Proposed Changes to PTCS Duct Standards April 7 th, 2009 Regional Technical Forum.

Slides:



Advertisements
Similar presentations
Energy Efficiency in Rehab Late 1980s – RIP Early 1990s – energy standards developed Approx 20 pages Prescriptive Lowering energy usage Controlling moisture.
Advertisements

How to lower the energy use of your home David Parker Building Analyst/ Energy Auditor Parker Energy Solutions David Parker Building Analyst/ Energy Auditor.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – July 2012eere.energy.gov Building Science Basics WEATHERIZATION INSTALLER/TECHNICAN FUNDAMENTALS.
Chapter 8: Duct Design and Sealing To be used with the Guide to Building Energy Efficient Homes in Kentucky.
ENERGY STAR Qualified Homes
GEOTHERMAL AND SOLAR PANEL INSTALLATION BY GRACE BALDWIN.
Key HVAC Design Concepts. Agenda Discuss relevance of thermal enclosure system to HVAC system. Present the three major steps to design an HVAC system.
Environmental Health Issue- Carbon Monoxide Presented by QBE Loss Control Services.
PTCS Aeroseal Specification Approval Measure Proposal Presentation to the Regional Technical Forum June 28, 2011.
Student Book © 2004 Propane Education & Research CouncilPage Performing Pressure Tests on Gas Distribution Lines Gas personnel must understand.
Deeming Savings for Ductless Heat Pumps in Manufactured Homes Regional Technical Forum January 4 th, 2011.
Residential Weatherization and Ventilation Subcommittee Progress Recap and Initial Recommendations January 4, 2011 Subcommittee: Residential Weatherization.
Standardized Curriculum WAP Training Plans and Resources.
NEEM Manufactured Homes Field Test Results David Baylon, Ecotope.
HVACR416 - Design Pressure Measurement Part 2. Pressure Measurement Several pressure measurements exist. They all measure the same things, the force of.
PTCS DUCT SEALING SPECIFICATIONS The Perfect Spec : Simple as possible Achievable by the motivated, not just the true believer Assure that energy savings.
Training the Best Workforce! Larry D. Armanda Therma-View Infrared and Energy Consultants S. Williamsport, PA & A. Tamasin Sterner Pure Energy Coach LLC.
Prescriptive Duct Sealing UES Measure Proposal Regional Technical Forum Subcommittee July 8, 2013.
2009 Fall MMSC Home Energy Makeover House #1 Chris Baryo Residence 4165 N 850 E Churubusco, Indiana.
VENTING AND COMBUSTION AIR
Your House as a Healthy System Bruce Stahlberg. Improvements / Remodeling When one has finished building one's house, one suddenly realizes that in the.
Residential New Construction Montana House: UES Measure Update Adam Hadley Regional Technical Forum April 14, 2015.
Residential Weatherization and Ventilation Specs Subcommittee Updates Regional Technical Forum March 2 nd, 2010.
Residential Weatherization and Ventilation Subcommittee Seeking RTF Direction on Ventilation and IAQ Requirements May 3, 2011 Subcommittee: Residential.
Installation. Indoor Unit Installation Typical Installation.
Of moderated conference calls on energy efficiency Utility Brown Bag Series PTCS Commissioning Updated following May 17, 2006 Conference Call Speakers:
Residential Weatherization and Ventilation Subcommittee: Infiltration Impact Research Plan Presentation to the Regional Technical Forum February 14, 2012.
ASHRAE A Ventilation Standard for Residential Structures Ventilation and Acceptable Indoor Air Quality in Low- Rise Residential Buildings.
Residential Single Family HVAC UES Measures Proven and Planning UES Measure Proposals Adam Hadley Regional Technical Forum December 16, 2014.
PTCS Aeroseal Specification Approval Measure Proposal Presentation to the Regional Technical Forum June 28, 2011.
Residential Weatherization and Ventilation Subcommittee Presentation to the Regional Technical Forum August 30, 2011.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – July 2012eere.energy.gov Combustion Safety WEATHERIZATION INSTALLER/TECHNICAN FUNDAMENTALS.
