Universal Gland Flameproof System Size Ref (Conduit Size) Part No.Gland BodyGland NutMetric/ NPT Max Dia. Over Cores Max Dia. Over Single Core Max No.

Similar presentations


Presentation on theme: "Universal Gland Flameproof System Size Ref (Conduit Size) Part No.Gland BodyGland NutMetric/ NPT Max Dia. Over Cores Max Dia. Over Single Core Max No."— Presentation transcript:

1 Universal Gland Flameproof System Size Ref (Conduit Size) Part No.Gland BodyGland NutMetric/ NPT Max Dia. Over Cores Max Dia. Over Single Core Max No. Of Cores Overall Length A/FA/CA/FA/CThread 16 – 3/8” HAM*0304U 28.631.032.034.0 M16M20 10.510.09 56.0 HAA*0304U3/8”½”60.0 20 – ½” HAM*0404U 28.631.032.034.0 M20 13.0 15 56.0 HAA*0404U½” 60.0 25 – ¾” HAM*0505U 34.037.0 34.0 34.9 SS 37.0 M25 17.9 28 56.0 HAA*0505U3/4”¾”65.4 32 – 1” HAM*0606U 42.045.0 42.0 42.5 SS 45.0 M32 24.020.050 56.0 HAA*0606U1” 65.4 40 – 1 ¼” HAM*0707U 50.054.052.057.0 M40 32.0 75 60.0 HAA*0707U1 ¼” 71.0 50 – 1 ½” HAM*0808U 60.064.060.064.0 M50 35.0 80 63.0 HAA*0808U1 ½” 71.0 63 – 2” HAM*0909U 70.076.0 70.0 69.8 SS 76.0 M63 45.0 100 74.0 HAA*0909U2” 81.0 Description- Group 1 Flameproof Barrier Gland For use with all conduit types via female threaded entry IP66, -60°C to +130°C Exd I&IIC Exe I&II Extb IIIC Intended Use- Groups I and II Zones 1, 2, 21 and 22 Class I Div I BCD (Rigid Conduit Only) Class II Div I EFG Exde I Mb Exde IIC Gb Extb IIIC Db Material- Manufactured in Brass, Nickel Plated Brass and Stainless Steel 316 HA* - Brass HA*M – Nickel Plated Brass HA*S – Stainless Steel Compatible Conduits- Suitable for all conduits including: Rigid - Metallic - Non Metallic Approvals- ATEX directive 94/9/EC (ATEX 95) to standards IEC60079-0:2007 Ed 5, IEC60079-1:2007 Ed 6, IEC60079-7:2007 Ed 4, IEC60079-31:2008 Ed 1 EN60079-0:2009 EN60079-1:2007 EN60079-7:2007 EN60079-31:2008 Certifications- ATEX IECEx CSA SIRA09ATEX1231X IECEx SIRA09.0103X 2310045 The Company’s policy is one of continuous improvement and reserves the right to change specifications at any time without prior notice. NON METALLIC (SILICON) PARTS HAVE PASSED THE REQUIREMENTS OF IEC/EN60079-0 FOR AGE TESTING AND ARE THIRD PARTY APPROVED. 9/5/12 Gland comes complete with two part epoxy putty, gloves and fitting instructions. Putty can be obtained separately if required in 50g and 75g sizes. Part codes EXEP/50 & EXEP/75

