The fault occurred at the level of 400V-500V. Investigation of the fault to ground at the RCS.A34B2 circuit Between 3 and 12 September, 2014 we carried.

Slides:



Advertisements
Similar presentations
Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
Advertisements

RAD Engineering BLM VME J2 Backplane Printed Circuit Board Backplane Crosstalk Comparison January 25, 2005.
LIMITS AND DERIVATIVES 2. The idea of a limit underlies the various branches of calculus.  It is therefore appropriate to begin our study of calculus.
3. COMPOSITE VIDEO SIGNAL Prepared by Sam Kollannore U. Lecturer, Department of Electronics M.E.S.College, Marampally, Aluva-7.
ADT490 TroubleShooting Locating Grounds A. 2 Introduction ‣ Fire Alarm Panels cannot tolerate grounds ‣ A ground on any fire alarm circuit is detected.
Digital Logic Design Lecture # 17 University of Tehran.
During fault behavior of circuit breaker
Transmission Lines Demonstration High Frequency Electronics Course EE527 Andrew Rusek Oakland University Winter 2007 Demonstration is based on the materials.
Physics 1304: Lecture 13, Pg 1 Faraday’s Law and Lenz’s Law ~ B(t) i.
Electric Circuits AP Physics 1.
Statistical Techniques I EXST7005 Lets go Power and Types of Errors.
PRINCIPLES OF MEASUREMENT AND INSTRUMENTATION EKT 112
Veto Wall Test Hyupwoo Lee MINERvA/Jupiter Group Meeting Feb, 13, 2008.
Veto Wall Test Hyupwoo Lee MINERvA/Jupiter Group Meeting Oct, 3, 2007.
Veto Wall Test Hyupwoo Lee MINERvA/Jupiter Group Meeting July 18, 2007.
David Nelson STAVE Test Electronics July 21, ATLAS STAVE Test Results Version 1 David Nelson July 21, 2008.
1 Lab Equipment. 2 TopicSlides DC Power Supply3-4 Digital Multimeter5-8 Function Generator9-12 Scope – basic controls13-20 Scope – cursors21-24 Scope.
Network Theorems SUPERPOSITION THEOREM THÉVENIN’S THEOREM
Large Cell Scope Pictures, Part II HV Gnd 1nF Large Cell Tube Anode signal Phi Cathode signal scope S1 S2 S1 S2 This is a follow-up on Richard’s measurement.
4 Series Circuits Chapter Topics Covered in Chapter 4
ITOP carrier amplifier test at Indiana University G. Visser 4/27/2015 (latest update) I use the recently (here) characterized JT0947 ch3 as input source.
ELECTRICITY & MAGNETISM
Test of the high voltage strength of Pelletron’s gas insulation (18-Dec-2008) Recycler Meeting January 21, 2009 A. Shemyakin.
CHAPTER 9 Oscilloscopes and Graphing Multimeters
Large Cell Scope Pictures HV Gnd 1nF Large Cell Tube Anode signal Cathode signal scope S1 S2 S1 S2 The following scope pictures were all taken with the.
Waveform 2.1 Basic Digital Waveforms 2 Measurement Paul Godin Updated October 2009.
09/16/2010© 2010 NTUST Today Course overview and information.
Time Response of Reactive Circuits
ENE 103 Electrotechnology
rectangular waveguides x z y 0 a b 0 TE or H mode.
13.2: Current and Voltage Objectives: Ampere Voltage Volt Voltmeter
Chapter 17 – Methods of Analysis and Selected Topics (AC) Introductory Circuit Analysis Robert L. Boylestad.
Fundamentals of Electromagnetics and Electromechanics
6-2: STANDARD NORMAL AND UNIFORM DISTRIBUTIONS. IMPORTANT CHANGE Last chapter, we dealt with discrete probability distributions. This chapter we will.
Oscilloscope Muhajir Ab. Rahim School of Mechatronic Engineering
Fundamental of Electrical Engineering
Differential Equations 7. Direction Fields and Euler's Method 7.2.
Corrosion control measurements Incorrect assumptions are making pipeline corrosion control impossible.
Thursday, Nov. 3, 2011PHYS , Fall 2011 Dr. Jaehoon Yu 1 PHYS 1444 – Section 003 Lecture #18 Thursday, Nov. 3, 2011 Dr. Jaehoon Yu Torque on a Current.
Electric Current and Resistance Physics. Potential Difference  Charges can “lose” potential energy by moving from a location at high potential (voltage)
AP Physics C Electric Circuits.
DIFFERENTIAL EQUATIONS 10. DIFFERENTIAL EQUATIONS Unfortunately, it’s impossible to solve most differential equations in the sense of obtaining an explicit.
Velleman Oscilloscope: Windows 7 by Mr. David Fritz.
Experiment 10: Inverting Amplifier With Modifications that Require the Use of the Velleman Oscilloscope.
Level 2 Electromagnetism Laboratory Experiment
T RANSIENTS AND S TEP R ESPONSES ELCT222- Lecture Notes University of S. Carolina Fall2011.
Circuits and Circuit ElementsSection 1 © Houghton Mifflin Harcourt Publishing Company Today’s special SAT QOTD HW check: vocab 20 Notes HW I due next!
Vectors and the Geometry of Space Section 10.4 Lines and Planes in Space 2015.
Unit 3, Chapter 7 Integrated Science. Unit Three: Electricity and Magnetism 7.1 Voltage 7.2 Current 7.3 Resistance Chapter 7 Measuring Electricity.
Electric Circuits AP Physics C. Potential Difference =Voltage=EMF In a battery, a series of chemical reactions occur in which electrons are transferred.
Protection of Power Systems
Chapter 9 CAPACITOR.
LOCATION OF CABLE FAULTS
PREPARED BY: PREPARED BY: PRATIK PATEL DEEP SANGANI G H PATEL COLLEGE OF ENGINEERING AND TECHNOLOGY.
DONE BY : RAWDA ALNWAISEH BAYAN TALEB
Chapter 21 Magnetic Induction and Chapter 22.9: Transformers.
Unit 11 - Electric Circuits Physics Book Chapters 19 and 20 Conceptual Physics Book Chapters 33, 34, 35.
S3 Physics – Exam revision
Electrical insulation of magnet circuits in sector 7-8
Induced Voltages and Inductance
Consequences of warming-up a sector above 80 K
THREE-PHASE GROUND-FAULT BASICS
Chapter 5 Transistor Bias Circuits
Electric Circuits.
Inductance Chapter 29 opener. One of the great laws of physics is Faraday’s law of induction, which says that a changing magnetic flux produces an induced.
Copyright © Cengage Learning. All rights reserved.
Differential Equations
6. USING THE TDR200 IN ANALOGUE MODE
Presentation transcript:

The fault occurred at the level of 400V-500V. Investigation of the fault to ground at the RCS.A34B2 circuit Between 3 and 12 September, 2014 we carried out the investigation of the short to ground which demonstrated itself as a voltage break in the RCS.A34B2 magnet circuits People involved : G. D’Angelo, P. Jurkiewicz, M.Martinez, Z. Natkaniec, W. Ostrowicz, D. Wojas

Measurement setup (Fig. 1) Investigation of the fault to ground at the RCS.A34B2 circuit

HV source - connected to spool no. 10 and to ground. Two 25m coax cables connected to two oscilloscope channels get signal from Vtaps D20_C1. Each end of the coax cables terminated with a special type of AC 50 ohm TERMINATOR CH1 connected to the right side of the fragment and used as a trigger CH2 connected between Vtaps D20_C1 and ground CH3 = CH1-CH2. Investigation of the fault to ground at the RCS.A34B2 circuit

It is based on measuring the time delay of the signal passing through the selected sections of the magnets. According to Figure 1, if the HV breakdown occurs on the right side of the sections, the falling edge of the signal first triggers CH1, and then after a time DELAY it appears in CH2. It results in a negative pulse in channel CH3. Investigation of the fault to ground at the RCS.A34B2 circuit Principles of measurements

If the HV breakdown occurs to the left of the sections, it will result in the falling edge of the signal which will first appear in CH2, and the subtractions in CH3 will give a positive pulse. Investigation of the fault to ground at the RCS.A34B2 circuit Principles of measurements In this way, by performing measurements at various positions along the tunnel, we have been able to find the location of the damage.

If the HV breakdown occurs to the left of the sections, it will result in the falling edge of the signal which will first appear in CH2, and the subtractions in CH3 will give a positive pulse. Investigation of the fault to ground at the RCS.A34B2 circuit Principles of measurements In this way, by performing measurements at various positions along the tunnel, we have been able to find the location of the damage.

Investigation of the fault to ground at the RCS.A34B2 circuit Results of the measurement in first investigation on spool no. 10 (between 3 and 5 September) Conditions of measurements: P He =1 bar in all half-cells, except 15L4/14L4 where P air =1bar

Test1: A16-CH2(blue) B15-CH1(yellow). M1(brown) = CH1-CH2. Breakdown to Conclusion: HV-break is on the left side of the measured section (the differential pulse is positive – pulse in CH2-blue is first - ). HV-break is not too close to the measured position. We could estimate the distance between the HV-break and the measured point on the basis of the sharpness of the edges of the pulses.