Residential Ventilation & IAQ Requirements for Existing Homes History, ASHRAE 62.2, and the RTF’s Role Regional Technical Forum October 13 th, 2009.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Manufactured Homes Weatherization UES Measures Regional Technical Forum June.
Oregon ENERGY STAR Homes Measure Update Adam Hadley Regional Technical Forum March 17, 2015.
Air Source Heat Pump Specifications Proposed Revisions Regional Technical Forum Subcommittee July 2, 2013.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Single Family Weatherization and HVAC UES Measures Follow-up from August RTF.
Residential Duct Insulation New Deemed Measure Proposal – A Second Look Regional Technical Forum May 4 th, 2010.
HVACR416 - Design Pressure Measurement Part 1. Why Measure? Need to Make Sure: All combustion appliances vent properly All HVAC systems are installed.
Residential Weatherization and Ventilation Subcommittee: Infiltration Impact Research Plan Presentation to the Regional Technical Forum December 13, 2011.
Northwest Power Planning Council Residential Space Conditioning and Domestic Hot Water Conservation Resource Assessment Overview of Analytical Process.
PTCS Commissioning, Controls & Sizing Update of UES Measure Category and/or Status Regional Technical Forum July 15, 2014.
Proposed Changes to PTCS Duct Sealing Specifications & Standards RTF January 23 rd 2033 Bob Davis & Bruce Manclark.
1 Proposed Changes to the RTF’s Heat Pump Deemed Savings and Cost- Effectiveness Draft 6th Plan Assumptions April 7, 2009.
PSE Delta Q Project Results Bruce Manclark, Delta T Bob Davis, Ecotope RTF meeting, 5 January 2009.
PTCS Ducts Inside Single Family New Construction Energy Savings and Cost Regional Technical Forum May 5,
Incremental Cost Assessments & Duct Sealing Optimization Project Bobbi Wilhelm March 25, 2008.
Applying SEEM Updates, Calibration, and Measure Interaction Decisions to: Manufactured Homes Weatherization UES Measures Regional Technical Forum December.
Residential Weatherization and Ventilation Specs Subcommittee Updates Regional Technical Forum March 2 nd, 2010.
RTF Management Updates Jennifer Light Regional Technical Forum December 8, 2015.
PTCS Subcommittee Recommendations ARHI Certification for Standalone Heat Pump Commissioning and Controls Measures AND Simplified Heat Pump Sizing Method.
Planning UES Measures: SF New Construction Heat Pump Upgrades (9.0 HSPF and VCHP) Heat Pump Commissioning Controls and Sizing Adam Hadley Regional Technical.
Retrofit PTCS Duct Sealing SGC Manufactured Homes Energy Savings Analysis.
Planning UES Measures: Prescriptive Duct Sealing SF Performance-based Duct Sealing SF Performance-based Duct Sealing MH Adam Hadley & Josh Rushton Regional.
Proposed Edits to the Air Source Heat Pump Specifications Regional Technical Forum August 20, 2013.
1 Proposed Energy Star New Homes Deemed Savings – Interior Ducts & HVAC April 10, 2007.
Proposed Changes to PTCS Service Provider Standards And other PTCS Issues March 2 nd, 2009 Regional Technical Forum.
3.0 Comprehensive Performance Audit Fossil Fuel Appliances Health & Safety 3.2.
Day 1 Part 4 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
Day 2 Part 2 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov Duct Sealing and Insulation TRAIN THE TRAINER WEATHERIZATION.
Day 4 Part 2 Technician’s Guide & Workbook for Home Evaluation and Performance Improvement.
Management of PTCS Service Providers Subcommittee Recommendation Regional Technical Forum July 7 th, 2009.
Technician’s Guide & Workbook for Duct Diagnostics and Repair.
SCG-SH-0200 Southern Company Generation Clearance Procedure Awareness Training for Contractors and Nonlisted Personnel.
Part 4 Technician’s Guide & Workbook for Duct Diagnostics and Repair
Part 12 Technician’s Guide & Workbook for Duct Diagnostics and Repair
Part 2 Technician’s Guide & Workbook for Duct Diagnostics and Repair
Things you need to know before you play the game
North Carolina Department of Insurance Office of State Fire Marshal
Presentation transcript:

