Fire Resistance Rated Truss Assemblies Educational Overview.

Slides:



Advertisements
Similar presentations
Wood Structural Panels
Advertisements

Carpentry Skilled Trades Ceiling and Roof Framing The most commonly used types of residential roof and ceiling construction are: Joist and Rafter.
HEAD-OF-WALLS. Presenter-Brice Miller 23 years as Building Official, Inspector and Plans Examiner 23 years as Building Official, Inspector and Plans Examiner.
FCIA CODE EFFORTS FCIA Spring Conference 2003 By William E. Koffel, P.E. Koffel Associates, Inc.
Building Construction A fire resistive rating (FRR) is given in minutes or hours and relates to how long it takes to burn through a given material. Expressions.
Heavy Timber Materials and Methods. What is Heavy Timber Type 4 Construction Heavy timber also referred to as Mill construction or slow burning construction.
PERMITS & INSPECTIONS DEPARTMENT 2003 INTERNATIONAL RESIDENTIAL CODE IRC.
Fire Requirements For Foam Plastic Insulation and WRBs in Exterior Walls Presented to By Jesse J. Beitel July 31, 2012.
CTC 422 Design of Steel Structures
Chapter 23 Interior Walls & Partitions. Interior Partitions Performance Criteria  Strength  Fire Resistance  Durability  Acoustical Isolation Materials.
Fire.
Lumber Section II. Lumber Structural Strength Depends on species and grade, and the direction in which the load is acting with respect to grain of the.
Wall and Ceiling Construction Vocabulary
FPF190: Fire Protection Fundamentals FPF190 Fire Protection Fundamentals 1 Code Consultant.
Fire and Emergency Services Company Officer — Lesson 17 Fire and Emergency Services Company Officer, 4 th Edition Chapter 17 — Preincident Planning.
Energy Performance and Moisture Control of Ceilings and Roofs 1.
Governmental Constraints on Construction Chapter 2.
© 2006 ITT Educational Services Inc. CD230 Architectural Design & Drafting: Unit 10 Slide 1 Unit 10 Commercial Construction.
Attachment of Residential Deck Ledger to Metal Plate Connected Wood Truss Floor Systems Overview.
International Fire Door Inspector Association Presents New Annual Fire Door Inspections NFPA 80 – 2007, 2010, 2013 Standard for Fire Doors and Other Opening.
Fire-Related Properties of Materials Chapter 7. Mehta, Scarborough, and Armpriest : Building Construction: Principles, Materials, and Systems © 2008 Pearson.
Electrical Safety in Construction. Objectives In this course, we will discuss the following: Common electrical hazards Standards relating to those hazards.
2010 Florida Building Code: I nterpretation P rocess O verview.
Building Classifications: Construction Types.  Based on how the building is constructed.  Relates to:  Materials used  Combustibility  Fire-resistance.
Code Officials and the Code Process.  To design the interior of the building in conjunction with codes, standards and federal regulations required in.
Construction Type of Buildings
Engineering Analysis of NFPA 285 Tested Assemblies
Firestopping – Filling the Gaps Makes a Difference Poole Fire Protection Brian Griffin & Jack Poole, PE 2007 DOE Contractor Fire Protection Workshop Argonne.
Picking up from last week…. Fire stair layout Fire stair layout Due October 18 th Due October 18 th Assignment #1.
Chapter 28 Structural Components of Framed Construction.
Chapter 5 ID 234 Building Codes Fire Resistant Materials and Assemblies.
Construction Types Chapter 3.
Fire-Resistant Materials & Assemblies Part 2 Chapter 5.
Building Industry Authority Determination 2003/3 Commentary Paul Clements.
Code Officials and the Code Process.  Concentrates on the code process as a whole.  Different type of code officials  Various steps that are taken.
Sprinkler Loads on Trusses
MWFRS Method v/s Components and Cladding Method for Truss Uplift Connection Design for Wind Overview.
Truss Repair and Modifications Educational Presentation.
Position Statement on Sealed Truss Placement Diagrams for the State of California (including Los Angeles) Overview.
Plumbing Radiant Heating & Cooling Turf Conditioning Permafrost Ice and Snow Melt Ecoflex ® SupportSustainabilityEngineered PolymerCommercial SystemsIntroductions.
Sprinkler Loads on Trusses Educational Presentation.
Steep Slope Roofing Systems. Based on the 2007 C.B.C. Presented by Oscar Davalos.
Overdriven Nails in Structural Sheathings Overview.
Inspection and Quality Assurance Requirements for Metal Plate Connected Wood Trusses Educational Overview.
Building Construction
Lay-On Gable Frame Connection Overview. Introduction A lay-on gable frame is typically connected from the top during truss placement, but after sheathing.
Meet the DBI Pros Summit October 25, 2006 Amy Lee, Acting Director HIGH RISES AND THE CHANGING SAN FRANCISCO SKYLINE.
Fire Retardants and Truss Design Overview. Introduction Fire retardant treatments (FRT) were developed to be applied to building materials, such as dimension.
2-Hour Fire Endurance Assembly for MPCWT Structural Floor and Roof Framing Systems Educational Overview Revised 8/12/2016.
FRT Lumber Use in Type III-A Buildings
Truss Heel Heights and Energy Code Requirements
Bottom Chord Live Load Concurrency and Truss Design
Use of Resilient Channel or Hat Channel to Meet the Lateral Restraint/Bracing Requirements of the Bottom Chords of MPCWT Floor Systems Overview Revised.
Position Statement on Sealed Truss Placement Diagrams for the State of Texas Overview Revised 3/23/2017.
Use of Cantilevered Sill Plates with MPCWT to Align with Varying Thicknesses of Exterior Sheathing Overview Revised 3/22/2017.
Impact of C&C loads due to ASCE/SEI 7-16
Construction Documents
Educational Overview Revised 10/2/2017
Structural Fire Engineering, October 2015, Dubrovnik, Croatia
NFPA 600, INDUSTRIAL FIRE BRIGADE Module : 11 BUILDING CONSTRUCTION.
Educational Overview Revised 6/13/2017
Wood Structures Topic 8 Quality Workmanship
Building Construction
Overdriven Nails in Structural Sheathings
Land Use and Development Regulations
Water-Resistive Barriers: Assuring Consistent Assembly Water Penetration Resistance Educational Overview Revised August 31, 2018.
Position Statement on Sealed Truss Placement Diagrams for the 2012 or 2015 International Residential Code Overview Revised 3/23/2017.
Common Components of a Traditional Wood Framed Building
Floor Truss Ribbon Board Load Path
BCAR & The Technical Guidance Documents Conference 2019 Part E: Sound
Presentation transcript:

