1 Tulane, Louisiana Cornerstone Design Project Group: C09004 Matt Piatkowski – Foundation Engineer Don Lucas – Structural Engineer Dan Scannell – Architectural Engineer Ian Donahue – Building Thermal Engineer Evan Brent – Fluid System Engineer

2 Structural Analysis Raw Materials —Wooden Truss vs. Steel Truss —Asphalt Shingles vs. Clay Tiling —Underlayment Truss Design —Accommodate ‘Great Room’ —Provide some storage space Manufacture Style —Prefabricated —Custom built

3 Structural Analysis http://www.northlandtrusssystems.com/images/room_in_attic_big.gif Prefabricated Room-in-Attic Ideal angle: 36 ° Usable Area: 972 ft 2 Maximum Height: 12 ft Load from shingles: ~6,000 lbs

4 Foundation Analysis General Information: – Full, walkout basement – Storage and living space – Stepped footing – Waterproofing – Backfilled to promote drainage

5 Foundation Analysis Material options: – Wood, Poured Concrete, Cinderblock, Metal, Brick, Stone Considerations: – Strength, durability, cost, appearance, installation time

6 Foundation Analysis The relative advantage of each material in each area needing consideration is analyzed. Materials are ranked from 1 to 6, with 6 being best. Results are tabulated for easier comparison.

7 Foundation Analysis StrengthDurabilityCostInstallation time Appearance Wood 1166 Subjective Poured concrete 6641 Subjective Cinderblock 6654 Subjective Metal 2415 Subjective Brick 4333 Subjective Stone 3222 Subjective

8 Foundation Analysis Final Material Choice: Cinderblock – Due to its excellent strength and durability, cinderblock framing will provide a good foundation for the house. – Relatively lower pricing and easier installation provide homeowner with savings in cost and time. – Cinderblocks will be reinforced to increase tensile strength.

9 Architectural Engineering House Construction: 2x6 construction or 2x4 construction for exterior walls 2x6 has more potential for insulation than 2x4 Ceiling height, 8ft or 10ft 10ft ceilings allow for better circulation of hot air during summer House Layout: Atrium: in center of house or offset if center than two wings to house typical colonial layout if offset than layout is unique 1 st floor: Rooms: living room, bathroom, kitchen, office, atrium Bathroom has to exit to hallway: building code 2 nd floor: Rooms: 2 bedrooms, master bedroom, bathroom

10

11

12

13 Fluid Systems Design Evan B. Brent Fluid Systems Engineer Source: piping3.dwg, courtesy Glen Brent, P.E.

14 Purpose of System To quietly, efficiently move heat from the solar thermal panels to the storage system. To provide adequate storage of heat for the general operating of the domestic hot water and space heating needs of the house.

15 Rough System Overview Water is pumped to the collectors on the roof and gains heat there. Hot water flows into a heat exchanger in a heat storage tank in the basement, and is then begins the cycle again. Heat is pulled from the heat storage tank via two other coils, one for DHW, one for space heating, and pumped/zoned as specified by homeowner.

16 Heat Storage Tank Provides long term storage for overnight/multi- day use of space heating and DHW Can be heated from multiple sources easily, without changing SH or DHW side of system. (Solar, Conventional, Geothermal, Wood Boiler, etc) Downside: Can take up a lot of space. Sources: Personal experience, interview with Glen Brent, P.E.

17 Design Method Idea: Solar Only system Requirements: Maintain normal use of DHW and SH even in coldest weather (33 F), using only the BTU's supplied by the solar thermal system. A 625 gallon storage tank (estimated) with a working temperature range of 120 F to 190F has 8.34*625*(190-120) BTUs of energy stored, which is 364875 BTU's, which is less than 4.5 hours of just space heating for the house, based on estimated Heat Load (86339 BTU/hr) Conclusion: Solar Only system not viable unless solar thermal system can put out significant BTU/hr even under design temp., and storage tank BTU capacity can be increased. 1993 ASHRAE Handbook Fundamentals Climatic data for New O. the winter design temp is 33 deg. F., median annual extreme low temp is 27. Basic heat load estimated from calculator found at http://www.heatload.com/unico/heatloadpreform.htm (10/19/09)http://www.heatload.com/unico/heatloadpreform.htm

18 Options, Given No Solar Only Integration of a simple conventional oil furnace or gas furnace, for heating the heat storage tank via a separate heat exchanger. (hands off system, works without any effort by homeowner) Integration of a wood/coal fired boiler (more effort, but inexpensive) Integration of a geothermal system (highly expensive, but green) Photo: http://www.daigleoil.com/images/Tarmsoloplus.gif

