Presentation is loading. Please wait.

Presentation is loading. Please wait.

1 Database for Energy Efficiency Resource User Demonstration Jennifer Barnes Pacific Energy Center October 11, 2005.

Similar presentations


Presentation on theme: "1 Database for Energy Efficiency Resource User Demonstration Jennifer Barnes Pacific Energy Center October 11, 2005."— Presentation transcript:

1 1 Database for Energy Efficiency Resource User Demonstration Jennifer Barnes Pacific Energy Center October 11, 2005

2 2 What is DEER?  A collection of data for Residential and Non-Residential energy efficiency measures.  http://eega.cpuc.ca.gov/deer/  It provides a common set of: Ex ante Savings values: kW, kWh, kBtu Measure Costs Effective Measure Life (a.k.a EUL)

3 3 Website Navigation  Measures categorized by Residential and non-residential Weather sensitive and non-weather sensitive Non-weather sensitive measure impacts determined through engineering calculations Savings do not vary by climate zone or vintage, only building type

4 4 Weather sensitive measures Weather sensitive measure impacts simulated using DOE2/eQUEST Single family, multifamily, mobile homes, and 22 non- residential building types Five building vintages 16 climate zones Two levels of savings Customer savings - for system savings and early replacement savings. “Above Code” Savings - for all measures affected by an energy code or standard (reportable savings for replace on burnout)

5 5 Common Units  Describes the normalizing unit Per ton, lamp, household, linear feet, cloths dryer, etc. The energy and cost common units are distinct Over 90% of cases, they are the same When different, distinctly identified

6 6 Measure Costs  Application – indicates if the cost is for: Retrofit (RET) - replacing a working system with a new technology or adding a technology Replace-on-burnout (ROB) - replacing a technology at the end of its useful life New construction or major renovation (NEW) - installing a technology in a new construction or major renovation  Cost Basis – indicates if the cost is: Incremental (INCR) - the differential cost between a base technology and an energy efficient technology Installed (FULL) - the full or installed cost of the measure including equipment, labor, overhead & profit (OH&P)

7 7 Notable Changes  Eliminated coin-operated high efficiency clothes washers and hot water heater tank wrap  T-12 removed from DEER as a base case because of new federal guidelines. However, it may be legitimate in lamp/ballast (only) change outs.  Programmable thermostats savings diminished:  Change in residential assumptions  Programmable thermostats or time clocks required by code since 1992 A/C savings reduced due to stricter code requirements

8 8 CFL Changes Integral versus modular Modular – hardwired ballast with replaceable lamp. 16 year life (res.) Integral – lamp and ballast are “fused.” 9.4 year life (res.) In service factor – applied to CFLs to account for units not in operation Non-res. CLF – “SPC” – assumes that all units are installed and operational Non-res. CFL – in service factor of.92 Residential CFL – in service factor of.9 No in service factor for table lamps and torchieres

9 9 Website Navigation – Opening Screen

10 10 Website Navigation – Browse Measures

11 11 Website Navigation – Select Subcategory

12 12 Website Navigation – Review Summary Page - Top

13 13 Run ID String variable of fixed length of 13 with the format: ABBB1122CCCCC where: A = Sector Code. ‘R’ = Residential and ‘C’ = Commercial BBB = Building type abbreviation (see codes under Building Type) 11 = Climate zone (see codes under Climate Zone) 22 = Vintage (see codes under Vintage) CCCCC = Measure abbreviation Measure ID - String variable of fixed length of 7 (example: D03-001)

14 14 Website Navigation – Review Summary Page - Bottom

15 15 Website Navigation – Detailed Measure Information

16 16 Website Navigation – Detailed Measure information - Top

17 17 Website Navigation – Detailed Measure information - Bottom

18 18 Supporting Documents Section  Website Users Guide  Net-to-Gross Ratios Table (Use.8 if in doubt)  Access Tables  Glossary  Cost Data  Cost Data User’s Guide  New EUL Estimates 7-14-05 (SERA Report)  Consolidated Measure Data

19 19 Supporting Documents Section – Consolidated Measure Data

20 20 Questions/Comments?