Test 2: C34-CH2(blue) A34-CH1(yellow). M1(brown) = CH1-CH2. Real breakdown to Conclusion: HV-break on the right side of the measured section (differential pulse is negative – pulse in CH1-yellow is first). HV-break is far from the measured position (the slope is mild). The delay between the pulses is about 228ns.

Test 3: B23-CH2(blue) C22-CH1(yellow).. M1(brown) = CH1-CH2. Breakdown to Conclusion: HV-break on the right side very close to the measured position (delay is still about 228ns).

Test 4: A22-CH2(blue) B21-CH1(yellow). M1(brown) = CH1-CH2. Real breakdown to 500V. Conclusion: HV-break on the left side very close to the measured position.

Test 5: C22-CH2(blue) A22-CH1(yellow). M1(brown) = CH1-CH2. Real breakdown to 500V. Conclusion: HV-break is between the probes (between CH1 and CH2) exactly on the position (delay is shortened dT~150ns)

Investigation of the fault to ground at the RCS.A34B2 circuit Final conclusion: HV-break occurs in half-cell 22L4 between magnets A22L4 and B22L4. The exact location of the damage can be estimated from the structural drawings of the corresponding magnets. For safety reasons it is recommended to apply a bypass to both magnets B22L4 and A22L4

Results of the measurement in second investigation on spool no. 9&10 Results of the measurement in second investigation on spool no. 9&10 after opening A22L4-B22L4 Previous Conditions of measurements: P He =1 bar in all half-cells, except 15L4/14L4 where P air =1bar Current Conditions of measurements: P He =1 bar in all half-cells, except 15L4/14L4 and 22L4 where P air =1bar

Test 1: C22-CH2(blue) A22-CH1(yellow).. Conclusion: When we monitored spools #10, we observed HV-break on spool # 9 far from 22L4. The pulse does not approach zero ​​ in a specified time. After opening interconnection in the position 22L4 HV-break disappeared, and it appeared on the spool no. 9 Measurement at the -22L4 position of the detected HV-break. Initially, only spool #10 was cut here. The CH1 connected directly to spool #10

Test 1a: A19-CH2(blue) B18-CH1(yellow). M1(brown) = CH1-CH2 Real breakdown to 450V. Conclusion: HV-break on the right side very close to the measured position. Signal in CH1 (yellow) is first, subtraction pulse is negative. We examined the magnet chain, performing measurements in different locations using the method discussed above. The test results given below are confined to the last tests on the location close to the located failure. CH 2CH 1 QC19B19A19Q18C18B18AQ17C17B17A MCS _9

Test 2a: B18-CH2 (blue) C17-CH1 (yellow). M1(brown) = CH1-CH2 Real breakdown to 450V. Conclusion: HV-break on the left side very close to the measured position. Signal in CH2 (blue) is first, subtraction pulse is positive. CH 2CH 1 QC19B19A19Q18C18B18AQ17C17B17A MCS _9

Test 3a: A19-CH2(blue) C17-CH1(yellow). M1(brown) = CH1-CH2 Real breakdown to 450V. Conclusion: HV-break point is inside the measured section of the magnets, close to the centre of the measured section. Pulses CH1 and CH2 practically overlap. A) Real Pulse (from real break) CH 2CH 1 QC19B19A19Q18C18B18AQ17C17B17A MCS _9

Conclusion: HV-break occurs in the half-cell 18L4, most likely in the magnet B18L4. An accurate short position can be calculated based on the actual mechanical dipole drawing. B) Artificial Pulse (from artificial break - HV=200V). Artificial short on B18L4. In order to determine the exact place of the break, we made an artificial short on the position B18L4. The resulting signal on the oscilloscope is almost identical to the real short-circuit. Test 3a: A19-CH2(blue) C17-CH1(yellow). M1(brown) = CH1-CH2 Real breakdown to 450V.

After opening the interconnection, the short on position 22 L4 disappeared permanently and it was highly probable that the situation would happen again in position 18L4. Accordingly, we tried to overtake this problem and force the same conditions as those existing in the cell 22L4 (that is with the pressure equal to 1 bar of air), but before opening the interconnection. After opening the cryogenic valves in half-cell 18L4 and providing (air -1 bar) the proper conditions, we performed an HV test. This time the HV test passed, which means that the short disappeared. After restoring conditions of 1 bar helium the short circuit occurred again in half-cell 18L4 at about HV = 400V. Activity after establishing a HV short spool 9:

Conclusions: Similar phenomena occurred in both cells 22L4 and 18L4. A short circuit appears at cryogenic conditions (helium = 1 bar) and disappears in the air conditions. Recommendations: In the 18L4 we suggest repeating tests at conditions: helium 6 bar. Perform bypass on both half-cells 18L4 and 22L4. Activity after establishing a HV short spool 9: