R Frey LCWS071 A Silicon-Tungsten ECal with Integrated Electronics for the ILC -- status Currently optimized for the SiD concept Baseline configuration:

Slides:



Advertisements
Similar presentations
LC Calorimeter Testbeam Requirements Sufficient data for Energy Flow algorithm development Provide data for calorimeter tracking algorithms  Help setting.
Advertisements

J-C. BRIENT (LLR) 1  Introduction with pictures  Prototype design and construction  R&D on the design of the full scale calorimeter CALICE - ECAL silicon-tungsten.
Bulk Micromegas Our Micromegas detectors are fabricated using the Bulk technology The fabrication consists in the lamination of a steel woven mesh and.
Adding electronic noise and pedestals to the CALICE simulation LCWS 19 – 23 rd April Catherine Fry (working with D Bowerman) Imperial College London.
Victoria04 R. Frey1 Silicon/Tungsten ECal Status and Progress Ray Frey University of Oregon Victoria ALCPG Workshop July 29, 2004 Overview Current R&D.
7 January 2005 MDI Workshop M. Breidenbach 1 SiD Electronic Concepts SLAC –D. Freytag –G. Haller –J. Deng –mb Oregon –J. Brau –R. Frey –D. Strom BNL –V.
10 Nov 2004Paul Dauncey1 MAPS for an ILC Si-W ECAL Paul Dauncey Imperial College London.
R Frey 9/15/20031 Si/W ECal Update Outline Progress on silicon and tungsten Progress on readout electronics EGS4 v Geant4 Ray Frey M. Breidenbach, D. Freytag,
7 June 2006 SLAC DOE Review M. Breidenbach 1 KPiX & EMCal SLAC –D. Freytag –G. Haller –R. Herbst –T. Nelson –mb Oregon –J. Brau –R. Frey –D. Strom BNL.
The SiD concept Yannis Karyotakis LAPP Annecy / IN2P3 March 21 st ‘05.
Design Considerations for a Si/W EM Cal. at a Linear Collider M. Breidenbach, D. Freytag, G. Haller, M. Huffer, J.J Russell Stanford Linear Accelerator.
R Frey ESTB20111 Silicon-Tungsten Electromagnetic Calorimeter R&D Collaboration M. Breidenbach, D. Freytag, N. Graf, R. Herbst, G. Haller, J. Jaros, T.
NIU Workshop R. Frey1 Reconstruction Issues for Silicon/Tungsten ECal R. Frey U. Oregon NIU Workshop, Nov 8, 2002.
28 June 2002Santa Cruz LC Retreat M. Breidenbach1 SD – Silicon Detector EM Calorimetry.
ICLC Paris R. Frey1 Silicon/Tungsten ECal for SiD – Status and Progress Ray Frey University of Oregon ICLC Paris, April 22, 2004 Overview (brief) Current.
27 th May 2004Daniel Bowerman1 Dan Bowerman Imperial College 27 th May 2004 Status of the Calice Electromagnetic Calorimeter.
LCWS2002 R. Frey1 Silicon/Tungsten ECal for the SD Detector M. Breidenbach, D. Freytag, G. Haller, M. Huffer, J.J Russell Stanford Linear Accelerator Center.
ITBW07 R. Frey1 ECal with Integrated Electronics Ray Frey, U of Oregon Ongoing R&D Efforts: CALICE silicon-tungsten ECal – 2 parallel efforts:  Technology.
SiD Cal R. Frey1 Some EGS Studies… Compare with Geant4  Questions of range/cutoff parameters EM Resolution understood? Moliere radius – readout gap relation.
19 March 2005 LCWS 05 M. Breidenbach 1 SiD Electronic Concepts SLAC –D. Freytag –G. Haller –J. Deng –mb Oregon –J. Brau –R. Frey –D. Strom BNL –V. Radeka.
Michele Faucci Giannelli TILC09, Tsukuba, 18 April 2009 SiW Electromagnetic Calorimeter Testbeam results.
SiD EMCal Testbeam Prototype M. Breidenbach for the SiD EMCal and Electronics Subsystems.
R Frey SiD at SLAC1 SiD ECal overview Physics (brief) Proposed technical solutions: silicon/tungsten  “traditional” Si sensors  MAPS Progress and Status.
KPiX - An Array of Self Triggered Charge Sensitive Cells Generating Digital Time and Amplitude Information Presented by Dietrich Freytag Stanford Linear.
SVX4 chip 4 SVX4 chips hybrid 4 chips hybridSilicon sensors Front side Back side Hybrid data with calibration charge injection for some channels IEEE Nuclear.
1 Si-W ECal with Integrated Readout Mani Tripathi University of California, Davis LCWS08 Chicago Nov 17, 2008.
Development of Particle Flow Calorimetry José Repond Argonne National Laboratory DPF meeting, Providence, RI August 8 – 13, 2011.
1 LumiCal Optimization and Design Takashi Maruyama SLAC SiD Workshop, Boulder, September 18, 2008.
