codes.
IRC 2009 Habitable Attics.
Michigan Department of Licensing and Regulatory Affairs Bureau of Construction Codes.
Visitability Standards Dan McNabb, Deputy Building Official Planning and Development Review Department.
Source of Specifications:
Interpret drawings of domestic structures. Drawing Layout The drawings on the next two pages show how a construction drawing can be laid out to show the.
Identifying Information: Common Areas - 1 none LEVEL 2.
Drafting and Dimensioning the Architectural Floor Plan
Tom Kader Chief Electrical Inspector Spaces About Electrical Equipment Sufficient access and working space shall be provided and maintained about.
PERFORMANCE & CODE ANALYSIS TIMBer Inc. ·Brooke Fedder · Marie Rottschaeffer· Izzie Molinuevo· Tena Pettit·
Building Codes and Interior Design
Elevations, Layout and Drawing Technique.
1 HVACR116 – Trade Skills Plan Views Elevations Plan Views Elevations.
Room Relationships and Sizes
Chapter 12 Sleeping Areas Types of Sleeping Areas Bedrooms Average size – 100 to 200 square feet 3 items must accommodate a minimum size bedroom –Single.
QUIRKY HQS INSPECTIONS Seanna Collins Lincoln Housing Authority September 16, 2015.
Building Codes Intended to protect the public by establishing minimum standards of building safety.
Certificate of occupancy By Borja Gorina, Dani Fàbregas and Eric Salgado.
Housing Safety and Zoning Code Enforcement Initiative Department of Health and Social Services Environmental Inspections Division.
Code Analysis. Identify the relevant codes  Local building code  Local accessibility code (or ADA)  Local fire code (or the NFPA)  Mechanical, electrical.
EDT Elevations1 Weekend Cabin Retreat Project Elevations Sacramento City College EDT 300/ENGR 306.
Hunter McWhorter Mark Menard Steven Hammock. Inspectors never fail to check the required emergency-egress window from a sleeping room. At least one window.
By: Dakota White.  Slides  Elements  Project Description  Client Survey  Bubble Diagram  Design Sketches  Code Considerations  Habitat for Humanity.
Difference between 2003 and 2009 ICC/ANSI A117.1 applicable to the Plumbing Subcode Presented by: John N. Terry Tom Pitcherello.
Code Analysis: Don’t try this at home. Identify the relevant codes  Local building code  Local accessibility code (or ADA)  Local fire code (or the.
HVACR116 – Trade Skills Plan Views Elevations. Plan Views.
EDT Cabin Design Project - Elevations1 Weekend Cabin Retreat Project Elevations Sacramento City College EDT 300 Kenneth Fitzpatrick, P.E.
ID 440: Project 1: Hospitality Design
Affordable housing project
Final Assignment part 1: revise stairs Some minor markups.
ID 234 Building Codes Fall 2012 Means of Egress Chapter 4.
Applying Factoring Chapter 10. Solve.  (x – 3)(x – 4) = 0.
By Angela Forte, Michelle Gagnon, Kerri Morse, & Sam Oosterman.
Means of Egress Part 3 Chapter 4.
Maine State Fire Marshals Office1 Laws and Codes Relating to Existing Apartment occupancies in the State of Maine Mark Stevens CFI-II, CFPS, CFPE Inspections.
Codes and costing construction + materials II. Building Code (780 CMR) Building Code (780 CMR) Accessibility Code (521 CMR) Accessibility Code (521 CMR)
Drafting 2 (Arch) Quiz Review #2 Quiz Review. 1.Name the building parts that have been preassembled either in a plant or on-site. Sills Jambs Mullions.
Toilet design Many different regulations 1. guess what toilet features might be regulated? building code? accessibility code? universal design?
Building Occupancy.
ROOM DESIGN AND CONSIDERATIONS APPLICATIONS OF TECHNOLOGY.
BEDROOMS & BATHROOMS- PRIVATE ZONES. BEDROOMS- REQUIREMENTS: All Sleeping Areas should be near: Each-other (Bedrooms all near each-other OR master in.
Room Planning and Sleeping Area. Three Basic Areas Sleeping Area Living Area Service Area.
Architectural Floor Plan. The following are the steps necessary to complete a typical architectural floor plan. 1. Wall Layout 2. Windows 3. Doors 4.
Development Planning (Health and Sanitary) Regulations 2016 Scope To revise and update Part V of Chapter 10 of the Code of Police Laws and GN110/34 To.
Safety Rule #1 Open flames are not allowed without first obtaining a permit. The exception to this rule is during a period of closely supervised instructions,
Standard  Students will prepare residential floor plans.
Garrett Plumstead Nick Pantelakis Eston slacks
Architectural Floor Plan
Planning The Electrical System
2009 IBC Egress Issues in Commercial Buildings, May 25, 2011
Drawing Floor Plan.
February 27, 2007 Drill – ELEVATIONS
Smoke Detector Installation Guidelines
Week 5 Drafting and Dimensioning the Architectural Floor Plan.
Building standards Mr. Da Silva.
Floor Plans and Symbols
Objective 7.02: EXPLAIN the essentials of home baths
Elevations, Layout and Drawing Technique.
Presentation transcript:

