Presentation is loading. Please wait.

Presentation is loading. Please wait.

Hany EL-Zahaby, MD, Anesthesiologist

Similar presentations


Presentation on theme: "Hany EL-Zahaby, MD, Anesthesiologist"— Presentation transcript:

1 Hany EL-Zahaby, MD, Anesthesiologist
Unstable Tachycardia Hany EL-Zahaby, MD, Anesthesiologist

2 Objectives By the end of this talk we should be able to describe or demonstrate: 1- 1ry and 2ry ABCD surveys 2- Identify unstable from stable tachycardia 3- Identify the rhythm of tachycardia 4- Determine if tachycardia is producing hemodynamic instability or the instability is producing tachycardia

3 Objectives (cont.) 5- Follow the algorithms for tachycardia and cardioversion 6- Operation of a defibrillator/monitor to perform both defibrillation and synchronized cardioversion 7- Provide post-cardioversion care

4 Case Scenario 52-year-old man presented to ED complaining of shortness of breath, palpitations, dizziness and severe chest pain. He is pale and sweaty. His Pulse rate is 178 and blood pressure is 81/50

5 Action Check responsiveness and apply primary and secondary ABCD surveys If not in cardiac arrest or VF and tachycardia is observed, order oxygen-IV-monitor-fluids Identify the rhythm

6 Supraventricular Tachycardia

7 Atrial Flutter

8

9 Atrial Fibrillation

10 Atrial Fibrillation

11 Ventricular Tachycardia

12 Prepare for synchronized cardioversion
Prepare oxygen saturation monitor, suction device, IV line, intubation equipment, call the code team and explain to the patient if awake

13 Premedicate Sedatives and anesthetics: Midazolam ( mg/kg), Diazepam ( mg/kg), Ketamine(1-2 mg/kg), Etomidate ( mg/kg), Thiopentone (3-5 mg/kg), Propofol (1-2 mg/kg)

14 Analgesics: Fentanyl (1-3μg/kg) Morphine ( mg/kg) Pethidine (0.5-1 mg/kg)

15 Synchronized Cardioversion
Is it equal to defibrillation?

16 Why synchronization?

17 When not to use synchronization?
Severely unstable VT

18 Steps for synchronized cardioversion
Turn on defibrillator Attach monitor leads to the patient Ensure proper display of the patient’s rhythm (lead II) Press ‘sync’ control button Look for markers on R waves If no markers, adjust monitor gain until markers on each R

19 Select appropriate energy level for type of arrhythmia
Apply gel to paddles and position it on patient (sternum and apex) Announce to team-members “Charging defibrillators-stand clear” Press charge button on apex paddle (right hand)

20 When the defibrillator is charged state firmly: “I am going to shock on three. One, I am clear. Two, you are clear. Three, everybody is clear” Apply 25 Ib pressure on both paddles Press the “discharge” buttons simultaneously

21 Check the monitor, if tachycardia persists, increase the joules according to the algorithm
Reset to “sync” mode after each synchronized cardioversion If VF occurs, switch to “defibrillation” mode and follow the VF/Pulseless VT algorithm

22 Energy levels: Standard sequence is 100 J→ 200 J → 300 J → 360 J Exceptions: Atrial flutter 50 J→ 100 J→ 200 J→ 300 J→ 360 J Polymorphic VT 200 J→ 300 J → 360 J

23 Post-conversion care:
Closely monitor vital signs Continue oxygen-IV-monitor-fluids Search for a cause for this tachycardia and treat it If VF occurs, recognize need to defibrillate Documentation

24 Conclusion Always start with ABCD
Unstable means either patient or tachycardia Unstable tachycardia is treated with synchronized cardioversion Steps for cardioversion should be strictly followed

25 THANK YOU


Download ppt "Hany EL-Zahaby, MD, Anesthesiologist"

Similar presentations


Ads by Google