Presentation is loading. Please wait.

Presentation is loading. Please wait.

KSA 16th of March. UPSUPS (Uninterruptible Power Supply) is a device which supply energy without interruptions to other electric devices. It uses batteries.

Similar presentations


Presentation on theme: "KSA 16th of March. UPSUPS (Uninterruptible Power Supply) is a device which supply energy without interruptions to other electric devices. It uses batteries."— Presentation transcript:

1 KSA 16th of March

2 UPSUPS (Uninterruptible Power Supply) is a device which supply energy without interruptions to other electric devices. It uses batteries to guarantee safe and good energy also in case of black out. It is not only an accessory but an important element of the system What is a UPS ?

3 On the Market there are three foundamental typologies of UPS On line Double Conversion Line Interactive Off Line Other names such as “Digital On-line”, “Semi-Online”, “Eco-Line” etc. are an attractive way to indicate Line Intteractive or Off Line UPS How to choose ?

4 OFF LINE In Out Filter circuit Inverter Batteries Battery charger switch Legrand doesn’t provide this Obsolete technology. (still exist in very low cost) Battery life is greatly reduced due to constant switching. UPS Topology

5 LINE INTERACTIVE In Out Inverter Batteries Battery charger Stabilizer AVR switch Filter circuit Thanks to the stabilizer, the output is better quality, and the batteries are less solicitated. UPS Topology

6 ONLINE DOUBLE CONVERSION In Out Inverter Batteries Converter Bypass The switchover is instant since the load is always supplied from the inverter. UPS Topology

7 Technologies available OFF LINE LINE INTERACTIVE ON LINE Wave Shape Switching time T = 3÷5 ms T = NO Time T = 3÷5 ms UPS MAINS VOLTAGE UPS MAINS VOLTAGE TOTALLY REGENERATED WAVE UPS MAINS VOLTAGESTABILIZED MAINS VOLTAGE

8 Applications for Line Interactive

9 Applications for Online Double conversion

10 UPS Basic parameters Nominal Power (VA) ; Active Power (W) ; Power Factor(PF) = Active power (W) / Nominal (VA); Autonomy; Input and Output Electric Specifications.

11 UPS Datasheet Power Factor= W/VA Technology Performance

12 UPS Datasheet Dimensions & Weight vs Autonomy

13

14 A new supplier in UPS world LEGRAND UPS UPS: another important brick in Legrand offer for commercial buildings - with an eye to business continuity - and another to efficiency and carbon footprint

15 Similar Business Models : Power, VDI, UPS

16 ENERGY EFFICIENCY UPS UNINTERRUPTIBLE POWER SYSTEMS

17 THE RANGE UPS Up to 120 kVA Solution for any applications MODULAR Up to 10 kVA CONVENTIONAL Up to 3 kVA LINE INTERACTIVE ACCESSORIES CONNECTIVITIES

18 UPS LINE INTERACTIVE  simple  reliable  economical

19 Niky The ideal protection for SOHO market.  The best ratio quality / price for the security of data, for your office and your home PC.  Ensure optimal management of protection.  Equipped with CPU control, AVR integrated and intelligent communications interface, ensuring optimal protection Line interactive Niky S

20 Niky  Advanced management of battery discharge  AVR  Built-in self test  Cold start function  Intelligent control of the microprocessor  RS232 or USB interface for UPS management  Telephone protection MODEM / LAN Niky S  Sinusoidal output  Intelligent microprocessor control  Telephone protection MODEM / LAN  RS-232 and USB interface for UPS management  Cold start function  Protection against voltage surges  Auto-test of the UPS  Smart battery management  Overload and short circuit protection  Possibility of adjusting the voltage

21 Niky packaging – Retail ready

22 UPS CONVENTIONAL  reliable  powerful  technology

23 Daker DK UPS on line double conversion Available in tower and rack versions. Rotative display from which its possible to monitor all the information and status of the UPS (batteries and charging status,events and alarms) CONVENTIONAL SINGLE PHASE Additional battery cabinets additional battery chargers availability.

24 Three standard units with power up to 10kVA Additional battery cabinets availability.Dimensions are from 2U to 4U: UPS and battery cabinet 2 U UPS and battery cabinet 3 U UPS and battery cabinet 4 U Daker DK

25 WHAD UPS on line double conversion for small and middle applications -available from 800 VA to 6000 VA -Small footprint -Models up to 2500 VA can have additional battery cabinete for longer autonomy -slot for SNMP card available on high end versions. CONVENTIONAL SINGLE PHASE

26 DHEA One UPS on line double conversion stack up design Composed by: -Inverter box -battery module -PLUG-IN connection - hot swap CONVENTIONAL SINGLE PHASE Small foot print with depth of 185 mm, can be positioned anywhere. ENRGY STATION

