Development of a pad interpolation algorithm using charge-sharing.

Slides:



Advertisements
Similar presentations
GEM Chambers at BNL The detector from CERN, can be configured with up to 4 GEMs The detector for pad readout and drift studies, 2 GEM maximum.
Advertisements

And standard deviation
Digital Filtering Performance in the ATLAS Level-1 Calorimeter Trigger David Hadley on behalf of the ATLAS Collaboration.
Photodetector Timing Resolution Burle Micro-Channel Plate Photo Multiplier Tubes (MCP-PMTs) H. Wells Wulsin SLAC Group B Winter 2005.
LI Gain Curves Peter Litchfield Calibration Workshop, 6 th September 2005  Beginning to understand the LI system  Beginning to understand the software.
Study of Photon Sensors using the Laser System 05/7/12 Niigata University, Japan Sayaka Iba, Editha P. Jacosalem, Hiroaki Ono, Noriko.
1 Scintillating Fibre Cosmic Ray Test Results Malcolm Ellis Imperial College London Monday 29 th March 2004.
Calculating the Beam Position at the Ecal for DESY Run (Independent of Tracking) Hakan Yilmaz.
Beam profile vs time Analyzed Vx vs Vy distributions vs time for –Run 72 (13:26:02 – 28:25) –Run 73 (13:36:10 – 13:37:30) –Run 74 (43:12 – 44:21) Binned.
ECAL Testbeam Meeting, Rome 28 March 2007 Toyoko Orimoto Adolf Bornheim, Chris Rogan, Yong Yang California Institute of Technology Lastest Results from.
Y. Karadzhov MICE Video Conference Thu April 9 Slide 1 Absolute Time Calibration Method General description of the TOF DAQ setup For the TOF Data Acquisition.
J. Estrada - Fermilab1 AFEII in the test cryostat at DAB J. Estrada, C. Garcia, B. Hoeneisen, P. Rubinov First VLPC spectrum with the TriP chip Z measurement.
The Transverse detector is made of an array of 256 scintillating fibers coupled to Avalanche PhotoDiodes (APD). The small size of the fibers (5X5mm) results.
Tests with JT0623 & JT0947 at Indiana University Nagoya PMT database test results for JT0623 at 3220V: This tube has somewhat higher than usual gain. 5×10.
HCAL1 Status 2003 Oleg Gavrishchuk, JINR, Dubna 1. HCAL1 performance 2003 General design High Voltage system LED monitoring 2. Tests in muon halo beam.
Cube Measurements Tent Crew. Scintillation BNL 241 Am Semi- collimated  Spectralon Diffuse UV Reflector SBD  -Trigger Scint. Light Poisson.
 Candidate events are selected by reconstructing a D, called a tag, in several hadronic modes  Then we reconstruct the semileptonic decay in the system.
14/02/2007 Paolo Walter Cattaneo 1 1.Trigger analysis 2.Muon rate 3.Q distribution 4.Baseline 5.Pulse shape 6.Z measurement 7.Att measurement OUTLINE.
Experimental set-up Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE Multi-Channel MCP PMTs S.Korpar a,b, R.Dolenec.
Outrigger Timing Calibration & Reconstruction Milagro – 11/17/03 Shoup – 1 Purpose: To incorporate outrigger hits in event angle fitting Additionally incorporated.
Analysis of Endstation A setup Josef Uher. Quartz bar Start counter.
A.Chekhtman1 GLAST LAT ProjectBeam test meeting, September 27, 2006 CsI afterglow - possible explaination of pedestal drift and excess of energy. Alexandre.
“End station A setup” data analysis Josef Uher. Outline Introduction to setup and analysis Quartz bar start counter MA and MCP PMT in the prototype.
Experimental set-up for on the bench tests Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE/Photonis Multi-Channel.
1 xCAL monitoring Yu. Guz, IHEP, Protvino I.Machikhiliyan, ITEP, Moscow.
11 Sep 2009Paul Dauncey1 TPAC test beam analysis tasks Paul Dauncey.
Objectives Determine Detector offsets in hall B reference frame and thus absolute beam position at Hycal Examine Flux calculation and see if beam trips.
1 Development of Multi-Pixel Photon Counters (1) S.Gomi, T.Nakaya, M.Yokoyama, M.Taguchi, (Kyoto University) T.Nakadaira, K.Yoshimura, (KEK) Oct
