Zones 1 to 8 Siren Keypad Power 12V Data and clock By default: Zone 1 Entry Exit 2 Follower 3 Instant 4 Instant 5 Instant 6 Instant 7 Instant 8 Panic.

Similar presentations


Presentation on theme: "Zones 1 to 8 Siren Keypad Power 12V Data and clock By default: Zone 1 Entry Exit 2 Follower 3 Instant 4 Instant 5 Instant 6 Instant 7 Instant 8 Panic."— Presentation transcript:

1

2 Zones 1 to 8 Siren Keypad Power 12V Data and clock By default: Zone 1 Entry Exit 2 Follower 3 Instant 4 Instant 5 Instant 6 Instant 7 Instant 8 Panic Outputs1 to 5 By default: Output 1 Panic 2 Burglary 3 Open Closed Removable dialler 16 Volts AC Aux. Power Positve12V

3 Star Key Enter key for Data Input Hash Key Cancel, Backspace or Exit key

4 Ready LED Will flash when in programming mode Away LED Indicates if a location has been entered and a value can be programmed

5

6 How to read the values in a location Value 1 2 8 4 Each zone indicator is given a value 16 32 64 128

7 How to read the values in a location Example: 1 4 + Value in the location is 5 Each zone indicator is given a value To get the value in that location add the zone values together of any zones that are on

8 Press the # key to clear any previous key presses The default installer code is 9999 The ready LED will begin to flash indicating that programming mode has been entered How to enter into programming mode

9 All data that is entered must be entered into location A location is a storage area in the alarm panel’s memory. Each location or memory area is linked to a specific task. What is a location? Example: Location 15 is linked to making the alarm silent Location 18 is linked to the exit delay period during the arm cycle

10 You must be in programming mode To enter a value: 1. Enter the location to be programmed (The away light will come on to show that you are in the location) 2. Once in the location enter the value of the data and confirm by pressing the * key Once the data has been entered you are removed from the location Entering a location to programme a value

11 Location 0 ValueAction 0 Resets all locations to the factory default values. 1 Defaults the master user code to 1234 2 Resets all reporting codes to 0 Defaulting

12 Location 1 to 8 Zone Characteristics ValueType 0 Disable 1 Entry / Exit 2 Follower 3Audible priority / Panic 4Audible Instant 5Arm / Disarm 6Silent Priority 7Silent Instant 8Secondary Entry / Exit 10Fire Zone 12Push to Arm

13 LocationDescriptionDefault Value 9Entry / exit options Entry/ exit zones must be clear | Follower zones must be clear | Entry/ exit delay enabled 9 (Entry / exit zones clear, delay enabled) 10Secondary Entry exit delay5 (1min) 11Tamper per zone0 (Disable) 12Arming options Quick Arm | Entry/ exit delay with arm zone | Forced arming | Engineer reset 1(Quick Arm) 13Stay Arm Options Entry exit not violated | Always away arm no 5 key | Always away arm with 5 key 0 (Entry exit not violated) 14Silent Keypad Panic Options0 (Audible) 15Silent Alarm Options0 (Audible) 16Siren Toot on Arm & Disarm0 (no toot) 17Siren Time Out Period6 (2min) 18Exit Delay Period3 (30sec) 19AC Fail & Restore Time1 (2min) 20Primary Entry Delay3 (30sec) 21Hardware rest Switch Enable / Disable15 (Enable)

14 Exercise: 1.Change zone 7 to be an arm / disarm zone 2.Make the exit delay 10 seconds 3.Set siren toot on arm and disarm 4.When arming the front door must be allowed to remain open

15 Programmable OutputProgram Value PulseSet HighSet Low Output 1 1611 Output 2 2712 Output 3 3813 Output 4 4914 Output 5 51015

16 LocationEventValue 22Alarm2 23, 26, 36Audible Panic, Duress, Silent Panic1 28Open8 29close13 22 to 41Output locations 158 - 165Zone programmable output Control0 166 - 170Tamper output control

17 Exercise: 1.When the medical condition is triggered output 4 must pulse 2.Set output 5 to the strobe output

18 Reporting via Telephone LocationDescriptionDefault 42 Phone number and dialling options Join numbers | Pulse or Tone dialling | Single or Dual reporting 1 No join | Tone | Single 43-46 Primary account code 47 Primary Communicator Format0 Secoa Superfast 48-63 Primary Telephone number 64 -79 Secondary Telephone number 151 Dial Attempts4 152-155 Secondary Account code 156 Secondary Communicator Format0 Secoa Superfast 157 Communication Delay0

