TROBLESHOOTING GAS CHROMATOGRAPHY (GC) Parto Zist Behboud Reza Daj 8/16/2014.

Similar presentations


Presentation on theme: "TROBLESHOOTING GAS CHROMATOGRAPHY (GC) Parto Zist Behboud Reza Daj 8/16/2014."— Presentation transcript:

1 TROBLESHOOTING GAS CHROMATOGRAPHY (GC) Parto Zist Behboud Reza Daj 8/16/2014

2 Today’s Overview Introduction 1 Troubleshooting Approach 2 Pressure Problems 3 Leaks 4 Component Malfunctions 5 Baseline Problems 6 Peak Problems 7 Data Problems 8

3 Introduction Flow Controller Injection Port Detector Column Oven Column Gas Cylinder Electric Signal Data Processor

4 T ROUBLESHOOTING A PPROACH Do It Yourself Reference Points Common Problems Safety Getting the Facts Isolating the Source Repair Strategy Preventive Maintenanc e

5 Split/SplitlessSplit/Splitless1 On-columnInjectionOn-column Injection 2 Programed Temperature VaporizationProgramed Temperature Vaporization 3 Sample Injector System

6 Detector

7 Carrier Gas He and N 2 are usually used. (In the case of a capillary column, helium is desirable) The gas of 99.999% or more of purity is used. Detector Gas TCD... No need FID... H 2, Air ECD... N 2 (In the case of a packed column, carrier gas is surely N 2. In the case of a capillary column, N 2 is used for makeup gas. ) FTD... H 2, Air FPD... H 2, Air BID... He Carrier Gas and Detector Gas

8 Pressure Problems High PressureLow Pressure Erratic or Cycling Pressure

9 Column Pressure 1.Column Length 2.Inner diameter 3.Packing size High Pressure FiltersFilters 1 BuffersBuffers 2

10 L OW P RESSURE Low Flow ResistanceLow Flow Resistance 1 Low Flow RateLow Flow Rate 2 LeakageLeakage 3

11 Erratic or Cycling Pressure Low Flow ResistanceLow Flow Resistance 1 APC, AFC MalfunctionAPC, AFC Malfunction 2 Bad ConditionBad Condition 3

12 Leaks Leaks Location the source Piping Column Fitting Leaks

13 Column Fitting Leaks

14 P IPING Piston Seal Tube Fitting Check Valve

15 Location the source

16 Component Malfunctions Electronic Problems Injector Problems Column Problems Temperatu re Problem Detector Problem s Flow Problem

17 With today's complex digital systems. Repairing electronic malfunctions usually requires an expert. But we provides suggestions for things that can be done before calling in an expert. Electronic Problem Fans Fuses Cables Boards

18 Detector Problems Contamination 1 Gas Purity 2 Leaks 4

19 Injector Problems Carryover-Manual Injector 1 Septum Condition 2 Glass Insert Contamination 3 Purge 4 Leaks 5

20 Column Problems Repairs Storage Cleaning Connation

21 B ASELINE P ROBLEMS Noisy Baselines 1.AFC 2.Gradient Temperature 3.Detector 4.Recorder 5.Data System Drifting or Cycling Baseline 1.Equilibration 2.Late Peaks 3.Temperature 4.Electrical

22 P EAK P ROBLEMS No Peak or Small PeaksNo Peak or Small PeaksNo Peak or Small PeaksNo Peak or Small Peaks1 Bad Peak ShapeBad Peak ShapeBad Peak ShapeBad Peak Shape2 Extra PeakExtra PeakExtra PeakExtra Peak3 Negative PeakNegative PeakNegative PeakNegative Peak4 Incorrect Retention TimeIncorrect Retention TimeIncorrect Retention TimeIncorrect Retention Time5 Poor ResolutionPoor ResolutionPoor ResolutionPoor Resolution6

23 B AD P EAK S HAPE Overload Sample Solvent Bad Columns Dead Volume

24 E XTRA P EAKS Late Peaks Carryover Peaks Ghost Peaks

25 N EGATIVE P EAKS

26 U NCORRECTED RETENTION TIME The Column The Eluent Temperature Equilibration

27 P OOR R ESOLUTION Theory Efficiency N Selectivity Retention K

28 PARTO ZIST BEHBOUD Web: www.Partoz.com Contact: INFO@PARTOZ.COMINFO@PARTOZ.COM Tel: 88104115 Fax: 88104117


Download ppt "TROBLESHOOTING GAS CHROMATOGRAPHY (GC) Parto Zist Behboud Reza Daj 8/16/2014."