Retrofitting My Home with Fire Sprinklers Greg Kleinberg, Deputy Chief – Fire Marshal Medford Fire-Rescue.

Slides:



Advertisements
Similar presentations
Sprinkler Systems and Standpipe Operations
Advertisements

BUILDING CONSTRUCTION
ENERGY CONSERVATION: HOME WRAP, INSULATION, AND STOPPING AIR LEAKS.
Basics of Fire Sprinkler Design
KCDC Knox County Development Corporation Virtual Building 50,000 SF Manufacturing- 4,300 SF office building.
Unit 3 Fire Suppression Section 1 Detection and Alarm Systems.
UL/FM Fire Pump Systems Lunch & Learn 04/18/05
Chapter 20 Plumbing Plans.
Joining, Installing, and Supporting Pipe
Effectiveness of Sprinkler Systems
N.F.P.A. 13R Justin Bohlmann FIR-204.
13D Systems What, Why and How Oregon Fire Sprinkler Coalition.
Residential Fire Sprinklers A Little Bit of History and The What, Where, Who, When and How Questions Richard J. Prospal – American Society of Sanitary.
Residential Fire Sprinklers in the 2010 CA Codes
RESIDENTIAL FIRE SPRINKLER SYSTEMS
Backflow Preventor. (4) The Contractor V may install the cross-connection backflow prevention device as defined in this chapter on new installations.
City of Blaine Residential Fire Sprinklers Your Personal Fire Fighter =
Residential Fire Sprinklers Building Codes Plan PreparationPlan Preparation The sprinkler contractor should be required to submit a set of complete, detailed.
Fire Sprinklers A Presentation to the Canadian Home Builders Association Technical Research Committee Sean Pearce National Marketing Manager Canadian Automatic.
WATER FOR FIRE PROTECTION (Chapter 26) Basic factors of fire – Rapid oxidation of combustible materials – A combination of oxygen, fuel, and heat is required.
Purpose of Standpipe and Hose Systems
Chapter 9. Please read chapter 9.  Please review, know and understand the terms related to fire protection page 284.  Know the Classifications of.
Automatic Sprinkler Systems
Home Fire Sprinkler Mythbusters Overcoming Barriers Oregon Fire Sprinkler Coalition.
NFPA 13: Installation of Sprinkler Systems
Oregon Fire Sprinkler Coalition
Integration of Hydronic Thermal Transport Systems with Fire Suppression Systems ASHRAE Winter Meeting 2001 WALTER M. JANUS, PE URS Corp., Washington, DC.
Module C Sprinkler systems (4-20)
Fresno County Fire Protection District. Fire Sprinklers Systems Residential – 13D October 30, 2007.
Technical Review Needed Fire Flow Analysis Developer Services Summit November 16, 2010 Engineering - Asset Planning Joe Dugandzic, PE.
Road Map to a Green Tag Paperwork=Time=Money. Questionnaire If you could change any one major thing inside the Fire Community Services process what would.
INTRUSION ALARM TECHNOLOGY
Energy Performance and Moisture Control of Ceilings and Roofs 1.
Energy Star Emone McDowell 3b 3b. Energy Star Info To earn the ENERGY STAR, a home must meet guidelines for energy efficiency set by the U.S. Environmental.
Residential Fire Sprinkler Concerns. Water Supplier Reliability Issues Water Supply Water Facilities Water Quality Cost.
Chapter 18 Plumbing Plans.
Residential Construction Unit 5 Energy Efficiencies and Mechanicals Mr. Todzia.
Plumbing Prints Unit 15.
Architectural Graphics UNT in partnership with TEA. Copyright ©. All rights reserved.
Week 3. Electrical Code 1. all electrical outlets run off a pigtail from main line 2. Each Circuit is wired directly into circuit panel - no junction.
INSTALLATION & COMMISSIONING. 5WSS Installation Hanging the Unit Hanging the Unit Location Considerations Location Considerations Refrigerant Piping Refrigerant.
Water Source.  SC has no requirements to be an irrigation contractor  Other states do NC to be certified NC to be certified.
Copyright © Texas Education Agency, All rights reserved. Architectural Graphics.
HVACR116 – Trade Skills Longest length method.
Code Officials and the Code Process.  To design the interior of the building in conjunction with codes, standards and federal regulations required in.
Backflow Prevention for Fire Sprinkler Systems State of Illinois Plumbing Code.
Fire Protection Systems Chapter 6. Fire Protection Systems Most of the time you will work with an electrical engineer or fire-protection designer to coordinate.
Features & Benefits of ENERGY STAR Qualified New Homes.
Code Officials and the Code Process.  Concentrates on the code process as a whole.  Different type of code officials  Various steps that are taken.
Friction Loss Tutorial Used in conjunction with the Friction Loss Check Sheet and any Irrigation Plan.
Sprinkler Loads on Trusses
Residential Fire Sprinklers for Compact Development.
Plumbing Radiant Heating & Cooling Turf Conditioning Permafrost Ice and Snow Melt Ecoflex ® SupportSustainabilityEngineered PolymerCommercial SystemsIntroductions.
Sprinkler Loads on Trusses Educational Presentation.
Unico Tips and Tricks. First Steps Layout and material list to be done by the salesman Wear Hospital Style Booties, if working in a non-drop cloth area.
Tips on how to winterize your lawn sprinkler system Benefits of using Lawn Sprinkler Systems.
Coachella Valley Water District Water Service and Water Meter Sizing Criteria Workshop April 13th from 10:30-11:30am April 19th from 1:30-2:30pm 1 CVWD.
What is the difference between Annual and Five- year sprinkler test.
Fire Protection Systems Chapter 9 IBC 9th Edition Amendments
Plumbing system fundamental and design course
Tips on how to install irrigation systems
Heating Ventilation and Air Conditioning
Borbotech BV • Tel.: +31(0) • •
Zurn Fire Valves - Overview 101
Background and Objectives
How & When to Get Permits for Work in Your Home
Fire Service Professionals
House Construction Budget Plan
Building standards Mr. Da Silva.
Presentation transcript:

