1 VRFA ANNUAL RESPIRTORY PROTECTION

2 THE ADMINISTRATOR

3 THE SPECIALISTS

4 Objectives Train personnel in the proper function, use, cleaning, and maintenance of SCBA Recognize hazards Understand components Understand safety features and limitations Inspection and cleaning of SCBA Test knowledge of SCBA operation, safety, departmental policies/guidelines, and facepiece seals Emergency Procedures

5 VRFA Policies & Procedures Valley Regional Fire Authority Manual of Operations 3501 Respiratory Protection Program Reference: WAC 296-305-4001 WAC 296-62E-7111 King County Training Officers: Respiratory. Protection Program NFPA 1981, 1982, 1404 Effective Date:7/16/01

6 Hazards Extreme Temperatures Flashover Irritant Particles Oxygen deficient Atmosphere Toxic Gases –Hydrogen chloride –Hydrogen cyanide –Carbon dioxide –Phosgene Asphyxiants –Methane –Nitrogen –Propane –Acetylene –Hydrogen

7 Components Cylinder Backpack Harness Audible Alarm First Stage Reg. Second Stage Reg. Facepiece Clear Command ICM 2000 Plus

8 Backpack and Audible Alarm Daily Inspection: 1. Check hoses / backstrap for wear. 2. Cylinder pressure above 4050 psi. 3. Open bottle, listen for audi alarm. 4. Compare bottle gauge with harness gauge +/- 5%. 5. Open emergency bypass. 6. Close cylinder valve. No more than 100 psi drop. 7. Ensure PASS activates after 15 seconds. 8. Don mask and breath down residual pressure.

9 1st Stage & 2nd Stage Regulators 1st Stage2nd Stage

10 Facepiece w/ Clear Command

11 Safety Features Emergency bypassEBBSS

12 Safety Features Cont. ICM 2000+

13 Emergency Procedures 1)Call for Help 2)Open Bypass 3)Transfill 4)Breath from 2 nd Stage 5)Breath from bottle Transfill: Donor above 1000 psi and/or no bell ringing.

14 Inspection, Cleaning, and Maintenance InspectionCleaningDrying

15 Air Cylinder RefillTelesqurt 1. Extend / attach hose to Telesqurt bottle. 2. Close bleeder and open cylinder valve. 3. Adjust regulator at hose reel to maximum 2216 psi. 4. Open fill valve slowly at end of fill hose. 5. Air cylinder is full when you can no longer hear air exchange. 6. Close all valves. Bleed off air in hose. 7. Adjust regulator to 0 psi to avoid possible hazard.

16 Telesqurt Air Supplied System Fully open cylinder Remove hose from SCBA compartment. Make airpack connection Boom connection location

17 R.I.T. Pack Dual System Integrated system with facepiece and 3’ quick connect hose Inventory MSA facepiece 10 foot extension hose w/male & female adapters Tarp (2) 75’ Kevlar rope bags 45 min SCBA bottle Transfill adapter Light sticks Shears

18 Sta. 31 Compressor (not a cascade) Cascade bottle valves should remain open at all times. (Four black knobs-upper right) Ensure regulator is set to 4500 psi. (Big silver knob – middle upper) Open bottle valves slowly to avoid “hot fill”. (Three black knobs - above pressure gauges.) If compressor does not turn on at 5000 psi, check to ensure emergency shutoff button is not pushed in. If CO alarm goes off, open apparatus bay doors to allow fresh air in and clear the alarm.