1 Trane Variable Water Flow System Installation, Operation & Maintenance Outdoor Air-cooled Water Chiller

2 2 Trane Variable Water Flow System Introduction ‑What is VRF system? System Profile – System & Components Chiller Unit – Nameplate

3 3 A newly designed, digitally controlled air-cooled variable water chiller system – Variable Refrigerant Flow in Refrigeration Loop & Variable Water Flow in water loop – Water used as heat transfer media, no refrigerant in occupied space Digital Chiller Central Controll er RS48 5 Trane Variable Water Flow System Remote Controller High Wall Cassett e Concealed Inflow Water loop Communication line Thermosta t Outflow Water loop Trane Variable Water Flow System What Is It? 3

4 4 6RT8RT10RT12RT14RT Cooling capacity range CGD*100/ 120/ 150/ 175/ 200 Cooling: 24.5kW kW Heating: 24.5kW kW Power source: 220V/60Hz/3Ph 380V/50Hz/3Ph Digital Scroll Compressor Built-in two-speed water pump Fan design delivers reduced noise levels Outdoor Unit

5 5 Cabinet Size (mm) (HxWxD): 1,900 x 1,290 x 600 Digital Fixed Digital Fixed Cabinet Size (mm) (HxWxD): 1,900 x 1,990 x 600 6RT \ 8RT 10RT10RT Digital Fixed Cabinet Size (mm) (HxWxD): 1,900 x 1,990 x RT \ 14RT

6 6 Pulse Width Modulation (PWM signal) % continuous capacity control Superior performance Simplified control parts Pulse Width Modulation (PWM signal) % continuous capacity control Superior performance Simplified control parts Digital Scroll Compressor

7 7 Controllers Wired thermostat is Trane Patented design – Color back light – Last setting for resuming power Central controller is a “must have ” Type of IDWiredRemote Concealed Not Available Cassette Hi-Wall Not available Unit Controllers Type Central Controller (Standard) System Controllers

8 8 Central Controller Multi-zone control Multi-zone control Individual zone control Individual zone control Troubleshooting Troubleshooting Timer setting Timer setting Mode setting Mode setting Patented design Patented design LCD display LCD display Cooling/heating/ ventilation controlCooling/heating/ ventilation control Sleeping mode Sleeping mode Last setting for resuming power Last setting for resuming power Wired Controller Remote Controller Remote ON/OFF fan coil Function setting, temperature regulation, air velocity settingFunction setting, temperature regulation, air velocity setting Sleep mode setting, timer setting functionSleep mode setting, timer setting function Remote control distance ≥5MRemote control distance ≥5M Controllers

9 9 Digit 17: Application ­ N = Normal application ­ E = Earthwise In-Door Unit Selection: Concealed unit: select “Earthwise” application High wall & Cassette: Not available In-Door Unit Selection: Concealed unit: select “Earthwise” application High wall & Cassette: Not available Choose “Earthwise” option in TDS tools to run product configuration report OD Parameter Setting: Set leaving water temp to 5 ° C via central controller OD Parameter Setting: Set leaving water temp to 5 ° C via central controller How to Select “EarthWise”

10 10 Model Number Description C G D K H E A Z R N R R A C ,6, Digit 1,2,3 — Unit Type CGD= Digital Air-Cooled Water Chiller Refrigeration Circuit Digit 4 R = Heat Pump K = Cooling Only Digit 5-7 — Nominal Capacity (Tons) 100 = = = = = 14 Digit 8 — Voltage Selection 2 = 220V/60 Hz/3 ph 5 = 380V/50 Hz/3 ph Digit 9— Airflow Configuration H = Horizontal Digit 10— Refrigerant E = R-22 Digit 11 — Manufacturing Code (defaulted by factory) A = Double Compressors B = Triple Compressors Digit 12 — Central Controller Z = With Central Controller (as standard) Digit 13 — Chilled Water Pump R = Water Pump Digit 14 — Auxiliary Electric Heater in Water Circuit N = None Digit 15 — Ambient Temperature R = Standard Ambient Temperature Set (Standard) Digit 16 — Water Pipe Direction (Face to the Airflow) R = Right Side (Standard) B = Back Side (Optional) Digit 17 — Design Sequence (Not for client) A = First Version B = Second Version Digit 18 — Region V = China A = APR B = MAIR C = LAR

11 11

12 12

13 13

14 14

15 15

16 16

17 17 PVC Pipe Installation Benefits PVC pipe and fitting price is 4 times cheaper than steel pipe’s. PVC Pipe weight is 6 times less than steel pipe’s. Use smaller pipe size because friction loss of PVC pipe is much less than steel pipe’s. Easy transportation, Easier and quicker installation, longevity

18 18 PVC Pipe Installation Benefits Size PVC Class 13.5 (Kg/m) Steel Sch#40 (Kg/m) Size Diff. (time) ½” ¾” ” /4” /2” /2” ” /2” ” ” ”

19 19 PVC Pipe Installation Benefits Size PVC Class 13.5 vs Black Steel Pipe #40 (ERW)* ½”64% ¾”67% 1”64% 1 1/4”67% 1 1/2”63% 2”59% 2 1/2”57% 3”53% 4”37% 5”43% 6”39% 8”33% *The percentage price difference is based on the price in Thailand.

20 20 PVC Pipe Installation Benefits Size PVC Class 13.5 PHP/m Black Steel Pipe #40 (ERW) PHP/m ½”1645 ¾”1957 1” /4” /2” ” /2” ” ” ” ”6151,006 8”1,0461,555

21 21 PVC Pipe Installation Benefits Size PVC Class 13.5 THB/m Black Steel Pipe #40 (ERW) THB/m ½” ¾” ” /4” /2” ” /2” ” ” ” ” ” ,197

22 22 PVC Pipe Installation

23


Download ppt "Trane Variable Water Flow System Installation, Operation & Maintenance Outdoor Air-cooled Water Chiller."