1 Slide #1 6890 GC Detectors - The Flame Ionization Detector

2 Slide #2 6890 GC Detectors - The Flame Ionization Detector - Main Components Igniter Teflon Insulator Collector Interconnect/Spring Electrometer Jet Heater/Sensor Assembly Detector Base Assembly Column Adapter

3 Slide #3 6890 GC Detectors - The Flame Ionization Detector

4 Slide #4 6890 GC Detectors - The Flame Ionization Detector - Theory of Operation 1. H2 - Air Flame 2. Sample is burned in flame 3. When burned produces charged Ions 4. Ions attracted to collector 5. Collector current converted to output via Electrometer

5 Slide #5 6890 GC Detectors - The Flame Ionization Detector FID EPC Flow Manifold Detector Pneumatic Connection Gas Connections to GC FID Flow Measurement Tool FID Jet Plugged FID Jet

6 Slide #6 6890 GC Detectors - The Flame Ionization Detector Complete Detector Assembly FID Collector Removal FID Igniter Replacement

7 Slide #7 Jet TypePart NumberJet Tip id CapillaryG1531-805600.29 mm 0.011" High TempG1531-806200.47mm 0.018" Jet TypePart NumberJet Tip id Capillary19244-805600.29mm 0.011" Packed18710-201190.47mm 0.018" Packed Wide bore18789-800700.030" High Temp Capillary 19244-806200.47mm 0.018" Jets for Capillary-Optimized FID Jets for Adaptable FID 6890 GC Detectors - The Flame Ionization Detector - Jets

8 Slide #8 6890 GC Detectors - The Flame Ionization Detector

9 Slide #9 6890 GC Detectors - The Flame Ionization Detector

10 Slide #10 6890 GC Detectors - The Flame Ionization Detector 6890 EPC Module Original Design New Detector Mini-fold

11 Slide #11 6890 GC Detectors - The Flame Ionization Detector

12 Slide #12 6890 GC Detectors - The Flame Ionization Detector

13 Slide #13 6890 GC Detectors - The Flame Ionization Detector

14 Slide #14 6890 GC Detectors - The Flame Ionization Detector

15 Slide #15 6890 GC Detectors - The Flame Ionization Detector

16 Slide #16 6890 GC Detectors - The Flame Ionization Detector

17 Slide #17 6890 GC Detectors - The Flame Ionization Detector Flame won't light Measure Flows Clean/Replace Jet (6850 Jet Test) Are column and fittings tight ? Is the tank pressure high enough ? Is the Detector ON ?

18 Slide #18 6890 GC Detectors - The Flame Ionization Detector Noisy Baseline Turn off Air/H2 Replace Detector Board/ interconnect/ Teflon Insulators Electronic/Mechanical Problem Still Noisy Check: Filters,Traps,Gasses Clean Jet Verify Column max Contamination problem Yes No

19 Slide #19 HP 6890 - Flame Ionization Detector Planned Maintenance - Replace Jet (per Customer) - Clean/Replace Collector - Inspect interconnect and spring - Inspect ignitor glo-plug - replace if necessary - Measure H2/Air/Makeup Flows - Turn off H2 and measure FID Leakage Current - < 2pA - Ignite FID - monitor background and noise <20 pA and stable - Run customer sample or Agilent Checkout per 6890 Service Manual section 600.