21 21 DEER Measure Cost Detail

22 22 Defining Cost Parameters Measure Cost Specifications (Cont.)  Cost data is first cost only -- life cycle or O&M costs/cost savings not included  Pricing reflects commonly available “standard” products and excludes specialty, high-end items  Some price observations (outliers) were excluded to assume a rational purchasing policy would be used (“who would pay THAT?”)  Equipment and labor prices are specific to California to extent possible but average across state

23 23 Defining Cost Parameters Key Cost Definitions  Cost Observation – a single price point for an individual measure or measure configuration Cost values are what a program participant would pay to implement the measure consistent with definitions in the CA Standard Practice Manual (initial capital cost)  Cost units ($ / ton, $ / HP, $ / square foot, etc.) Mostly the same although different for some measures Distinct field in detailed cost data; appended to Cost Basis designator in measure detail

24 24 Data Collection and Analysis Process Labor Cost Estimates  Labor cost estimates generally base on manhours required to complete task times appropriate wage rate  Wage rate based on trade (electrician, plumber, etc.) and geographic location of activity  RS Means used to provide wage rate and location adjustment multipliers

25 25 1. Website and on-site cost surveys of retailers 2. Cost quotes from manufacturers, manufacturers sales representatives, and distributors 3. Cost surveys of contractors and design professionals. 4. Cost data from in California DSM program files, particularly local programs 5. Secondary sources and reports Data Collection and Analysis Process Cost Data Sources

26 26 Data Collection and Analysis Process Cost Analysis Workbooks  Excel based cost analysis workbook developed for each measure.  Each workbook has 5 sections:

27 27 Data Collection and Analysis Process Cost Analysis Workbooks – Raw Data  Example of the ‘Raw Data’ section of the High Efficiency Electric Clothes Dryer workbook

28 28 Data Collection and Analysis Process Cost Analysis Workbooks – Cost Results  Example of the ‘Results’ section of the High Efficiency Electric Clothes Dryer workbook

29 29 Data Collection and Analysis Process Cost Analysis Workbooks – Statistical Summary  Example of the ‘Statistical Summary’ section of the High Efficiency Electric Clothes Dryer workbook

30 30  How to find the most applicable cost information? Measure detail pages for each run ID - the per unit equipment measure cost of $13.65 for all 90% residential furnaces This provides an average cost based on a 100,000 Btu furnace The ‘Cost Data’ file under ‘Supporting Documents’ provides prices on a range of furnace sizes This provides a range of costs for 90% AFUE furnaces from 60,000 Btu to 140,000 Btu. Per unit costs ($/KBtu) ranges from $21.53 to $12.13, respectively The cost workbook section – Can use either statistical summary or individual price observations For example, the per unit equipment measure cost for 90% AFUE 100,000 furnaces ranges from to $12.31 to $16.52 based on 9 observations Cost Data Defining Cost Parameters

31 31 DEER Non-weather Sensitive Measure Detail

32 32 Non-Weather Sensitive Measures Residential Measures  CFL Lighting  Refrigerators  Clothes Washers & Dryers  Dishwashers  Water Heating  Swimming Pool Pumps

33 33 Non-Weather Sensitive Measures Residential Measures  CFL Lighting Measure Impact = (delta watts/unit * hours/day * days/year * In Service Rate) / 1000 watts/kWh Demand Impact = delta watts/unit * In Service Rate * Peak Hour Load Share The “In Service Factor” is an estimate of the percentage of lamps that are actually used. It is a rough estimate based on utility experience. . 9 to be used for all residential CFL programs .92 to be used for non-residential rebate or giveaway programs  1.0 to be used for verified installation programs. Labeled “SPC” in measure name Hours of Operation/Day” and “Peak Hour Load Share” from KEMA CFL Metering Study

34 34 Non-Weather Sensitive Measures Residential Measures  CFL Lighting – Example (14W CFL replace 60W Inc) Measure Impact = (46W * 2.34 hours/day * 365 days/year * 0.9) / 1000 watts/kWh = 35.4 kWh Demand Impact = 46W * 0.9 * 0.081 = 3.35 W

35 35 Non-Weather Sensitive Measures Residential Measures  Refrigerators Used the Energy Star calculator available on-line at: http://www.energystar.gov Key Input values for the calculator: Refrigerator Type (top, side, or bottom mount freezer) Ice through the door (yes or no) Refrigerator fresh volume (cubic feet) Refrigerator freezer volume (cubic feet)