Proposed Changes to PTCS Duct Standards April 7 th, 2009 Regional Technical Forum

Subcommittee Conference Call February 24, 2009 Attendees: – Mark Johnson – David Hales – Andres Morrison – Bruce Manclark – Mark Jerome – Brady Peeks – Adam Hadley Outcome: Developed recommended changes to the PTCS Duct Standards

PTCS Duct Standards Subcommittee-Recommended Changes 1.Put all “duct testing procedures” language in a separate document. 2.Remove “program standards” language, which required a specific pre-existing leakage rate for manufactured homes (the dry hole test). (Old p.7 #2) – Note: This is not a recommendation to programs to stop pre-screening for payment, simply a recommendation to take the language out of the duct standards document. 3.Significantly reformat/organize document to make it “spec-like”.

PTCS Duct Standards Subcommittee-Recommended Changes 4.Add a requirement to replace insulation. (New 5.2) New Language: Where a large section of duct insulation is removed, the insulation shall be re-installed and securely attached to the duct system. Recommended methods include the use of twine. Mastic will not effectively hold insulation in place.

PTCS Duct Standards Subcommittee-Recommended Changes 5.Add the following External Static Pressure “should” to New Homes and Existing Homes/New Ducts section: (New and 6.2.5) New Language: “If a new air handler is being installed, the total external static pressure acting on the system air handler should be tested with approved instruments and recorded at time of startup. A measured external static pressure of more than 0.8” (200 Pa) should cause installer to consider taking corrective measures with system ductwork.“ Note: This is not a “shall” in the duct specs because it is a “shall” for PTCS heat pumps. In the case of a gas furnace, a “shall” here would hand this responsibility to the duct sealing contractor - something the subcommittee didn’t want to do. Furthermore, the existing contractors are not trained to do this test.

PTCS Duct Standards Subcommittee-Recommended Changes 6.Update the supply side only test leakage requirements (Old p.5 section C; New 6.3.4) Old Language: In extreme cases where return ducts are inaccessible, compliance with either (0.10CFM50 x ft2) or (50% reduction) may be accomplished by testing the supply side only New Language: In cases where return ducts are inaccessible, compliance with (0.10CFM50 x ft2) or (50% reduction) may be accomplished by performing the Duct Leakage to the Exterior test on the supply side only (using the more stringent of the two – whichever is less). Reason for the Change: The subcommittee agreed this is what has been intended all along, and that the previous specification was in error.

PTCS Duct Standards Subcommittee-Recommended Changes 7.Modify Manufactured Home language: (Old p.7 #5; New 6.4.4) Old language: If the final tested leakage rate is greater than 75 CFM 50, the air handler-to-duct transition connection shall be sealed with proper materials. New language requires: If the final tested leakage rate is greater than 50 CFM 50 for single wide homes, plus an additional 30 CFM 50 for each additional section, the air-handler transition-to-trunk duct connection shall be sealed.

PTCS Duct Standards Subcommittee-Recommended Changes 8.Remove all CAZ testing requirements; modify CO alarm requirement. (Old p.3 #3&4, p.4 #3&4, p.5 #2&3, p.7 #3&4; New 7.1) Old Language: Based on the protocol for “Combustion Appliance Zone Pressure Testing” forced air system operation shall not de-pressurize a combustion appliance zone by more than 3 Pascals. When combustion appliances are located within a conditioned space a UL listed carbon monoxide alarm, or equivalent must be installed. New Language: Whenever there is a Combustion Appliance present in the house, garage, or other attached space, a UL listed, C-UL listed, or equivalent carbon monoxide alarm shall be installed in accordance with the carbon monoxide alarm manufacturer’s instructions. Reason for the Change: The CAZ test is not always a reliable test. Test repeatability is questionable. It is also not possible to perform the test in all weather conditions.