Luminosity Monitor Design MICE Collaboration Meeting 31 May 2009 Paul Soler.

Slides:



Advertisements
Similar presentations
NDVCS measurement with BoNuS RTPC M. Osipenko December 2, 2009, CLAS12 Central Detector Collaboration meeting.
Advertisements

Stefan Roesler SC-RP/CERN on behalf of the CERN-SLAC RP Collaboration
COSMIC RAY MUON DETECTION USING SCINTILLATION COUNTER AND WAVELENGTH SHIFTING FIBERS ARUNODAYA BHATTACHARYA VSRP-2009,TIFR,MUMBAI 6/7/09.
MICE TARGET OPERATION C. Booth, P. Hodgson, R. Nicholson, P. J. Smith, Dept. of Physics & Astronomy University of Sheffield, England.
Robert Cooper
Robert Cooper L. Garrison, L. Rebenitsch, R. Tayloe, R. Thornton.
MICE Beam-line and Detectors Status Report 16 th October 2009 Chris Booth The University of Sheffield.
MICE Particle Rate and ISIS Beam Loss Adam Dobbs, Target – ISIS Meeting, 17 th September 2010.
Particle ID in the MICE Beamline MICE Collaboration Meeting 30 March Paul Soler, Kenny Walaron University of Glasgow and Rutherford Appleton Laboratory.
MICO Alain Blondel 17 March MICO Alain Blondel 17 March MICE target test-run March 2008 Friday 14/03/2008 6:00-> 18:00 Saturday 15/03/2008.
Linda R. Coney – 24th April 2009 MOM Update Linda R. Coney 21 September, 2009.
Linda R. Coney – 24th September 2009 MOM Update End of Sept Run Linda R. Coney 05 October, 2009.
Mar 31, 2005Steve Kahn -- Ckov and Tof Detector Simulation 1 Ckov1, Ckov2, Tof2 MICE Pid Tele-Meeting Steve Kahn 31 March 2005.
Luminosity Monitor Commissioning MICE Collaboration Meeting March 2010 Paul Soler, David Forrest Danielle MacLennan.
MICE: The International Muon Ionization Cooling Experiment Diagnostic Systems Tracker Cherenkov Detector Time of Flight Counters Calorimeter Terry Hart.
Linda R. Coney – 24th April 2009 MOM Update Linda R. Coney 14 September, 2009.
Y. Karadzhov MICE Video Conference Thu April 9 Slide 1 Absolute Time Calibration Method General description of the TOF DAQ setup For the TOF Data Acquisition.
MARS flux simulations - update Sergei Striganov Fermilab August 12, 2009.
Luminosity Monitors MICE Video Conference 7 May 2009 Paul Soler.
MOM Report Paul Soler MICE Operations Manager University of Glasgow MICO April 26, 2010.
MUON FLUX MEASUREMENTS AT THE LSC JRA1-N2 Meeting, Zaragoza, Nov 23 rd 2007 Héctor Gómez Maluenda, University of Zaragoza.
MICO 8 th February 2010 Terry Hart (MOM) - Decay Solenoid and Target - MICE Machine Physics runs - Problems and Issues.
Neutron background measurement at LNGS: present status Measurement carried out in collaboration between LNGS ILIAS-JRA1 and ICARUS groups.
MOM - M.ApollonioAccel. R&D/Physics and IADR - RAL - 19/3/ Summary of MICE operations – 14/15 March 2008 AIMS - establish MICE beamline in ISIS synchrotron.
Jun 27, 2005S. Kahn -- Ckov1 Simulation 1 Ckov1 Simulation and Performance Steve Kahn June 27, 2005 MICE Collaboration PID Meeting.
CMPB Alain Blondel 14 April STATUS OF MICE.
Forward Detectors and Measurement of Proton-Antiproton Collision Rates by Zachary Einzig, Mentor Michele Gallinaro INTRODUCTION THE DETECTORS EXPERIMENTAL.
1 M. Bonesini - CM 25 RAL 5/11/09 PID status report M. Bonesini Sezione INFN Milano Bicocca.
Update on the Gas Ring Imaging Cherenkov (GRINCH) Detector for A 1 n using BigBite Todd Averett Department of Physics The College of William and Mary Williamsburg,
MICE CM26 March '10Jean-Sebastien GraulichSlide 1 Detector DAQ Issues o Achievements Since CM25 o DAQ System Upgrade o Luminosity Monitors o Sequels of.
The PEPPo e - & e + polarization measurements E. Fanchini On behalf of the PEPPo collaboration POSIPOL 2012 Zeuthen 4-6 September E. Fanchini -Posipol.
A scintillation detector for neutrons below 1 MeV with gamma-ray rejection Scintillators are 3 mm BC408, 10 layers total Adjacent layers are optically.
Background measurements and simulation Hayg Guler Marc Verderi LLR – Ecole polytechnique ATF2 project meeting, June 2009.
