Presentation is loading. Please wait.

Presentation is loading. Please wait.

Universal Gland Flameproof System Size Ref (Conduit Size) Part No.Gland BodyGland NutMetric/ NPT Max Dia. Over Cores Max Dia. Over Single Core Max No.

Similar presentations


Presentation on theme: "Universal Gland Flameproof System Size Ref (Conduit Size) Part No.Gland BodyGland NutMetric/ NPT Max Dia. Over Cores Max Dia. Over Single Core Max No."— Presentation transcript:

1 Universal Gland Flameproof System Size Ref (Conduit Size) Part No.Gland BodyGland NutMetric/ NPT Max Dia. Over Cores Max Dia. Over Single Core Max No. Of Cores Overall Length A/FA/CA/FA/CThread 16 – 3/8” HAM*0304U M16M HAA*0304U3/8”½” – ½” HAM*0404U M HAA*0404U½” – ¾” HAM*0505U SS 37.0 M HAA*0505U3/4”¾” – 1” HAM*0606U SS 45.0 M HAA*0606U1” – 1 ¼” HAM*0707U M HAA*0707U1 ¼” – 1 ½” HAM*0808U M HAA*0808U1 ½” – 2” HAM*0909U SS 76.0 M HAA*0909U2” 81.0 Description-Group 1 Flameproof Barrier Gland For use with all conduit types via female threaded entry IP66, -60°C to +130°C Exd I&IIC Exe I&II Extb IIIC Intended Use-Groups I and II Zones 1, 2, 21 and 22 Class I Div I BCD (Rigid Conduit Only) Class II Div I EFG Exde I Mb Exde IIC Gb Extb IIIC Db Material-Manufactured in Brass, Nickel Plated Brass and Stainless Steel 316 HA* - Brass HA*M – Nickel Plated Brass HA*S – Stainless Steel Compatible Conduits-Suitable for all conduits including: Rigid - Metallic - Non Metallic Approvals-ATEX directive 94/9/EC (ATEX 95) to standards IEC :2007 Ed 5, IEC :2007 Ed 6, IEC :2007 Ed 4, IEC :2008 Ed 1 EN :2009 EN :2007 EN :2007 EN :2008 Certifications- ATEX IECEx CSA SIRA09ATEX1231X IECEx SIRA X The Company’s policy is one of continuous improvement and reserves the right to change specifications at any time without prior notice. NON METALLIC (SILICON) PARTS HAVE PASSED THE REQUIREMENTS OF IEC/EN FOR AGE TESTING AND ARE THIRD PARTY APPROVED. 9/5/12 Gland comes complete with two part epoxy putty, gloves and fitting instructions. Putty can be obtained separately if required in 50g and 75g sizes. Part codes EXEP/50 & EXEP/75

2 Universal Gland Flameproof System Size Ref (Conduit Size) Part No.Gland Body90° ElbowMetric/ NPT Max Dia. Over Cores Max Dia. Over Single Core Max No. Of Cores Overall Length A/FA/CA/FConduit 16 – 3/8” HAM*0304E mm M HAA*0304E½” 20 – ½” HAM*0404E mm M HAA*0404E½” 25 – ¾” HAM*0505E SS 25mm M HAA*0505E¾” 32 – 1” HAM*0606E SS 32mm M HAA*0606E1” 40 – 1 ¼” HAM*0707E mm M HAA*0707E1 ¼” 50 – 1 ½” HAM*0808E mm M HAA*0808E1 ½” 63 – 2” HAM*0909E SS 63mm M HAA*0909E2” Description- Group 1 Flameproof Barrier Gland For use with Liquid Tight Flexible Conduits IP66 -60°C to +130°C Exd I&IIC Exe I&II Extb IIIC Intended Use- Groups I and II Zones 1, 2, 21 and 22 Class I Div I BCD (Rigid Conduit Only) Class II Div I EFG Exde I Mb Exde IIC Gb Extd IIIC Db Material- Manufactured in Brass, Nickel Plated Brass and Stainless Steel 316 HA* - Brass HA*M – Nickel Plated Brass HA*S – Stainless Steel Compatible Conduits- EXLB, EXLT, EXLH, EXLLH, EXLBBT, EXLHC EXSB, EXST, EXSH, EXSLLH, EXSBBT, EXSLHC Approvals- ATEX directive 94/9/EC (ATEX 95) to standards IEC :2007 Ed 5, IEC :2007 Ed 6, IEC :2007 Ed 4, IEC :2008 Ed 1 EN :2009 EN :2007 EN :2007 EN :2008 Certifications- ATEX IECEx CSA SIRA09ATEX1231X IECEx SIRA X The Company’s policy is one of continuous improvement and reserves the right to change specifications at any time without prior notice. NON METALLIC (SILICON) PARTS HAVE PASSED THE REQUIREMENTS OF IEC/EN FOR AGE TESTING AND ARE THIRD PARTY APPROVED. 10/10/2014 Gland comes complete with two part epoxy putty, gloves and fitting instructions. Putty can be obtained separately if required in 50g and 75g sizes. Part codes EXEP/50 & EXEP/75

3 Universal Gland Flameproof System Size Ref (Conduit Size) Part No.Gland BodyGland NutMetric/ NPT Max Dia. Over Cores Max Dia. Over Single Core Max No. Of Cores Overall Length A/FA/CA/FA/C 16 – 3/8” HAM*0304G M HAA*0304G1½” 20 – ½” HAM*0404G M HAA*0404G1½” 25 – ¾” HAM*0505G SS 37.0 M HAA*0505G1¾” 32 – 1” HAM*0606G SS 45.0 M HAA*0606G11” 40 – 1 ¼” HAM*0707G M HAA*0707G11 ¼” 50 – 1 ½” HAM*0808G M HAA*0808G11 ½” 63 – 2” HAM*0909G SS 76.0 M HAA*0909G12” Description-Group 1 Flameproof Barrier Gland For use with Liquid Tight Flexible Conduits IP66, -60°C to +130°C Exd I&IIC Exe I&II Extb IIIC Intended Use-Group I and II Zones 1, 2, 21 & 22 Class I Div II ABCD Class II Div I EFG Exde I Mb Exde IIC Gb Extb IIIC Db Material-Manufactured in Brass, Nickel Plated Brass and Stainless Steel 316 HA* - Brass HA*M – Nickel Plated Brass HA*S – Stainless Steel Compatible Conduits-EXLB, EXLT, EXLH, EXLLH, EXLBBT, EXLHC EXSB, EXST, EXSH, EXSLLH, EXSBBT, EXSLHC Approvals-ATEX directive 94/9/EC (ATEX 95) to standards IEC :2007 Ed 5, IEC :2007 Ed 6, IEC :2007 Ed 4, IEC :2008 Ed 1 EN :2009 EN :2007 EN :2007 EN :2008 Certifications- ATEX IECEx CSA SIRA09ATEX1231X IECEx SIRA X The Company’s policy is one of continuous improvement and reserves the right to change specifications at any time without prior notice. NON METALLIC (SILICON) PARTS HAVE PASSED THE REQUIREMENTS OF IEC/EN FOR AGE TESTING AND ARE THIRD PARTY APPROVED. 9/5/12 Gland comes complete with two part epoxy putty, gloves and fitting instructions. Putty can be obtained separately if required in 50g and 75g sizes. Part codes EXEP/50 & EXEP/75


Download ppt "Universal Gland Flameproof System Size Ref (Conduit Size) Part No.Gland BodyGland NutMetric/ NPT Max Dia. Over Cores Max Dia. Over Single Core Max No."

Similar presentations


Ads by Google