Only for Loneworkers. People who work alone (day- or nightshifts, or self-employment) are initially on their own in the case of an emergency. That is.

Similar presentations


Presentation on theme: "Only for Loneworkers. People who work alone (day- or nightshifts, or self-employment) are initially on their own in the case of an emergency. That is."— Presentation transcript:

1 Only for Loneworkers

2 People who work alone (day- or nightshifts, or self-employment) are initially on their own in the case of an emergency. That is why the safety of lone workers requires extra attention. A lone worker is someone who works out of sight or earshot of other people. Only for Loneworkers

3 My Bodyguard has developed a lone workers concept. The concept links a request for help to a safety worker. The request for help can be triggered manually by pressing just one or two buttons. However, if the user is no longer capable of doing a manual request, for instance while being unconscious, a request for help can also be activated automatically if insufficient motion is detected. This concept is called "man down". Only for Loneworkers

4 My-Bodyguard Technical Specification: Size 84x75x32 mm. Size 84x75x32 mm. Weight 165 g. Weight 165 g. Operating time 24 hour. Operating time 24 hour. IP Code 54 dustproof and splash proof IP Code 54 dustproof and splash proof GPS 20 channel receiver. GPS 20 channel receiver. GSM dual band 900/1800 Mhz. GSM dual band 900/1800 Mhz. 2.4 Ghz transmitter / receiver ZigBit. 2.4 Ghz transmitter / receiver ZigBit. On order EX approved. On order EX approved. The Technique

5 GSM Network outside buildings My-Bodyguard uses the GSM network to send emergency calls.My-Bodyguard uses the GSM network to send emergency calls. It is important that at all locations outside, where employees areIt is important that at all locations outside, where employees are working there is GSM coverage. The technique

6 GSM Network indoor It is also important that there is good GSM network present insideIt is also important that there is good GSM network present inside buildings. If not present an offer can be made for GSM repeaters insideIf not present an offer can be made for GSM repeaters insidebuildings. If the loneworker is in areas where GSM coverage is not present, in an excess of a preset time it will be reported as alarms.If the loneworker is in areas where GSM coverage is not present, in an excess of a preset time it will be reported as alarms. The technique

7 There is an important role for a good functioning central alarm service. They are leading to ensure that the request for help with all important information is send to the helpers in the field. Central Alarm Service

8 Reports may be transmitted in various ways to the helpers in the field. Calling multiple helpers.Calling multiple helpers. First send an SMS/E-Mail and then call the helpers for check.First send an SMS/E-Mail and then call the helpers for check. There may be a link between your alarmpost an the Central Alarm Service as an annex (software required).There may be a link between your alarmpost an the Central Alarm Service as an annex (software required). Central Alarm Service

9 To the alarm service central it is essential that the correct information is send as quickly as possible to the helpers. Outside buildings the position of the loneworkers is calculated by the use of GPS. For enclosed areas, within fences, addresses of standard maps are not good to use, the right addresses should be separately added to our database. Central Alarm Service

10 The yellow shaded area is the business address ´Het Wegdam 1´. When you position at the green arrow in Google Maps the address returned is ´Het Assink 8´ which is the location at the red balloon.

11 If we add the location to our database we also add specific information about the location. The red balloon is the container storage. When an alarm is raised inside this area this information is also shown to the operator. The operator will see the following: Het Wegdam 1, 7496 Hengevelde, NL – Container Storage

12 GPS doesn’t work inside buildings. Therefore measures must be made in the case loneworkers are working in buildings. There are 5 different ways to do this: Central Alarm Service

13 1. You can us socalled Ibuttons in combination with an Ibuttonreader. The loneworker has to report where he works for every room with the IButton, then in case of an emergency the location of the last IButton read will be reported to the Central Alarm Service. Central Alarm Service

14 2.Data is provided showing all addresses and locations where the worker may be located in an emergency. This solution is widely used in e.g. the nursing staff. Central Alarm Service

15 3.You use beacons that automatically register in what room and on which floor the loneworker is in the case of an emergency. Central Alarm Service

16 4. A connection is made with the persons agenda. If the agenda is kept up to date this can be used to determine the location of the person. The location and time of the current agenda point is shown to the operator and passed on to the emergency services. Central Alarm Service

17 5. An application can be installed on a phone with Android or an iPhone. With this application you can select or type your current location. Also the time you are at the site is filled in. For example: Now (8:20) until 9:30. This location with time is shown to the operator during an alarm and also passed on the the emergency services. Central Alarm Service

18 The loneworkers can send various request for help, depending on the urgency. The report with the highest urgency in activated by pressing both the red and the green button. There are multiple ways of arranging how to react: PolicePolice AmbulanceAmbulance Fire departmentFire department Corporate safety serviceCorporate safety service Own securityOwn security ColleaguesColleagues Central Alarm Service