36 36 Non-Weather Sensitive Measures Residential Measures  Clothes Washers Utilized the three recommended Consortium for Energy Efficiency (CEE) Tiers for Modified Energy Factor: Used the Energy Star calculator (that utilizes an EF rather than MEF) on-line at: http://www.energystar.gov Estimated the equivalent EF value for CEE MEF values from Energy Star list of approved washers Other key Energy Star variables include: Number of wash cycles/year (E Star value is 392 cycles) Washer capacity (three sizes – 1.5, 2.65, and 3.5 cubic feet) Further disaggregated impacts by water heat and clothes dryer fuel types Fuel impact disagreegations based on ‘Efficiency Vermont” estimates Demand impact based on a energy/peak factor of 0.417. This is carryover from previous 2001 DEER http://www.energystar.gov

37 37 Non-Weather Sensitive Measures Residential Measures  Clothes Washer – Example (Tier 3 2.65 cu.ft) Measure Impact = (cycles/year * capacity / base EF) – (cycles/year * capacity / measure EF) = (392 * 2.65 / 1.58) – (392 * 2.65 / 4.94) = 447 kWh Demand Impact = Measure Impact * energy/peak factor = 447 kWh * 0.417 = 186.4 W

38 38 Non-Weather Sensitive Measures Residential Measures  Clothes Dryer 1993 National Appliance Energy Conservation Act (NAECA) minimum efficiency used for base technology: EF = 3.01 for electric dryers EF = 2.67 for gas dryers Used DOE test procedure guidelines for: Drying cycles per year = 416 UEC of 2.33 kWh/cycle for electric (969 kWh/year) UEC of 8.95 kBtu/cycle for gas (37.2 therms/year) Assumed 416 cycles represented Single Family Assumed 250 cycles for Multi-Family (CEC estimate of 60% less use by MF) Energy savings 5% of energy use. This is a carryover from previous 2001 DEER Demand impact based on a energy/peak factor of 0.371. This is carryover from previous 2001 DEER

39 39 Non-Weather Sensitive Measures Residential Measures  Clothes Dryer – Example (SF electric) Measure Impact = Electric base use * Savings Percentage = 969 kWh * 0.05 = 48 kWh Demand Impact = Measure Impact * energy/peak factor = 48 kWh * 0.371 = 17.8 W

40 40 Non-Weather Sensitive Measures Residential Measures  Dishwasher Used the Energy Star calculator available on-line at: http://www.energystar.gov Key Input values for the calculator: Base Energy Factor (EF) = 0.46 Measure Energy Factor = 0.58 Annual wash cycle (DOE test procedure) = 215 (assume SF) MF wash cycles (assumed to be ~75% of SF) = 160 Demand impact based on a energy/peak factor of 0.371. This is carryover from previous 2001 DEER

41 41 Non-Weather Sensitive Measures Residential Measures  Water Heating Measures: High efficiency water heater (electric EF=0.93, gas EF=0.63) Heat pump water heater (EF=2.9) Point of use water heater low flow showerhead (from 2.5 to 2.0 gallons per minute) Pipe wrap Faucet aerators  Note: Removed water heater blankets because they’re obsolete on models made after 1990. Savings expressed as % of base use Base use varied by utility service area (same method as 2001) Demand impact based on a energy/peak factor of 0.22. This is carryover from previous 2001 DEER

42 42 Non-Weather Sensitive Measures Residential Measures  Water Heating Measure Saving %: High efficiency water heater – electric - 5.4% High efficiency water heater – gas - 5.0% Heat pump water heater – 69.7% Point of use water heater – 15.0% low flow showerhead – 4.0% Pipe wrap – 4.0% Faucet aerators – 3.0%

43 43 Non-Weather Sensitive Measures Residential Measures  Pool Pumps Single speed and two speed included Relied on PG&E and SCE engineers for calculating impacts: General assumptions: Average pool size of 25,000 gallons Average water turnover rate of 6-8 hours Average pump motor demand of 1.75 kVA Typical filtration time of 4 to 6 hours For single speed motors, motor downsizing and runtime reductions assumed

44 44 Non-Weather Sensitive Measures Non-Residential Measures  Interior Lighting  Exterior Lighting  Cooking  Copy Machine  Water Heating  Vending Machine Controls  High Efficiency Motors  Agriculture

45 45 Non-Weather Sensitive Measures Non-Residential Measures  Interior Lighting Measures: CFL screw-in lamps CFL hardwire fixtures High intensity discharge (HID) lamps Premium T8 lamps Dimming Ballasts De-lamping fluorescent 4 ft and 8 ft fixtures  Note: T-12 removed from DEER as a base case because of new federal guidelines. However, it may be legitimate in lamp/ballast (only) change outs.

