Presentation is loading. Please wait.

Presentation is loading. Please wait.

Bulatom Confernce June 2007

Similar presentations


Presentation on theme: "Bulatom Confernce June 2007"— Presentation transcript:

1 Bulatom Confernce 06-08 June 2007
Evaluation of the flow mixing in VVER-1000 downcomer under natural circulation. V. Lefterov, E. Popov Atoma Consult Ltd Bulatom Conference May 2008 Atoma Consult Ltd

2 Reasons for fluid mixing evaluation in a reactor downcomer:
Bulatom Confernce June 2007 Reasons for fluid mixing evaluation in a reactor downcomer: risk of over-criticality in a local volume of the reactor core by low boron concentration risk of over-criticality in a local volume of the reactor core by low coolant temperature risk of local pressurized thermal shock (PTS) on the reactor vessel wall Bulatom Conference May 2008 Atoma Consult Ltd

3 Evaluation of flow mixing – How to?
Bulatom Confernce June 2007 Evaluation of flow mixing – How to? large scale transparent model experiments large scale model experiments, using a lot of sensors in the facility Residence Time Distribution (RTD) method three dimensional computational fluid dynamics (CFD) calculations. Bulatom Conference May 2008 Atoma Consult Ltd

4 CFD model – developed by Atoma Consult Ltd
Bulatom Confernce June 2007 CFD model – developed by Atoma Consult Ltd Two mutually independent components: Mesh – represents the geometrical characteristics of the investigated volume; Solver – implements the mathematical apparatus, applied in the analysis. Bulatom Conference May 2008 Atoma Consult Ltd

5 Investigated scenario
Bulatom Confernce June 2007 Investigated scenario Boundary conditions – Main Steam Line Break (MSLB) on loop 2 Calculations with RELAP5/mod3.3; Conservative initial and boundary conditions; Sensitivity study – failure of EFW and FAIV; Results: FAIV failure creates larger temperature difference (80 oC). Bulatom Conference May 2008 Atoma Consult Ltd

6 Initial and boundary conditions
Bulatom Confernce June 2007 Initial and boundary conditions Table I – Initial and boundary conditions for the CFD calculations Bulatom Conference May 2008 Atoma Consult Ltd

7 Bulatom Confernce 06-08 June 2007
Calculation results I Figure I – Velocity distribution Bulatom Conference May 2008 Atoma Consult Ltd

8 Calculation results II
Bulatom Confernce June 2007 Calculation results II Figure II – Velocity stream lines Bulatom Conference May 2008 Atoma Consult Ltd

9 Calculation results III
Bulatom Confernce June 2007 Calculation results III Figure III – Temperature distribution in the downcomer and the core inlet Bulatom Conference May 2008 Atoma Consult Ltd

10 Calculation results IV
Figure IV– Loop 2 flow mixing in the downcomer and the core inlet Bulatom Conference May 2008 Atoma Consult Ltd

11 Calculation results IV
Bulatom Confernce June 2007 Calculation results IV Figure V – “Cold spot” rotation in the core inlet Bulatom Conference May 2008 Atoma Consult Ltd

12 Bulatom Confernce 06-08 June 2007
Sensitivity study Table II – Loop inlet velocities for the sensitivity study Bulatom Conference May 2008 Atoma Consult Ltd

13 Sensitivity study – results I
Bulatom Confernce June 2007 Sensitivity study – results I Figure VI – “Cold spot” rotation in the core inlet for the high velocity case Bulatom Conference May 2008 Atoma Consult Ltd

14 Sensitivity study – results II
Bulatom Confernce June 2007 Sensitivity study – results II Figure VII – “Cold spot” rotation in the core inlet for the medium velocity case Bulatom Conference May 2008 Atoma Consult Ltd

15 Sensitivity study – results III
Bulatom Confernce June 2007 Sensitivity study – results III Figure VIII – “Cold spot” rotation in the core inlet for the forced circulation case Bulatom Conference May 2008 Atoma Consult Ltd

16 Sensitivity study – summary
Bulatom Confernce June 2007 Sensitivity study – summary Table III – Summary on the sensitivity study results Bulatom Conference May 2008 Atoma Consult Ltd

17 Bulatom Confernce 06-08 June 2007
Conclusions Selected scenario – MSLB on VVER-1000 Boundary conditions – RELAP5/mod3.3; Flow mixing and rotation – CFD calculations; Applied software and models are adequately verified and validated; Results: Relatively small core inlet area (~5%) from the quarter fed by the broken loop inlet is with very low ( %) mixing coefficient; The flow rotation is independent of the velocities magnitudes at constant “intact/damaged” loops velocity ratio; The flow rotation depends strongly on the “intact/damaged” loops velocity ratio; Results can be finally validated against large scale model experiments. Bulatom Conference May 2008 Atoma Consult Ltd