Fire Resistance Rated Truss Assemblies Educational Overview

Introduction Building codes may require a fire endurance rating for several applications where trusses are used: – Floor/ceiling – Roof/ceiling – Attic separation

Generic fire rated wood truss assembly

Introduction Truss protection in fire resistance rated assemblies is covered in the IBC States that requirements shall be based on “the results of full-scale tests or combinations of tests” or “approved calculations based on such tests” that demonstrate fire resistance Truss protection.

Key Definitions Approved Source: An independent person, firm or corporation, approved by the building official, who is competent and experienced in the application of engineering principles to materials, methods or systems analyses. Fire Resistance: That property of materials or their assemblies that prevents or retards the passage of excessive heat, hot gases or flames under conditions of use. Fire-Resistance Rating: The period of time a building element, component or assembly maintains the ability to confine a fire, continues to perform a given structural function, or both, as determined by the tests, or the methods based on tests, prescribed in Section 703. Section 703

Introduction The IBC allows five methods for determining fire resistance (Section 703.3):Section Fire-resistance designs documented in sources. 2.Prescriptive designs of fire-resistance-rated building elements, components or assemblies as prescribed in Section 721.Section Calculations in accordance with Section 722.Section Engineering analysis based on a comparison of building element, component or assemblies designs having fire ‑ resistance ratings as determined by the test procedures set forth in ASTM E119 or UL Alternative protection methods as allowed by Section Section

Method 1: Documented fire-resistance designs To qualify as a documented design, testing is performed in accordance with one of the following tests: – ASTM E119 Standard Methods for Fire Tests of Building Construction and Materials ASTM E119 – ANSI/UL 263 Fire Resistance Ratings ANSI/UL 263

Method 1: Documented fire-resistance designs Tested assemblies may be specified where a rated assembly is required Assemblies can generally be applied to both floor and roof applications

Method 1: Documented fire-resistance designs Some sources of documented fire-resistance designs include: Gypsum Association – Fire Resistance Design Manual (GA-600) – Online Manual (read only) Online Manual (read only)

Method 1: Documented fire-resistance designs Underwriters Laboratories: – Fire Resistance Directory – Searchable Database Searchable Database Many UL tested designs can also be found in the product literature of companies whose products are certified to be listed in the assemblies

Method 1: Documented fire-resistance designs Other sources of documented fire-resistance designs include: – Warnock Hersey (Intertek Directory)Intertek Directory – Factory Mutual Factory Mutual – PFS Corporation PFS Corporation

Method 1: Documented fire-resistance designs General: – The fire resistance rating of listed assemblies applies to the entire assembly – Components are NOT intended to be interchanged between assemblies.

Method 1: Documented fire-resistance designs However, evaluation by comparison of tested assemblies is permitted by IBC Section Method 4.Section 703.3

Method 1: Documented fire-resistance designs Depth/Spacing: – Depths given are minimums Greater depths are allowed – Spacings given are maximums Smaller spacings are allowed Maximum spacing Minimum depth

Method 1: Documented fire-resistance designs Insulation: – Some assemblies allow addition of insulation if an additional layer of gypsum is installed at the ceiling.