19 Note when entering telephone numbers:  0 is programmed as a 10  * Is an 11  # is a 12  12 second pause is a 14  4 second pause is a 15  Terminate the number with a 0 (zero not a ten)

20 Reporting Codes Location 80 to 133 Contact Id and Sescoa Superfast are the only reporting codes that are inserted when chosen as a reporting format. The rest of the reporting codes must be manually entered To disable a reporting code enter a 0 If a reporting code requires a 0 the use 10

21 Exercise: 1.Enter 0(4 second pause) 0317050200 as the telephone number 2.Account code of 1023 Reporting format is Contact ID

22 LocationDescriptionDefault 136 - 139Installer code9999 140Swinger shutdown count0 141Zone loop Response100mS 142Zone Trip count0 143Zone Trip count delay timer0 144Programmable Trouble Display Display of TLM Fail | Display of Siren Tamper 3 Display both 145Programmable Trouble Display 2 Display of Comms. Fail | Display of Keypad Tamper | Display of Eng. Reset 7 146Keypad sleep delay128 sec 147Auto test delay24 Hrs

23 LocationDescriptionDefault 148Number of rings before answer24 Hrs 149Keypad buzzer options Beep on communication | Beep on trouble | Beep on both 15 150Enable siren, telephone line, box tamper monitoring2 Beep on communication 800System time 801Auto-test time 802Auto Arm Time

24 A trouble condition is indicated by a flashing power light Press and hold the 7 key for 3 seconds ZoneTrouble Condition 2 Failure to communicate to monitoring Company 3 Mains power fail 4 Low Battery 5 Telephone line tamper or not present 6 Siren tamper 7 Keypad tamper 8 Engineer reset required

25

26 Ready LED Shows that the alarm is ready to arm Away LED Indicates that the alarm has armed in the away mode Armed LED Shows that the alarm is armed Power LED On means there is power Flashing shows that there is a trouble condition

27 3 Arming options Away arming In this mode the alarm is fully armed, all zones are active. The delay on the entry exit zones will be active Stay arming Zones that have been preselected will be automatically bypassed to allow people to move around without activating the alarm Stay and Go arming Zones that have been preselected will be automatically bypassed The delay on the entry exit zones will be active

28 2 options in how to arm in the away mode Enter a user code and when the exit beeps begin, exit through an entry / exit zone Press and hold the 1 key for 3 seconds and when the exit beeps begin exit through an entry / exit zone Note: Failure to exit via a entry / exit zone will force the panel to arm in the stay arm mode in the default configuration.

29 Press and hold the 5 key until armed LED is on The zones that were selected as stay zones will be bypassed and these zones will be shown on the keypad

30 To select zones to be bypassed in the stay mode Press and hold 3 until the buzzer sounds Then press the zone number then * Do this for all zones required When complete press #

31 2 Stay profiles Two different zone groupings to be bypassed can be created To change profiles Mode + 9 + profile number + * Note: the second profile’s zones to be bypassed must be selected as before

32 The best of both away and stay arming In this mode all entry / exit zones are active and the zones selected in the Stay profile will be bypassed Note: the active stay profile is used to determine which zones to bypass

33 Disarming A valid user code must be entered Or A remote Transmitter and Receiver can be used

34 Press star then the zone number to be bypassed or un-bypassed

35 Alarm memory To see what zones were violated Press and hold the 0 key until the buzzer sounds Zone bypassed Memory To see which zones were bypassed Press and hold the 0 key until the buzzer sounds then press 1 Zone Tamper Memory To see what zones have been tampered with Press and hold the 0 key until the buzzer sounds then press 2 Memory is cleared when the panel is armed

36 15 user codes made up of the following: 12 x standard user codes (arm and disarm) 1 x Master User ( Slot 1 Administrator ) 1 x Maids Code ( Slot 14 Will only disarm if it was used to arm ) 1 x Duress ( Slot 15 Will arm or disarm and send a panic signal )

37 * Master code * slot number * new code * Eg. * 1234 * 4 * 5647* Deleting a user code * Master code * slot number * * Eg. * 1234 * 5**

38 Chime Zones The keypad will chime when a zone that has been made a chime zone is violated in the unarmed state Press and hold 2 until buzzer sounds then zone number then * Buzz Zones The keypad will buzz for 30 seconds when a zone that has been made a buzz zone is violated in the stay armed state Press and hold 4 until buzzer sounds then zone number then *

39 Zone Indicator Trouble Condition 2Failure to communicate to monitoring Company 3Mains power fail 4Low Battery 5Telephone line tamper or not present 6Siren tamper 7Keypad tamper 8Engineer reset required Press and hold 7 until buzzer sounds Press # within 5 seconds to clear the condition Some conditions will clear automatically when fixed