27 UPS MODULAR  versatility  espandable  redundant

28 MEGALINE  SINGLE CABINET  DUAL CABINET  RACK 19inch Modular UPS Redundant and expandable up to 10kVA Available in three versions: MODULAR SINGLE PHASE All the versions have the following: -Control board with microprocessor which can be configured via the display -Power module of 1250VA -Battery kit (3 batteries 9 Ah)

29 ARCHIMOD and TRIMOD  Granularity of the power THREE PHASE DYNAMIC SYSTEMS Single phase power modules redundant and self configurable  Optimisation of operations reduced size and weight Product Differentiation Excellence award 2011 Archimod and Trimod awarded by Frost & Sullivan :

30 Models: 20 kVA 40 kVA 60 kVA 80 kVA 100 kVA 120 kVA Adaptability Scalability Redundant Easy management Easy and quick maintenance High performances (low losses, small foot print) Archimod improves reliability and performances with: Redundant Communication Hot Swap function ARCHIMOD

31 ARCHIMOD Foot Print : Advantages:  Big power in a little space  Adaptable in any situation  Modular rack cabinet easy to install In only 0,52 square meters ARCHIMOD can protect until 120kva(108kw) of load.

32 TRIMOD Trimod From 10 to 60 kVA Modularity  Adaptable  Configurable  Power Scalable  Power Redundant  Back-up extensible

33 TRIMOD Foot Print : In only 0,25 square meters TRIMOD can protect until 60kva(54kw) of load. Advantages:  Big power in a little space  Adaptable in any situation  Modular rack cabinet easy to install

34 20 – 40 kVA Models can be configured, on site, as  3/3  3/1  1/1  1/3 4 UPS in 1 One UPS in stock - Four available applications Changes in Electric system doesn’t require changing the UPS Changing of the nature of the load doesn’t require changing the UPS Three-phase available inside single-phase systems Distribution Module

35 20min Three Independent Single Phases Three single phase output to be managed independently Black Out 5min 0 min

36 Ease of maintenance Small modules allow easy replacement Hot swap means that the load is always protected Maintenance costs can be lowered by 30% compared to conventional systems Only 8kg ! Just a Screwdriver

37 Scalability to adapt to the growing needs To allow growth, a conventional system need to be either oversized, or to have a future addition of an identical UPS alongside the existing one. This requires space and modification of the electrical cabling. A modular UPS allows for growth by simple addition of power modules. This can greatly lower the initial investment, as well as the future costs of changes

38 Efficiency because of optimal conditions High and constant Efficiency Standard UPS ARCHIMOD UPS A UPS is always more efficient near 90% load. When working a half capacity, a traditional UPS can waste up to 50% of the energy. By using a modular solution, it is possible to always function at the optimum load while allowing for growth. Furthermore, the Trimod and Archimod are designed for best efficiency, further reducing losses.

39 Conventional non modular UPS’ impose higher costs for redundancy. Example for a 40KVA load Redundancy N+1 45KVA UPS 40KVA Load Conventional UPS, working at 90% load. In case of UPS failure, the load is no longer protected 2x45KVA UPS 2x20KVA load To supply redundancy, the UPS needs to be doubled, significantly increasing the costs, and significantly reducing the efficiency of the UPS now working at 45% load. 45KVA UPS 40KVA Load But a modular UPS provides the redundancy per module, allowing lower costs, and best efficiency. It provides the best of both worlds: redundancy and efficiency.

40 Modular Traditional UPS The Modular UPS are higher density, and with N+1 redundancy, require less space. This can allow re-allocation of this space for other services. Reduced footprint

41 Conclusion: The modular systems provide a lower Total Cost of Ownership than conventional systems, allowing up to 30% saving over an 8-year period. Total Cost of Ownership

42 Why modular UPS? Energy savings Money savings

43 ACCESSORIES CONNECTIVITY Sistems for management and monitoring UPS

44 ACCESSORIES  NETWORK INTERFACE CONNECTIVITY with 32-bit processor and proprietary operating system that can continuously monitor the UPS and manage multiple events  SENSORS AND ACCESSORIES Temperature sensors, combined temperature and humidity sensors, Sensor Manager for environmental sensors, door sensors, flashing light signals. External version Internal version

45 ACCESSORIES  LOADS MANAGEMENT BOX (SITESWITCH) CONNECTIVITY Device for controlling the distribution of the energy, it can turn off individual devices connected to its four with the four independent power outputs.  SOFTWARE management and communication of UPS’s

46 UPS 46 MARKETING TOOLS

47 Communication toolbox LEGRAND TECHNICAL GUIDE Frost and Sullivan Award ADVERTISING FOR MEDIA/WEB UPS LEGRAND CATALOGUE

48 Communication toolbox

49 A tool to choose the best UPS according your needs Available : -Offline, downloaded on the website - In the Legrand softwares Xlpro3 Calcul / Tisystem DIGITAL COMMUNICATION TOOLS Configurator


Download ppt "KSA 16th of March. UPSUPS (Uninterruptible Power Supply) is a device which supply energy without interruptions to other electric devices. It uses batteries."

Similar presentations


Ads by Google