Method 1: Documented fire-resistance designs However, IBC Section Method 4 and Method 5 permit modifications to assembliesSection This would include modifications involving insulation – Rational design must be provided to the building official

Method 1: Documented fire-resistance designs Use of floor/ceiling designs for roof/ceiling (or reverse): – UL BXUV.GuideInfo Section III.19 states: UL BXUV.GuideInfo Class A, B or C roof coverings may be used on floors without reducing the fire-resistance rating A nailer of equal thickness to the length of the mechanical fasteners must be added to the flooring

Method 1: Documented fire-resistance designs Use of floor/ceiling designs for roof/ceiling (or reverse): – The reverse case is not typical – Floor/ceiling designs that specify a finish floor cannot be used as roof/ceiling assemblies

Method 1: Documented fire-resistance designs However, IBC item 4 or item 5 would allow use of assemblies tested as floor/ceiling or roof/ceiling in the other application, even if not specified as such in the listing – Rational design must be provided to the building official.

Method 2: Prescriptive designs IBC Table 721.1(3), item describes one prescriptive 1-hour rated floor or roof assembly that includes wood trusses:Table 721.1(3) Max spacing 24” 1/2" (min) WSP glued & attached w/8d nails at right angles to truss/joist Base layer: 5/8" Type X gyp attached w/1-1/4” Type S or W drywall 24” o.c. at right angles to truss/joist Face layer: 5/8" Type X gyp or veneer base attached thru base layer w/1- 7/8” Type S or W drywall screws 12” o.c. at joints and intermediate truss/joist. Type G drywall screws placed 2” back on either side of face layer end 12” o.c.

Method 2: Prescriptive designs The National Building Code of Canada (NBC) 2010 provides an extensive listing of prescriptive assemblies that include metal plate connected wood trusses in Table A B. These listings also include sound ratings, so can be very useful to the building designer.

Method 3: Calculated designs IBC Section addresses fire resistance calculations for wood assembliesSection – The unexposed side membrane is NOT included in the calculation Fire-exposed side membrane + Framing members + Other (e.g. Insulation) = Fire-resistance rating (minutes)

Method 3: Calculated designs The maximum fire- resistance rating allowed using this method is 1-hour. This section includes tables with times assigned to both structural members and membranes.

Method 4: Comparison The IBC allows the determination of fire resistance ratings based on a comparison of building element, component or assembly designs having fire-resistance ratings as determined by the test procedures set forth in ASTM E119 or UL 263.

Method 4: Comparison Combined with the provisions of IBC Section listed at item 5, this allows the building official to approve a design that "complies with the intent of the provisions of this code, and that the material, method or work offered is, for the purpose intended, at least the equivalent of that prescribed in this code in quality, strength, effectiveness, fire resistance, durability and safety."

Method 4: Comparison SBCA has calculated a two hour fire rated MPCWT assembly based on this provision See SBCA SRR for full details

Method 4: Comparison One basis for this type of analysis is Harmathy’s “Ten Rules of Fire Endurance Rating” Consult Section 4-13 in the SFPE Handbook of Fire Protection Engineering for further infoSection 4-13

Method 5: Alternative materials and methods Alternative materials, design and methods of construction and equipment. – The provisions of this code are not intended to prevent the installation of any material or to prohibit any design or method of construction not specifically prescribed by this code, provided that any such alternative has been approved. An alternative material, design or method of construction shall be approved where the building official finds that the proposed design is satisfactory and complies with the intent of the provisions of this code, and that the material, method or work offered is, for the purpose intended, at least the equivalent of that prescribed in this code in quality, strength, effectiveness, fire resistance, durability and safety.

Method 5: Alternative materials and methods This allows for other methods of developing a design by an approved source that complies with the intent of the code and, unless it can be demonstrated not to comply with the code, should be approved by the building official.

Conclusion A Building Designer may submit to a code jurisdiction a fire resistance rated design incorporating metal plate connected wood trusses using any of the five methods allowed by Section Section If it is not a listed design, the Building Designer should submit details regarding how the submitted design was determined and show how it complies with the intent of the building code.

References SBCA Research Report National Design Specification ® for Wood Construction (NDS ® ) 2012 or 2015, American Wood Council (AWC), Section 16, Fire Design of Wood Members. National Design Specification Analytical methods for determining fire resistance of timber members, Robert White, 2008, included in the SFPE handbook of fire protection engineering. Quincy, Mass.; National Fire Protection Association; Bethesda, Md.: Society of Fire Protection Engineers, c2008: pages Analytical methods for determining fire resistance of timber members Guidelines on Fire Ratings of Archaic Materials and Assemblies. International Code Council (ICC). Guidelines on Fire Ratings of Archaic Materials and Assemblies National Building Code of Canada, National Building Code of Canada

References International Building Code (IBC), 2012 and 2015, International Code Council (ICC). International Building Code BXUV.GuideInfo, Underwriters Laboratory. BXUV.GuideInfo Gypsum Association Handbook, GA-600, 2012 Gypsum Association Handbook Fire Resistance Provided by Gypsum Board Membrane Protection, GA-610, 2013 Fire Resistance Provided by Gypsum Board Membrane Protection ESR-1338, Gypsum Wall and Ceiling Assemblies and Gypsum Board Interior and Exterior Applications ESR-1338 Intertek Directory of Certified Products PFS Corporation Factory Mutual