19 Component choices Pump: Taco 00 controlled circulator pump series, or similar. Also considering Taco Solar Pumping Station. Decision will be made based on cost analysis and final system layout/head value. Heat Storage Tank: Size and type to be determined by final Heat Load and Solar Thermal BTU/hr, given design method discussed. Pipe: Most likely 1” or 3/4” copper. Safe in an overheat situation, cost is not prohibitive, all major system components are built to mate with it, no plastic taste. Miscellaneous components such as Check Valves, Expansion tanks, Zone Valves, Air Purgers, Aqua Stats, etc will be determined as final house and solar design is nailed down. Sources: Personal experience, interview with Glen Brent, P.E. Photos: http://www.taco-hvac.com/en/products/Water%20Circulation%20Pumps%20%26amp%3B%20Circulators/products.html?current_category=18 10/21/09 http://www.taco-hvac.com/en/products/Water%20Circulation%20Pumps%20%26amp%3B%20Circulators/products.html?current_category=18

20 Building Thermal By: Ian Donahue

21 Home Backround The framing and insulation contribute to the buildings energy efficiency. Home is located in Tulane, LA and is a Zone 2 hot- humid climate. The location encounters hurricanes and storms, along with having pest issues. The highest average temperature: 90.6°F The lowest average temperature: 41.8°F Design temperature differential: 23°F

22 Design Considerations Since Tulane is located in an area that sees hurricanes and other tropical storms a strong house is probably needed. Cheap/efficient construction should be utilized. The ability resist moisture damage as well as pest problems is a plus in this region of the country.

23 Designs Wood Framing 16” oc construction Conventional Siding 2x6” Wood Studs Metal Framing 24” oc construction Poured Concrete Cold Formed Steel C- Channels

24 Recommended R-Values DOE Recommended R-Values for Wood SpaceR-Value Attic38 Ceiling30 Floor13 Wall Cavity15 DOE Recommended R-Values for Metal SpaceR-Value Attic49 Floor25 Wall Sheathing5 Wall Cavity15

25 Proposed Materials Metal Framing MaterialR-Value Outside Film Air0.25 1" Stucco0.2 6" Concrete3.54 Metal Framing2.5 1.5" Polyisocyanurate10.8 3/4" Air1 5/8" Gypboard0.58 Indoor Film Air0.68 Total F8.75 Total I17.05 Wood Framing MaterialR-Value Outside Film Air0.25 Siding0.8 5/8" Plywood0.77 3.5" Wood Framing4.38 Fiberglass Batt11 5/8" Gypboard0.58 Indoor Film Air0.68 Total F7.46 Total I14.08

26 More Design This is a preliminary design and the floor and ceiling are yet to be completed. This design will need to be checked and verified from a computer model.

27 References http://www.steelframing.org/PDF/IssuePapers/InteriorWalls.pdf http://www.steelframing.org/PDF/FinalDesignGuideSept82008.pdf http://www.coloradoenergy.org/procorner/stuff/r-values.htm http://www.huduser.org/Publications/pdf/sfmh_rpt.pdf http://www.steelframing.org/PDF/SFA_Framing_Guide_final%202.pdf http://www.oikos.com/esb/36/Corrfact.html http://www.efficientwindows.org/glazing_.cfm?id=8 http://apps1.eere.energy.gov/buildings/publications/pdfs/building_americ a/34560.pdf http://apps1.eere.energy.gov/buildings/publications/pdfs/building_americ a/34560.pdf http://www.ornl.gov/cgi- bin/cgiwrap?user=roofs&script=ZipTable/ins_fact.pl http://www.ornl.gov/cgi- bin/cgiwrap?user=roofs&script=ZipTable/ins_fact.pl

28 Solar Thermal

29 Viessmann Manufacturing Company Inc. Model100-F300-T(2m)300-T(3m) Absorber Area [ft 2 ]252233 Optical Efficiency [%]74.382.5 Width [in]41.7555.7586.75 Height [in]93.7578.5 Depth [in]2.754.75 Weight [lb]94.899150 Cost [$]821.953135.95X Cost per Area [$/ft 2 ]30.2498.18X

30 Apricus Solar Company, Ltd. ModelAP-10AP-22AP-30 Absorber Area [ft 2 ]8.618.925.8 Fluid Capacity [oz]9.818.628.2 Width [in]31.364.486.4 Height [in]77.9 Depth [in]6.1 Weight [lb]77157209

31 Optimal Collector Angle Apricus Viessmann 300

32 Viessmann 300-T(3m) N = 12, Φ = 38 o, U = 255 gal

33 Apricus AP-22 N = 16, Φ = 29 o, U = 255 gal

34 Viessmann 100-F C = $30.24/ft 2, U = 255 gal