46 46 Non-Weather Sensitive Measures Non-Residential Measures  Interior Lighting – Basic Methodology Measure Impact = (delta watts/unit * hours/day * days/year * In Service Rate) / 1000 watts/kWh Demand Impact = delta watts/unit * In Service Rate * Peak Hour Load Share

47 47 Non-Weather Sensitive Measures Non-Residential Measures  Exterior Lighting & Exit Signs High intensity discharge (HID) lamps Exit Signs Timeclocks Photocells

48 48 Non-Weather Sensitive Measures Non-Residential Measures  Exterior Lighting & Exit Signs Methodology HID lamps : delta watts saved * hours of use (4,100 hours) no peak impacts Exit Signs : delta watts saved * 8760 hours * Interactive Effects peak = delta watts * Interactive effects * 1.0 (coincidence factor) Timeclocks & Photocells : watts controlled * hours of control no peak impacts

49 49 Non-Weather Sensitive Measures Non-Residential Measures  Cooking High efficiency fryers (gas & electric) High efficiency griddle (gas) Hot food holding cabinet Connectionless steamer

50 50 Non-Weather Sensitive Measures Non-Residential Measures Cooking - Methodology Relied primarily on the PG&E technology briefs For each of these measures, the energy savings calculation methodology is of the form: Savings = (APECRBase – APECREfficient) * Daily Hours * Days Where : APECR = The Average Production Energy Consumption Rate/hour Daily Hours = 12 Days = 365

51 51 Non-Weather Sensitive Measures Non-Residential Measures  Copy Machines – three sizes 0-20 copies/minute 21-44 copies/minute over 45 copies/minute Methodology assumptions from Energy Star calculator

52 52 Non-Weather Sensitive Measures Non-Residential Measures  Vending Machine Controls Characterized in two measures by being installed in: Cold drink vending machines Uncooled snack vending machines Measure savings and characterization from the Pacific Northwest Regional Technical Forum database Methodology assumes operated during off-peak hours, thereforeno demand savings

53 53 Non-Weather Sensitive Measures Non-Residential Measures  Water Heating Savings expressed as % of base use Base use varies by building type. Come from the 1994 DEER study Measures: High efficiency gas water heater (7.1% savings) Point of use water heater (10% savings) Water circulation pump time clock (6% savings)

54 54 Non-Weather Sensitive Measures Non-Residential Measures  High Efficiency Motors Meet premium efficiency standards established by the Consortium for Energy Efficiency (CEE) Base efficiency meets Energy Policy Act (EPACT) minimum Motor sizes range from 1 HP to 200 HP Motor hours of operation vary by industry sector Motor loading from US DOE Motor Master software Peak demand based on a coincidence factor of 0.75

55 55 Non-Weather Sensitive Measures Non-Residential Measures  High Efficiency Motors - Calculation Energy savings (kWh) = (Motor HP / EPACT motor efficiency) * kW/HP * hours of operation * motor loading – (motor HP / premium motor efficiency) * kW/HP * hours of operation * motor loading Peak (kW) = (motor HP * kW/HP * coincidence factor / EPACT motor efficiency) - (motor HP * kW/HP * coincidence factor / premium motor efficiency)

56 56 Non-Weather Sensitive Measures Non-Residential Measures  Agricultural Measures Low pressure irrigation sprinkler nozzle Sprinkler irrigation to micro irrigation conversion Infrared film for greenhouses Greenhouse heat curtain Variable frequency drive for dairy pumps Ventilation fans or box fans High volume, low speed fans

57 57 Non-Weather Sensitive Measures Non-Residential Measures  Agricultural Measures  Methodology taken from Express Agricultural Work Papers  Irrigation savings varied by crop type Citrus trees Deciduous trees Field/vegetable Grapes  And water source Well Non-well


Download ppt "1 Database for Energy Efficiency Resource User Demonstration Jennifer Barnes Pacific Energy Center October 11, 2005."

Similar presentations


Ads by Google