Feb 10, 2005 S. Kahn -- Pid Detectors in G4MicePage 1 Pid Detector Implementation in G4Mice Steve Kahn Brookhaven National Lab 10 Feb 2005.
FLC Group Test-beam Studies of the Laser-Wire Detector 13 September 2006 Maximilian Micheler Supervisor: Freddy Poirier.
DE/dx measurement with Phobos Si-pad detectors - very first impressions (H.P Oct )
Energy Distribution of Cosmic Ray Muons Paul Hinrichs With David Lee Advised by Phil Dudero.
Possibility for Double DVCS measurement in Hall A Alexandre Camsonne SBS Meeting June 4 th 2013.
MICE Beam-line and Detectors Status Report 16 th October 2009 Chris Booth The University of Sheffield.
Status of Beam loss Monitoring on CTF3 Results of Tests on LINAC and PETS as R&D for TBL Anne Dabrowski Northwestern University Thibaut Lefevre CERN CTF3.
Digital analysis of scintillator pulses generated by high-energy neutrons. Jan Novák, Mitja Majerle, Pavel Bém, Z. Matěj 1, František Cvachovec 2, 1 Faculty.
Luminosity Monitor UKNF Meeting 7 June 2010 Paul Soler, David Forrest Danielle MacLennan.
Linda R. Coney – 24th September 2009 MOM Update Linda R. Coney 24 September, 2009.
C.Vigorito, University & INFN Torino, Italy 30 th International Cosmic Ray Conference Merida, Mexico Search for neutrino bursts from Gravitational stellar.
RAL Muon Beam Line Properties. ISIS 70 MeV H- injection Ring accelerates up to 800 MeV in about 10 ms 50 Hz cycle - Dual Harmonic System ~ 2 x 1.5 MHz;
Tracker Timing and ISIS RF Edward Overton 1. At CM32… 2 Had done some preliminary checks on the ISIS RF. Was beginning to think about how to handle the.
MICE TARGET OPERATION C. Booth, P. Hodgson, P. J. Smith, Dept. of Physics & Astronomy University of Sheffield, England. 1 – The MICE Experiment2 - The.
1 Measurement of particle production from the MICE target Kenny Walaron, Paul Soler University of Glasgow.
March 18, 2008 TJRMICE Beamline Status1 MICE Beamline Status (March 18, 2008) Tom Roberts Muons, Inc. Illinois Institute of Technology.
DVCS – Hall A Study of the Background Noise HUGS 2008 Florian ITARD.
Target tests 1 st – 2 nd Nov. Chris Booth Sheffield 7 th December 2006.
Instrumentation and Simulations for Target Test MICE Collaboration Meeting 22 October Bill Murray 1, Paul Soler 1,2, Kenny Walaron 1,2 1 Rutherford.
IEEE NSS 2007 D.Kramer 1 Very High Radiation Detector for the LHC BLM System based on Secondary Electron Emission Daniel Kramer, Eva Barbara.
Progress in the construction of the MICE cooling channel and first measurements Adam Dobbs, EPS-HEP, 23 rd July 2011.
Medium baseline neutrino oscillation searches Andrew Bazarko, Princeton University Les Houches, 20 June 2001 LSND: MeVdecay at rest MeVdecay in flight.
- MICE - The Muon Ionization Cooling Experiment Jean-Sebastien Graulich, Univ. Genève o Introduction: Aims And Concept o Design o Infrastructure: Hall,
MICE CM39 St Catherine’s, Oxford, 26 June 2014 Paul Soler Instrumentation Global Commissioning Plan.
T2K Status Report. The Accelerator Complex a Beamline Performance 3 First T2K run completed January to June x protons accumulated.
Low Momentum dE/dx Testbeam H.P. 7/24/98. Goals for Spectrometer are based on tracking and PID –Multiparticle correlation –production of particle species.
Thomas Roser Snowmass 2001 June 30 - July 21, 2001 Proton Polarimetry Proton polarimeter reactions RHIC polarimeters.
All Experimenters MeetingDmitri Denisov Week of July 22 to July 29 D0 Summary  Delivered luminosity and operating efficiency u Delivered: 3.1pb -1 u Live:
1 Work report ( ) Haoqi Lu IHEP Neutrino group
Eli Piasetzky Tel Aviv University Beam Scintillating Fibers PSI, Technical Review, July 2012 Guy Ron Hebrew University Israel.
PSD Front-End-Electronics A.Ivashkin, V.Marin (INR, Moscow)
Luminosity Monitor Status
K. Sedlak, A. Stoykov, R. Scheuermann
Conceptual design of TOF and beam test results
K. Tilley, ISIS, Rutherford Appleton Laboratory, UK Introduction
Particle ID Diagnostics in the MICE Beamline
Segmented high resolution fast neutron spectrometer:
Presentation transcript:

Luminosity Monitor Design MICE Collaboration Meeting 31 May 2009 Paul Soler

2 P Soler, MICE CM24, 31 May 2009 Purpose of Luminosity Monitors o Alain gave good rationale for having luminosity monitors during MICE run at Video Conference 9 April o Use luminosity data to determine protons on target as function of depth – independent of beam loss monitors o Beam loss monitors have not been very stable as function target depth – can be used to detect early problems target

3 P Soler, MICE CM24, 31 May 2009 Purpose of Luminosity Monitors (cont.) o Cross-correlate luminosity monitor (close to target), which measures mainly protons and pions, with other counters downstream (more sensitive to pions or muons) o Validation of beamline simulations o Comparison with beam-loss monitors to determine protons- on-target (pot) BLM calibrations as function of KE:

4 P Soler, MICE CM24, 31 May 2009 MARS Distributions at Scintillator Plane MARS Distributions at Scintillator Plane Unshielded 5 cm polyethylene shielding  Simulations: 10 Million protons on MICE target, KE = 800 MeV (from 2006) MARS yields in simulated area of 40x40 cm 2 at 10 m distance Number particles P (MeV/c)

5 P Soler, MICE CM24, 31 May 2009 GEANT4 Distributions at Scintillator Plane Unshielded 5 cm polyethylene shielding GEANT4 yields in simulated area of 40x40 cm 2 at 10 m distance Number particles  Simulations: 10 Million protons on MICE target, KE = 800 MeV (from 2006) P (MeV/c)

6 P Soler, MICE CM24, 31 May 2009 Design consideration Luminosity Monitors o Best way to monitor luminosity is by counting protons from target o 15 cm plastic (5.5 cm Al) stops: — 500 MeV/c protons (R/M~16) — 150 MeV pions (R/M~110). o 5 cm plastic (1.9 cm Al) stops: — 350 MeV/c protons (R/M~5.3) — 100 MeV/c pions (R/M~36) o To also stop neutrons, maybe add a thin layer of cadmium.