Retrofitting My Home with Fire Sprinklers Greg Kleinberg, Deputy Chief – Fire Marshal Medford Fire-Rescue

Why I Did This Why I Did ThisExperienceKnowledge

The House The House 1995, 1,740 sq. ft. Single Story Wood Framed with Attic and Underfloor Access

The Fire Sprinkler Design Parameters The Fire Sprinkler Design Parameters Water Source Known 60 psi at hose bibs Known 60 psi at hose bibs Known 5/8” water meter (not sufficient) Known 5/8” water meter (not sufficient) Type of System NFPA 13D flow-through (also known as passive purge) looped NFPA 13D flow-through (also known as passive purge) looped and ending at a washing machine (multi-purpose system) and ending at a washing machine (multi-purpose system) Head Type and Spacing Globe GL4906 concealed pendants 155 O Globe GL4906 concealed pendants 155 O 16’ x 16’ area of coverage 16’ x 16’ area of coverage

The Water Supply The Water Supply Current Conditions 1” Tap Street to Meter 1” Tap Street to Meter 1” PVC Meter to House 1” PVC Meter to House New Conditions ¾” iPERL Water Meter ¾” iPERL Water Meter

Design Resources Design Resources NFPA 13D (2013) Residential Sprinkler System Design Made Easy Residential Sprinkler Sizing Table

The Plans The Plans Required Information (NFPA 13D) 1. Address (if known) 2. Size and type of domestic line, including length to city connection 3. Water meter size 4. Current static water pressure 5. Interior walls 6. Model, manufacturer, temperature, orifice size, and spacing requirements of sprinklers 7. Type of pipe 8. Hanger spacing requirement per the pipe manufacturer 9. Riser detail 10. Installing contractor information 11. Preliminary hydraulic calculations

The Plans The Plans

Hydraulics Hydraulics Inputs: Residential Sprinkler Sizing Table AT2904 Pt=Psup-PLsvc-PLm-PLd-PLe-Psp

Hydraulics Hydraulics Allowable Length of Pipe from Meter to Furthest Sprinkler

Hydraulics Hydraulics Allowable Length of Perimter of Loop

Hydraulics Hydraulics Allowable Length of Perimeter of Loop

The Materials The MaterialsMaterials Piping Piping Fittings Fittings Heads Heads Head covers Head covers Hangers Hangers Solvent Cement Solvent Cement Pipe thread putty Pipe thread putty Drain valve Drain valve 2 x 4’s 2 x 4’s Insulation Insulation

The Permit Process The Permit Process Plan Review Submittals Drawings Drawings Hydraulics Hydraulics Cut sheets Cut sheets Water supply information Water supply information

The Install The Install Head Location Marking Clearing Insulation

The Install The Install Installing Pipe and Hangers

The Install The Install Cutting Ceiling Holes Installation of Heads

The Install The InstallRiser Connection to Washer Connection to Water Supply

The Inspection Approvals The Inspection Approvals Rough-in Inspection

The Insulation The Insulation Keeping All Pipe in Heated Space

The Inspection Approvals The Inspection Approvals Final Inspection

The Final Cost The Final Cost Materials & Labor Materials Materials Sprinkler Supplies$1,247 Sprinkler Supplies$1,247 Batt Insulation 156 Batt Insulation 156 Permit 92 Permit 92 Water meter 35 Water meter 35 Labor (45 hours) 0 Labor (45 hours) 0 Total: $1,530 (0.88 /sq. ft.)

Insurance Savings Insurance Savings State Farm Insurance –5% for partial system –10% for total system

Assurance Assurance Peace of Mind My family is protected My family is protected We wont lose everything in a fire We wont lose everything in a fire

Questions?