2 Universal Gland Flameproof System Size Ref (Conduit Size) Part No.Gland Body90° ElbowMetric/ NPT Max Dia. Over Cores Max Dia. Over Single Core Max No. Of Cores Overall Length A/FA/CA/FConduit 16 – 3/8” HAM*0304E 28.631.032.016mm M20 10.510.0990.0 HAA*0304E½” 20 – ½” HAM*0404E 28.631.032.020mm M20 13.0 1590.0 HAA*0404E½” 25 – ¾” HAM*0505E 34.037.0 34.0 34.9 SS 25mm M25 17.9 28104.0 HAA*0505E¾” 32 – 1” HAM*0606E 42.045.0 42.0 42.5 SS 32mm M32 24.020.050114.0 HAA*0606E1” 40 – 1 ¼” HAM*0707E 50.054.052.040mm M40 32.0 75180.0 HAA*0707E1 ¼” 50 – 1 ½” HAM*0808E 60.064.060.050mm M50 35.0 80146.0 HAA*0808E1 ½” 63 – 2” HAM*0909E 70.076.0 70.0 69.8 SS 63mm M63 45.0 100169.0 HAA*0909E2” Description- Group 1 Flameproof Barrier Gland For use with Liquid Tight Flexible Conduits IP66 -60°C to +130°C Exd I&IIC Exe I&II Extb IIIC Intended Use- Groups I and II Zones 1, 2, 21 and 22 Class I Div I BCD (Rigid Conduit Only) Class II Div I EFG Exde I Mb Exde IIC Gb Extd IIIC Db Material- Manufactured in Brass, Nickel Plated Brass and Stainless Steel 316 HA* - Brass HA*M – Nickel Plated Brass HA*S – Stainless Steel Compatible Conduits- EXLB, EXLT, EXLH, EXLLH, EXLBBT, EXLHC EXSB, EXST, EXSH, EXSLLH, EXSBBT, EXSLHC Approvals- ATEX directive 94/9/EC (ATEX 95) to standards IEC60079-0:2007 Ed 5, IEC60079-1:2007 Ed 6, IEC60079-7:2007 Ed 4, IEC60079-31:2008 Ed 1 EN60079-0:2009 EN60079-1:2007 EN60079-7:2007 EN60079-31:2008 Certifications- ATEX IECEx CSA SIRA09ATEX1231X IECEx SIRA09.0103X 2310045 The Company’s policy is one of continuous improvement and reserves the right to change specifications at any time without prior notice. NON METALLIC (SILICON) PARTS HAVE PASSED THE REQUIREMENTS OF IEC/EN60079-0 FOR AGE TESTING AND ARE THIRD PARTY APPROVED. 9/5/12 Gland comes complete with two part epoxy putty, gloves and fitting instructions. Putty can be obtained separately if required in 50g and 75g sizes. Part codes EXEP/50 & EXEP/75

3 Universal Gland Flameproof System Size Ref (Conduit Size) Part No.Gland BodyGland NutMetric/ NPT Max Dia. Over Cores Max Dia. Over Single Core Max No. Of Cores Overall Length A/FA/CA/FA/C 16 – 3/8” HAM*0304G1 28.631.032.034.0 M20 10.510.0950.0 HAA*0304G1½” 20 – ½” HAM*0404G1 28.631.032.034.0 M20 13.0 1550.0 HAA*0404G1½” 25 – ¾” HAM*0505G1 34.037.0 34.0 34.9 SS 37.0 M25 17.9 2850.0 HAA*0505G1¾” 32 – 1” HAM*0606G1 42.045.0 42.0 42.5 SS 45.0 M32 24.020.05050.0 HAA*0606G11” 40 – 1 ¼” HAM*0707G1 50.054.052.057.0 M40 32.0 7557.0 HAA*0707G11 ¼” 50 – 1 ½” HAM*0808G1 60.064.060.064.0 M50 35.0 8058.0 HAA*0808G11 ½” 63 – 2” HAM*0909G1 70.076.0 70.0 69.8 SS 76.0 M63 45.0 10070.0 HAA*0909G12” Description- Group 1 Flameproof Barrier Gland For use with Liquid Tight Flexible Conduits IP66, -60°C to +130°C Exd I&IIC Exe I&II Extb IIIC Intended Use- Group I and II Zones 1, 2, 21 & 22 Class I Div II ABCD Class II Div I EFG Exde I Mb Exde IIC Gb Extb IIIC Db Material- Manufactured in Brass, Nickel Plated Brass and Stainless Steel 316 HA* - Brass HA*M – Nickel Plated Brass HA*S – Stainless Steel Compatible Conduits- EXLB, EXLT, EXLH, EXLLH, EXLBBT, EXLHC EXSB, EXST, EXSH, EXSLLH, EXSBBT, EXSLHC Approvals- ATEX directive 94/9/EC (ATEX 95) to standards IEC60079-0:2007 Ed 5, IEC60079-1:2007 Ed 6, IEC60079-7:2007 Ed 4, IEC60079-31:2008 Ed 1 EN60079-0:2009 EN60079-1:2007 EN60079-7:2007 EN60079-31:2008 Certifications- ATEX IECEx CSA SIRA09ATEX1231X IECEx SIRA09.0103X 2310045 The Company’s policy is one of continuous improvement and reserves the right to change specifications at any time without prior notice. NON METALLIC (SILICON) PARTS HAVE PASSED THE REQUIREMENTS OF IEC/EN60079-0 FOR AGE TESTING AND ARE THIRD PARTY APPROVED. 9/5/12 Gland comes complete with two part epoxy putty, gloves and fitting instructions. Putty can be obtained separately if required in 50g and 75g sizes. Part codes EXEP/50 & EXEP/75