Simonetta Gentile, LCWS10, March 2010, Beijing,China. G-APD Photon detection efficiency Simonetta Gentile 1 F.Meddi 1 E.Kuznetsova 2 [1]Università.
1 A.Andronic 1, H.Appelshäuser 1, V.Babkin 2, P.Braun-Munzinger 1, S.Chernenko 2, D.Emschernmann 3, C.Garabatos 1, V.Golovatyuk 2, J.Hehner 1, M.Hoppe.
Charge Sharing & Hit Identification & Cluster Information.
MPPC status M.Taguchi(kyoto) T2K ND /7/7.
PMT gain check at Indiana University. Test setup inside dark box LED white paper PMT # JT0298 channel #2 (per HPK numbering) OTHER CHANNELS MASKED WITH.
Hycal Energy Resolution, Timing, &Trigger Efficiency, A cumulative study. Chris Mauney.
Status of photon sensor study at Niigata University -- SiPM and MPPC -- Photon sensor mini workshop 05/9/16 University Niigata University.
Feature Extraction IceCube Collaboration meeting in Berkeley, March 2005 Dmitry Chirkin, LBNL.
Test beam preliminary results D. Di Filippo, P. Massarotti, T. Spadaro.
1 P.Rebecchi (CERN) “Monitoring of radiation damage of PbWO 4 crystals under strong Cs 137  irradiation in GIF-ECAL” “Advanced Technology and Particle.
Feature Extractor Dima Chirkin, LBNL The future is here.
PIXEL SCANS. Measuring Data Measure last point before graphs cuts off at 1/10³. Measure last point before graphs cuts off at 1/10³. For spread of data,
1 Oct 2009Paul Dauncey1 Status of 2D efficiency study Paul Dauncey.
04/06/07I.Larin pi0 systematic error 1  0 error budget Completed items (review) Updated and new items (not reported yet) Items to be completed.
1 M2-M5 Efficiency and Timing checks on 7TeV beam data Alessia, Roberta R.Santacesaria, April 23 rd, Muon Operation
Jet + Isolated Photon Triple Differential Cross Section Nikolay Skachkov: “Photon2007”, Paris, 9-13 July 2007 DO Measurement of Triple Differential Photon.
CALICE, CERN June 29, 2004J. Zálešák, APDs for tileHCAL1 APDs for tileHCAL MiniCal studies with APDs in e-test beam J. Zálešák, Prague with different preamplifiers.
Testbeam analysis Lesya Shchutska. 2 beam telescope ECAL trigger  Prototype: short bars (3×7.35×114 mm 3 ), W absorber, 21 layer, 18 X 0  Readout: Signal.
HCAL1 Status 2004 Oleg Gavrishchuk, JINR, Dubna 1. HCAL1 performance in 2004 General design High Voltage system LED monitoring 2. Stability in 2003 Led.
E. Picatoste, D. Gascon PMT afterpulsing and SPD trigger 1 Looking to the problem from the instrumentation point of view LHCb Calorimeter Meeting – CERN.
M. Martemianov, ITEP, October 2003 Analysis of ratio BR(K     0 )/BR(K    ) M. Martemianov V. Kulikov Motivation Selection and cuts Trigger efficiency.
M.Taguchi and T.Nobuhara(Kyoto) HPK MPPC(Multi Pixel Photon Counter) status T2K280m meeting.
28/11/02Guy Dewhirst1 Ultra Light Weights Method Guy Dewhirst Imperial College London.
11 june 2002 CMS ECAL : Patrick Jarry ( Saclay) 1 Pulse shape reconstruction : CMS ECAL Introduction –the problem –the tools –experimental pulse shape.
Performance of 1600-pixel MPPC for the GLD Calorimeter Readout Jan. 30(Tue.) Korea-Japan Joint Shinshu Univ. Takashi Maeda ( Univ. of Tsukuba)
Development of Multi-Pixel Photon Counters (1)
Preliminary Analysis of the New Focusing DIRC Prototype Beam Data
LED notched fibre distributing system Calibration system for SiPM
Fabio, Francesco, Francesco and Nicola INFN and University Bari
Laser Geiger cell (update)
Transversal calibration of Geiger Cells
EZDC spectra reconstruction and calibration
techniques and studies
PCB 3043L - General Ecology Data Analysis.
Pulse Shape Fitting Beam Test September, October CERN
Slice Test: Preliminary Data Analysis The Ohio State University
Update on TB 2007 Xtal Irradiation Studies at H4
The time-of-flight reconstruction & calibration
Calorimeter calibrations with Flight Software.
Status report Minjung Kim
Programs for the calibration of TOF measurement with the new pulser
Performance test of a RICH with time-of-flight information
Presentation transcript:

Development of a pad interpolation algorithm using charge-sharing

Charge sharing between two pads When a photon hits the MCP between two pads, the avalanches shares the charge to two pads. We want to find a method to determine the photon position for this type of events using both TDC and ADC information from the two pads. e- photon photocathode MCP/dynodes anode pads TDC/ADC

PMT scan configuration For PMT scan, the photon are sent by an optic fiber positioned with a precision of few microns. So, we know where the photons hits the pad with an high precision. In addition, for each trigger we measure TDC and ADC values. If a TDC value is within a certain window ( counts), we call it an event (a photon hit). optic fiber photon PMT

Position of laser for single TDC hit (no ADC information used) I have plotted the position of the laser for events with a single TDC hit. On the border of each pad, there are fewer single events (probably multiple events). Region outside of 4-pad region (blue color) is due (a) photon scatters in the lens optics, or (b) avalanche charge sharing

Position of laser for double TDC hit (no ADC information used) If two TDC fire at the same time on two pads, I plot one event at the position of the laser beam. These types of events happen near the border between two pads. In the center of 4 pads, there is less of double events (there is probably triple and quadruple events)

Position of laser for triple TDC hit (no ADC information used) Triple TDC events happen near the center of the four pad. Triple events represent only 10.1% of all multiple events

Position of laser for quadruple TDC hit (no ADC information used) Quadruple TDC events happen near the center of the four pad. Quadruple events represents only 2.5% of all multiple events

Statistics on TDC events multiplicity (no ADC information used) MultiplicityNumber of events Proportion % % % % Single events Double Events Triple events Quadruple events There is a considerable fraction of double events due to the charge sharing. Therefore, it would be useful to use them to improve the photon hit position. Concerning triple and quadruple hit, there are few. It’s probably sufficient to consider that photon have hit middle of the 4 pads.

ADC pedestal fit I have used the scan 20, where a laser light is blocked, although the laser is on. It measures a pedestal distribution. I fit the pedestal distribution for each pad with a ROOT macro and store the results in a file. The negative values of pedestal are stored on the 2 first bins. 5  cut33

Pedestal peak Photon Peak Gain measurement I fit the ADC distribution of scan 27 with a sum of two gaussian function. The first gaussian has only one free parameter (amplitude), the other parameter are parameters found for pedestal run. All the second gaussian parameters are free, but their start values are choose in order to catch the ADC peak. Gain = photon peak position – pedestal peak position

Position of laser for single ADC hit (no TDC information used) I have plotted the position of the laser for events with a single ADC hit above the cut. On the border of each pad, there are fewer single events (probably multiple events). Region outside of 4-pad region (blue color) is due (a) photon scatters in the lens optics, or (b) avalanche charge sharing ADC Cut = 

Position of laser for double ADC hit (no TDC information used) If two ADC above the cut fire at the same time on two pads, I plot one event at the position of the laser beam. These types of events happen near the border between two pads. In the center of 4 pads, there is less double events (there is probably triple and quadruple events) ADC Cut = 3 

Position of laser for triple ADC hit (no TDC information used) If three ADC above the cut fire at the same time on three pads, I plot one event at the position of the laser beam ADC Cut = 3 

Position of laser for quadruple ADC hit (no TDC information used) ADC Cut = 3  If four ADC above the cut fire at the same time on four pads, I plot one event at the position of the laser beam.

Statistics on ADC events multiplicity (no TDC information used) MultiplicityNumber of events Proportion % % % % Single events Double Events Triple events Quadruple events The proportion of multiple hit is more important for ADC. So, if there is a TDC hit only, it would be useful to use the ADC in order to find with a better precision, where is the photon.

Study of corrected function ADC21/(ADC22+ADC21) = f(x) Each ADC value is corrected with a formula: ADC cor = (ADC-Pedestal Peak Position)/Gain Events are cut if the ADC of the two pads are under 5  ADC cut. x y Zone used to fill the hisogram mm Pad 22 Pad 21

Fit of corrected function ADC21/(ADC22+ADC21) = f(x) I have extract the profile function of the previous graph on a 2mm range around the border in order to have only the ratio of ADC as a function of x or y (depends of the border choose). For different pads, p1 varies between 0.51 and ps varies between 0.35 and I have generated a file containing the results of fits of all borders (Fit_Profile.txt). Events are cut if the ADC of the two pads are under 5  ADC cut. Fitted with y = p2.erf(p1.(x-p0))

Test of interpolation x y Zone used to fill the histogram mm 4 mm An event is interpolated if there is a TDC hit on pad 21 or 22 and ADC 21 and ADC 22 pass a 3  ADC cut. There is a cut on the ADC Ratio (0.1<Ratio<0.9). Ratio = ADC21cor/(ADC21cor+ADC22cor) x predicted = erf -1 ((Ratio-0.5)/0.5684)/0.342

Estimation of error on x The cut are the same as in the previous slide. The error is more little than 1mm. Consequently, the precision is significantly better than the size of a pad. The error distribution is not a gaussian. There is a large tail due to (a) photon scatters in the lens optics, or (b) avalanche charge sharing, or (c) a S/N ratio.

Effet of S/N on the tail When cut on pulse height (ADC) increases, a number of events decreases and a tail of the distribution becomes shorter. A compromise have to be done on pulse height (ADC) cut. 0  2  8  6  4  0  2  8  6  4  A large tail corresponds to poor S/N ratio, which corresponds to small pulse heights.

Conclusion 90% of multiple hit are double hit. Double hit are essentially localized near the border of 2 pads. In order to improve the measurement of photon position, it’s possible to use ADC information if the photon hit near a border. The error made with this method is typically 0.9 mm.