“My Room” Project The Massachusetts Code Book and the rules that apply

780 CMR 5304 MINIMUM ROOM AREAS Minimum Area. Every dwelling unit shall have at least one habitable room that shall have not less than 150 square feet of gross floor area Other Rooms. Other habitable rooms shall have a floor area of not less than 70 square feet (6.5 m2). Exception: Kitchens Minimum Dimensions. Habitable rooms shall not be less than seven feet (2134 mm) in any horizontal dimension. Exception: Kitchens Height Effect on Room Area. Portions of a room with a sloping ceiling measuring less than five feet (1524 mm) or a furred ceiling measuring less than seven feet (2134 mm) from the finished floor to the finished ceiling shall not be considered as contributing to the minimum required habitable area for that room.

780 CMR 5305 CEILING HEIGHT Minimum Height. Habitable rooms, hallways, corridors, bathrooms, toilet rooms, laundry rooms and basements shall have a ceiling height of not less than seven feet (2134 mm). The required height shall be measured from the finish floor to the lowest projection from the ceiling.

Exceptions: 1. Beams and girders spaced not less than four feet (1219 mm) on center may project not more than six inches (152 mm) below the required ceiling height. 2. Ceilings in basements without habitable spaces may project to within six feet, eight inches (2032 mm) of the finished floor; and beams, girders, ducts or other obstructions may project to within six feet, four inches (1931 mm) of the finished floor. 3. Not more than 50% of the required floor area of a room or space is permitted to have a sloped ceiling less than seven feet (2134 mm) in height with no portion of the required floor area less than five feet (1524 mm) in height. 4. Bathrooms shall have a minimum ceiling height of six feet eight inches (2036 mm) over the fixture and at the front clearance area for fixtures as shown in 780 CMR Figure A shower or tub equipped with a showerhead shall have a minimum ceiling height of six feet eight inches (2036 mm) above a minimum area 30 inches (762 mm) by 30 inches (762 mm) at the showerhead.

780 CMR 5310 EMERGENCY ESCAPE AND RESCUE OPENINGS Emergency Escape and Rescue Required. Basements with habitable space and every sleeping room shall have at least one openable emergency escape and rescue opening. Where basements contain one or more sleeping rooms, emergency egress and rescue openings shall be required in each sleeping room, but shall not be required in adjoining areas of the basement. Where emergency escape and rescue openings are provided they shall have a sill height of not more than 44 inches (1118 mm) above the floor. Where a door opening having a threshold below the adjacent ground elevation serves as an emergency escape and rescue opening and is provided with a bulkhead enclosure, the bulkhead enclosure shall comply with 780 CMR The net clear opening dimensions required by 780 CMR 5310 shall be obtained by the normal operation of the emergency escape and rescue opening from the inside. Emergency escape and rescue openings with a finished sill height below the adjacent ground elevation shall be provided with a window well in accordance with 780 CMR

Minimum Opening Area. All emergency escape and rescue openings shall have a minimum net clear opening of 5.7 square feet (0.530 m2). Exceptions: 1. Grade floor openings shall have a minimum net clear opening of five square feet (0.465 m2). 2. Double hung windows used for emergency escape shall be permitted to have a net clear opening of 3.3 square feet (0.31 m2) provided that at least one operable sash meets the minimum height and width required by 780 CMR and and operational constraints defined by 780 CMR Minimum Opening Height. The minimum net clear opening height shall be 20 inches (508 mm) Minimum Opening Width. The minimum net clear opening width shall be 24 inches (610 mm) Operational Constraints. Emergency escape and rescue openings shall be operational from the inside of the room without the use of keys or tools.