7 P Soler, MICE CM24, 31 May 2009 Particle Counters in 2006  Two sets of detectors at 10 m distance, 30 o angle ̶ 1 pair of shielded scintillators: 3x3x30 mm 3 (with 5 cm polyethylene shielding) ̶ 1 unshielded pair of detectors: 10x10x10 mm 3 ̶ Scope DAQ and readout to Linux PC via GPIB  Signals from scintillators and ISIS read out recorded using oscilloscopes for each 10 ms burst Unshielded detectors Position of detectors (same angle as MICE beam)  Discrimination and coincidence of each scintillator pair performed offline Example of coincidence

8 P Soler, MICE CM24, 31 May 2009 Data taking Nov 2006  Number of particles recorded by detectors during last 2 ms of spill (KE= MeV) when target expects to dip in beam  Correlation between beam loss and number of particles in last 2 ms of spill recorded by detectors  50 mV integrated beam loss signal corresponds to 2.8x10 9 protons on target (calibration: 3.5x V s/proton at 9 ms with ~50% error) Shielded detectors Unshielded detectors

9 P Soler, MICE CM24, 31 May 2009 o For example, let’s take beam loss of 50 mV: o From MARS simulation at 780 MeV: o So, the expected number of singles in 1 cm 2 is: o So, most particles observed in target test were protons o Not surprising, since we had very little shielding o If we want to discriminate integrated proton flux above energy threshold then introduce shielding between first pair and second pair scintillators Back of envelope calculations (in last two milliseconds) (compare to observed rate in slide 8)

10 P Soler, MICE CM24, 31 May 2009 Particle Yields (Nov 2006)  From MARS and GEANT4 simulation, calculate number of singles in 100 mm 2 area of unshielded and 90 mm 2 of shielded detectors from simulations of 10 7 pot in 1600 cm 2, with simulated efficiencies  From data, use slope of particles/beam loss plot and convert into particles/pot, using calibration.  We found good agreement between data, MARS and GEANT4, compatible within systematic errors of calibration (~50%). Singles/pot (Unshielded) (x10 -8 ) Singles/pot (Shielded) (x10 -8 ) Ratio * Shielded/ Unshielded MARS (stat) (stat) GEANT (stat) (stat) DATA (stat) (syst) (stat) (syst) * Systematic error due to the calibration of the beam loss monitors cancels in the ratio All described in MICE-NOTE-227

11 P Soler, MICE CM24, 31 May 2009 o Possible design of box for luminosity monitors: o Rate: for beam loss monitors running 50 times higher level (ie. beam loss ~2.5 V) would mean around 2000 particles/cm 2 in final 2 ms of spill (ie ~1 MHz proton rate) Proposed design of Luminosity Monitors Cuts off protons ~300 MeV/c Cuts off protons ~500 MeV/c ~2cm 2 Thin layer Cd

12 P Soler, MICE CM24, 31 May 2009 o Use Hamamatsu H5783P PMTs: — Small, fast, high gain tubes — 0.8 ns rise time — ~1x10 6 gain — Packaged, so only need up to 15 V Photomultipliers o Cost: £632 per unit (we already have two units so should cost around £1300) o Readout: use NIM coincidence units and count using scalers (already implemented in DAQ, use spare channels) o Final issues: lay cables from MICE hall to ISIS vault and low voltage power supply o Aim to install on Q1 August 09 shutdown 50 mm

13 P Soler, MICE CM24, 31 May 2009 o Luminosity monitors will really help in the commissioning of the beamline — Will allow us to understand the protons on target as function of target depth with high accuracy — System designed to monitor secondary protons from target (>300 MeV/c and >500 MeV/c) o It is a rather inexpensive addition to beamline o If given approval can be delivered/installed in August Conclusions