J. Valls, CMS L2-L3 Meeting, Sept 20021 ROD Production at CERN ROD Flow During Production ROD Flow at CERN ROD Testing Areas Infrastructure Equipment Requirements Document http://cern.ch/valls
2
J. Valls, CMS L2-L3 Meeting, Sept 2002 2 Goals To fully assemble, test and characterize a total of ~ 700 RODs …by the end 2004
3
J. Valls, CMS L2-L3 Meeting, Sept 2002 3 ROD Assembly Sequence Mechanical ROD (ROD frames + pipes) Electrical ROD (+ IC bus + IC boards + AOH) Full ROD (+ Silicon)
4
J. Valls, CMS L2-L3 Meeting, Sept 2002 4 ROD Flow During Production ROD electrical integration ROD mechanical integration IC bus and IC boards integration Optoelectronics integration CCUM, connectors, and cable assembly Electrical tests with FE hybrids Electrical RODs packaged and sent to FNAL and UCSB FNAL/UCSB ROD final qualification Basic ROD operation Digital tests and readout errors Bad channel identification OH scans Total gain and offset scans Operational bias voltage X-Y -source scans Cosmic ray runs ROD silicon integration ROD qualification Helsinki Goal: Ready by March 2003 CERN
5
J. Valls, CMS L2-L3 Meeting, Sept 2002 5 ROD Flow at CERN CERN Spare Modules Storage Bin CERN Single Module Test Setup CERN -Source X-Y Scan Table CERN Single ROD Test Setup FNAL & USBC Modules and ROD CERN ROD Storage Bin CERN ROD Cosmic Rack ROD OK ROD Failure ROD OK Module OK
6
J. Valls, CMS L2-L3 Meeting, Sept 2002 6 -Source X-Y Scan Table Patch panel with connectors (HV, LV, controls, cooling) X-Y movement arms 3 RODS (any type) Rigid cover
7
J. Valls, CMS L2-L3 Meeting, Sept 2002 7 Delivery Schedule for Electrical RODs Testing Capability Rate (4 RODs/day) Wheel integration
8
J. Valls, CMS L2-L3 Meeting, Sept 2002 8 ROD Testing Areas Building 598 ROD System Tests (prototypes SS, DS) Equipment Procurement and Quality Test Definitions for Production Building 596 Electrical ROD Assembly and Tests Building 186 ROD Production and Qualification Tests Tracker Assembly and Integration
9
J. Valls, CMS L2-L3 Meeting, Sept 2002 9 Building 186
10
J. Valls, CMS L2-L3 Meeting, Sept 2002 10 Building 186 (TOB Area) PS x-y Table Rod Hospital Cosmic Rack Cooling unit Cold room PS PS racks Rod storage PS racks Module Air cond 0.8 m 17.8 m 7.1 m Total Testing Area: 126 m 2 Tracker Assembly Hall Tracker Assembly Area 300 ROD capacity Goal: Ready by early 2003 Siemens 1 kW @ +5 0 C/32 0 C 5 kW @ +25 0 C (~400 W for 12 RODs)
11
J. Valls, CMS L2-L3 Meeting, Sept 2002 11 Infrastructure for 186 Gas Contact CERN gas working group Grounding Contact TIS (?) TIS Permissions Conditioning Work Cleaning Furniture procurement Pipe work Etc. Goal: Ready by Dec 2002
12
J. Valls, CMS L2-L3 Meeting, Sept 2002 12 Equipment Needed for Production DAQ Hardware 4 PC computers DAQ cards 1 ARC single module setup High Voltage CAEN SY-127 Mainframe (10 boards A343, 2 kV, 200 A) CAEN SY-1527 Mainframe (6 boards A1511, 2 kV, 10 A-1 mA) Current Monitoring (CERN MSGC picoAmmeters) Controls (CAENET V288 VME) Low Voltage DELPHI switching LV PS (redesigned) 3 LV control PS (testbench) Cooling Units (and interlocks) Siemens Uniphase Cooling Unit (C 6 F 14 ), 1 kW @ +5 0 C / +32 0 C Refrigeration Unit at Build. 186 (C 6 F 14 ), 5 kW @ +25 0 C DAQ Software XDAQ (beam-test program) XROD (system test) Qualification and Acceptance Criteria Software Integration into DB
13
J. Valls, CMS L2-L3 Meeting, Sept 2002 13 DAQ Test Setups at CERN Single electrical ROD setup (Build. 596) Single ROD setup (Build. 186) X-Y table setup (3 RODS) (Build. 186) Max. APVs OEC Channels OEC Boards MUX Cards PMC-FED TSC/FEC Cards 48242311 / 1 Max. APVs OEC Channels OEC Boards MUX Cards PMC-FED TSC/FEC Cards 144726811 / 1 Max. APVs OEC Channels OEC Boards MUX Cards PMC-FED TSC/FEC Cards 48242311 / 1 120101433 / 3 Total: 121032 / 2 Available: (Build. 598)
14
J. Valls, CMS L2-L3 Meeting, Sept 2002 14 ROD Types L1, L2 Double Sided RODs (DS) 12 modules, 4 APV 24 fibers L3, L4 Single Sided RODs (SS4) 6 modules, 4 APV 12 fibers L5, L6 Single Sided RODs (SS6) 6 modules, 6 APV 18 fibers