4 Universal Gland Flameproof System PART No.BODY A/F ‘A’ THREAD ‘B’ MIN BORE ‘C’ ‘D’‘E’NUT A/F ‘F’ EXPQM030325.4M1611.416.033.2525.4 EXPQM040428.0M2015.816.032.028.0 EXPQM050538.0M2519.016.039.038.0 EXPQM060642.0M3226.417.040.044.5 EXPQM070754.0M4032.917.049.557.0 EXPQM080870.0M5043.916.048.070.0 EXPQA030424.0½” NPT11.420.032.525.4 EXPQA040428.0½” NPT15.820.031.528.0 EXPQA050538.0¾” NPT19.020.238.338.0 EXPQA060642.01” NPT26.424.240.044.5 EXPQA070754.01 ¼” NPT32.925.849.557.0 EXPQA080870.01 ½” NPT40.726.148.070.0 Description- For use with standard weight braided antistatic conduit EXB, Material- Body and Nut : Nickel plated Brass Seals: Silicone Intended Use- An electrically discharging cable protection system. This system protects electrical cables and wires from mechanical damage and UV radiation Exe Zones 1, 2, 21 & 22. Gas Groups IIA, IIB, IIC Compatible Conduits- EXB Antistatic Polyamide 12 Conduit Approvals- ATEX directive 94/9/EC (ATEX 95) to standards IEC 60079-0, IEC 60079-7, EN60079-0, EN60079-7, IEC51241-0 IEC51241-1 EN51241-0 & EN51241-1. Certifications- ATEX IECEx BASEEFA ATEX08.0003X IECEx BAS08.0001X The Company’s policy is one of continuous improvement and reserves the right to change specifications at any time without prior notice. NON METALLIC (SILICON) PARTS HAVE PASSED THE REQUIREMENTS OF IEC/EN60079-0 FOR AGE TESTING AND ARE THIRD PARTY APPROVED. 9/5/12

5 Universal Gland Flameproof System PART No.BODY A/F ‘A’ THREAD ‘B’ MIN BORE ‘C’ ‘D’‘E’NUT A/F ‘F’ EXBQM030324.0M1611.418.043.530.0 EXBQM040428.0M2015.816.043.535.0 EXBQM050538.0M2519.016.050.044.5 EXBQM060642.0M3226.418.051.050.0 EXBQM070754.0M4032.918.067.570.0 EXBQM080870.0M5043.916.070.084.0 EXBQA030424.0½” NPT11.420.044.530.0 EXBQA040428.0½” NPT15.820.045.035.0 EXBQA050538.0¾” NPT19.020.254.044.5 EXBQA060642.01” NPT26.424.257.550.0 EXBQA070754.01 ¼” NPT32.925.870.0 EXBQA080870.01 ½” NPT40.726.170.084.0 Description- For use with standard weight braided antistatic conduit EXBB, this system gives additional wear and EMC Protection Material- Body, Nut and Internal components: Nickel plated Brass Seals: Silicone Intended Use- An electrically discharging cable protection system. This system protects electrical cables and wires from mechanical damage and UV radiation Exe Zones 1, 2, 21 & 22. Gas Groups IIA, IIB, IIC Compatible Conduits- EXBB Stainless Steel Overbraided Antistatic Polyamide 12 Conduit Approvals- ATEX directive 94/9/EC (ATEX 95) to standards IEC 60079-0, IEC 60079-7, EN60079-0, EN60079-7, IEC51241-0 IEC51241-1 EN51241-0 & EN51241-1. Certifications- ATEX IECEx BASEEFA ATEX08.0003X IECEx BAS08.0001X The Company’s policy is one of continuous improvement and reserves the right to change specifications at any time without prior notice. NON METALLIC (SILICON) PARTS HAVE PASSED THE REQUIREMENTS OF IEC/EN60079-0 FOR AGE TESTING AND ARE THIRD PARTY APPROVED. 9/5/12