19 Lower emergency reports are activated by pressing only the red button. Lower emergency reports are cases like for example: being stuck in a room. There are multiple ways of arranging how to react: Corporate safety serviceCorporate safety service Own securityOwn security ColleaguesColleagues Central Alarm Service

20 The report by insufficient movement “man down”. Man Down means that a loneworker is not capable of pressing the button to sound the alarm himself. There are multiple ways of arranging how to react : Corporate safety serviceCorporate safety service Own securityOwn security ColleaguesColleagues First user then colleagesFirst user then colleages Central Alarm Service

21 For a well working concept the it has to be properly organized on a organizational level. The support of the end-user (loneworker) is very important. Organizational

22 For the right use proper explanation is required. Organizational

23 It is important that the complete concept is checked on proper use and functioning. A report will be send the person responsible for guiding the people about the theme working alone. Organizational

24 Within 7 days after shipment you need to make an alarm with the red button on the My-Bodyguard. Before you do anything read the instruction manual thoroughly. In case the alarm is not made within 7 days you will be called with the request to make the alarm. Warning: You are not connected to the alarm service central until this alarm has come through correctly. First Alarm

25

26 De gebruiker moet gebeld worden met het verzoek om zich te melden door het indrukken van de Rode knop. First Alarm

27 The user needs to press the button until the My-Bodyguard vibrates long. The light on the backside will then burn red. You get a voice connection and can talk to the user. “Red button pressed, New unit report with old position" First Alarm

28

29 The My-Bodyguard needs to go outside for a proper GPS position. Give the user, through the My-Bodyguard, the instructions to to this. After this the use doesn’t have to do anything, the My-Bodyguard will automatically report with the correct GPS position. “New position r, New unit report ok" First Alarm

30

31 The user needs to be called. He will be notified that the report came in correctly and he is now connected to the ASC. First Alarm

32 You will not get a voice connection and can’t talk to the dispatcher. He can’t do this until the connection with the alarm service central is gone. The light on the My-Bodyguard should be blinking green again before you do this. First Alarm

33

34 Afterwards the map in the TrackViewer needs to be closed. First Alarm

35 If the first alarm of the My-Bodyguard has a correct position you will get the following notice: “Red button pressed, New unit report ok" “Red button pressed, New unit report ok" First Alarm

36

37 The user can be welcomed. He will be notified that the report came in correctly and he is now connected to the ASC. First Alarm

38 Afterwards the map in the TrackViewer needs to be closed.

39 Alarm with the highest urgency by pressing the Red and Green button. The user has to press the buttons until the My-Bodyguard vibrates long. The light on the front will now glow red. You get a voice connection and can talk to the user. “Both buttons pressed" Highest Urgency Alarm

40

41 It is important that the position of the unit is current. It is always shown how long ago the last position came in. This time will change in color depending on how long ago the position came in. A current position is green it will then change to yellow, orange and finally to red. Highest Urgency Alarm

42 For more detail you can zoom in and out and you can move the map with the arrows. Highest Urgency Alarm

43

44 Further more all positions of the last hour will be displayed when the alarm comes on the screen. For more information click on View and then Positions and you will get a complete overview of the last hour. Highest Urgency Alarm

45

46 In case the user moves or the send location wasn’t correct the My- Bodyguard will renew the alarm. You will get a voice connection and can talk to the user. “New position rg" Highest Urgency Alarm

47

48 Afterwards the map in the TrackViewer needs to be closed.

49

50 Alarm with a lower urgency by pressing the Red button. The user has to press the button until the My-Bodyguard vibrates long. The light on the front will now glow red. You get a voice connection and can talk to the user. “Red button pressed" Lower Urgency Alarm

51

52 In case beacons are placed on the site the user is those will be used to determine the location. Further more the level (floor) the user is on will be displayed. At the status it will show “Indoor position”. Lower Urgency Alarm

53

54 If the person moves or the location send was incorrect the new position will be send to the Alarm service central. The extra information about the location is important for the rescuer on site and will have to be relayed without fail. Lower Urgency Alarm

55 Afterwards the map in the TrackViewer needs to be closed.

56

57 - Alarm by not moving enough. - The My-Bodyguard will automatically make an alarm if it hasn’t moved - enough for 5 minutes. The user will be warned by a pre-alarm. - In case the user doesn’t press on one of the buttons within 30 seconds the alarm will be transmitted to the alarm service central. - You get a voice connection and can talk the user. - “Non Movement" Not enough movement alarm “ Man down”

58

59 Afterwards the map in the TrackViewer needs to be closed.

60

61 Conclusion: The dispatcher at the alarm service central is the eyes for the rescuer on site. With as much, correct, information as possible the rescuer should be able to help the victim as good as possible. Not enough movement alarm “ Man down”

62 After assistance has been given or the test is completed, the user has to log off by pressing the Green Button. Recover / Test Alarm Press for a minimum of 3 seconds on the Green Button. Keep pressing until the unit vibrates long.