SiD R&D on PFA and Calorimetry -> IDAG guidance. -> Present PFA situation. -> Developing a timeline for PFA development. -> Calorimetry aspects.
SiD Concept – R&D Needs Andy White U. Texas at Arlington SiD Concept Meeting LCWS06 Bangalore, India March 11, 2006.
Light Calibration System (LCS) Temperature & Voltage Dependence Option 2: Optical system Option 2: LED driver Calibration of the Hadronic Calorimeter Prototype.
Silicon-Tungsten EM Calorimeter R&D
26 Apr 2009Paul Dauncey1 Digital ECAL: Lecture 1 Paul Dauncey Imperial College London.
EUDET JRA3 ECAL and FEE C. de La Taille (LAL-Orsay) EUDET status meeting DESY 10 sep 2006.
Pion Showers in Highly Granular Calorimeters Jaroslav Cvach on behalf of the CALICE Collaboration Institute of Physics of the ASCR, Na Slovance 2, CZ -
KPiX - An Array of Self Triggered Charge Sensitive Cells Generating Digital Time and Amplitude Information Presented by Dietrich Freytag Stanford Linear.
SiD R&D tasks for the LOI - Subsystem R&D tasks - Summary of SiD R&D - Prioritization of R&D tasks -> Document for DoE/NSF ~Feb 2009 (Mainly based on Marty’s.
GLD-CAL and MPPC Based on talks by T. Takeshita and H. K. Kawagoe / Kobe-U 2005-Sep-16 MPPC
R Frey SiD ECal at ALCPG071 SiD ECal overview Physics requirements Proposed technical solutions: silicon/tungsten  “traditional” Si diodes  MAPS LOI.
1 R&D Advances: SiW Calorimeter LCWS 2010 Beijing SiD Concept Meeting March 28, 2010 John Jaros for SiD SiW Group (thanks to Ray, Ryan, Mani, and Marco.
- Performance Studies & Production of the LHCb Silicon Tracker Stefan Koestner (University Zurich) on behalf of the Silicon Tracker Collaboration IT -
SiD EMCal Testbeam Prototype M. Breidenbach for the SiD EMCal and Electronics Subsystems.
ILC Calorimetry Test Beam Status Lei Xia ANL HEP.
Rutherford Appleton Laboratory Particle Physics Department G. Villani CALICE MAPS Siena October th Topical Seminar on Innovative Particle and.
Application of Large Scale GEM for Digital Hadron Calorimetry Jae Yu For GEM DHCAL Group June 11, 2011 TIPP 2011 The Goals 30cmx30cm 2D readout with KPiX.
EMCal Sensor Status (* M. Breidenbach*,
July 7, 2008SLAC Annual Program ReviewPage 1 Silicon Tracking / Silicon Readout R&D Richard Partridge SLAC / Brown.
Individual Particle Reconstruction The PFA Approach to Detector Development for the ILC Steve Magill (ANL) Norman Graf, Ron Cassell (SLAC)
Silicon/Tungsten ECal for the SD Detector – Status and Progress R. Frey U. Oregon UT Arlington, Jan 10, 2003.
5 May 2006Paul Dauncey1 The ILC, CALICE and the ECAL Paul Dauncey Imperial College London.
Front-end Electronic for the CALICE ECAL Physic Prototype Christophe de La Taille Julien Fleury Gisèle Martin-Chassard Front-end Electronic for the CALICE.
A Forward Calorimeter (FoCal) as upgrade for the ALICE experiment at CERN S. Muhuri a, M. Reicher b and T. Tsuji c a Variable Energy Cyclotron Centre,
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
Durham TB R. Frey1 ECal R&D in N. America -- Test Beam Readiness/Plans Silicon-tungsten SLAC, Oregon, Brookhaven (SOB) Scintillator tiles – tungsten U.
SiW Electromagnetic Calorimeter - The EUDET Module Calorimeter R&D for the within the CALICE collaboration SiW Electromagnetic Calorimeter - The EUDET.
Thick-GEM sampling element for DHCAL: First beam tests & more
CEPC 数字强子量能器读出电子学预研进展
SiD Calorimeter R&D Collaboration
The ECal in the SiD LOI Overview of status and progress
A SiW EM Calorimeter for the Silicon Detector
detector development readout electronics interconnects bump bonding
Calorimetry for a CLIC experiment
   Calorimetry et al.    SUMMARY 12 contributions Tile HCAL
LCDRD ECal R&D Physics goals drive the design
SiD Electronic Concepts
A Silicon-Tungsten ECal for the SiD Concept
Simulation study for Forward Calorimeter in LHC-ALICE experiment
SiD Tracker Concepts M. Breidenbach
Steve Magill Steve Kuhlmann ANL/SLAC Motivation
LC Calorimeter Testbeam Requirements
Presentation transcript:

R Frey LCWS071 A Silicon-Tungsten ECal with Integrated Electronics for the ILC -- status Currently optimized for the SiD concept Baseline configuration: transverse seg.: 13 mm 2 pixels longitudinal: (20 x 5/7 X 0 ) + (10 x 10/7 X 0 )  17%/sqrt(E) 1 mm readout gaps  13 mm effective Moliere radius

R Frey LCWS072 Si/W ECal R&D Collaboration M. Breidenbach, D. Freytag, N. Graf, R. Herbst, G. Haller, J. Jaros Stanford Linear Accelerator Center J. Brau, R. Frey, D. Strom, undergraduates U. Oregon V. Radeka Brookhaven National Lab B. Holbrook, R. Lander, M. Tripathi UC Davis S. Adloff, F. Cadoux, J. Jacquemier, Y. Karyotakis LAPP Annecy KPiX readout chip downstream readout detector, cable development mechanical design and integration detector development readout electronics cable development bump bonding mechanical design and integration

R Frey LCWS073 Goals of the R&D Design a practical ECal which (1) meets (or exceeds) the stringent ILC physics requirements (2) with a technology that would actually work at the ILC. The physics case calls for a dense (small R m ), highly segmented “imaging calorimeter” with modest EM energy resolution  W-Si pixel sampling calorimeter The key to making this practical is a highly integrated electronic readout:  readout channel count = pixel count /  1000  cost  independent of cost for segmentation > 2-3 mm 3.6 mm is current default  allows for a small readout gap (1 mm)  small effective R m (13 mm)  low power budget (passive cooling)  handles the large dynamic range of energy depositions (few thousand) This takes some time to develop (getting close).

R Frey LCWS074 An “Imaging Calorimeter” A highly segmented (in 3-D) ECal provides a general pattern recognition capability: PFA: particle separation in jets id of specific objects/decays: e.g. tau tracking (charged and neutrals)

R Frey LCWS075 Segmentation requirement In general, we wish to resolve individual photons from jets, tau decays, etc. The resolving power depends on Moliere radius and segmentation. We want segmentation significantly smaller than R m Two EM-shower separability in LEP data with the OPAL Si-W LumCal (David Strom) :

R Frey LCWS076 Silicon detector layout and segmentation (KPiX) One KPiX readout chip for the sensor (1024 pixels, 6 inch wafer) KPiX also being considered for Si tracker and DHCal with GEMs Limit on seg. from chip power (  2 mm 2 ) Fully functional v1 prototype (Hamamatsu)

R Frey LCWS077 Critical parameter for R M is the gap between layers

R Frey LCWS078 Tungsten Si Detector KPix Kapton Kapton Data (digital) Cable Bump Bonds Metallization on detector from KPix to cable Thermal conduction adhesive Heat Flow readout gap cross section -- schematic Gap  1 mm

R Frey LCWS079 Data Concentrator “Longitudinal” Data Cable “Transverse” Data Cable Detectors Readout Chip “KPix” Tungsten Radiator Locating Pins Conceptual Schematic – Not to scale ~ 1m

R Frey LCWS0710 KPiX chip One channel of 1024 Si pixel Dynamic gain select Event trigger Leakage current subtraction calibration Storage until end of train. Pipeline depth presently is 4 13 bit A/D

R Frey LCWS0711 KPiX Cell 1 of channel prototypes: v1 delivered March 2006 v4 currently under test It’s a complicated beast – will need a v5 before going to the full 1024-channel chip

R Frey LCWS0712 Dynamic Range KPiX-2 prototype on the test bench Max signal: 500 GeV electron 1 MIP (4 fC)

R Frey LCWS0713 Power Passive conduction of 20 mW to module end (  75 cm) via the tungsten radiator results in a few  C temperature increase  OK !

R Frey LCWS0714 Noise in KPiX-4 1 MIP = 3.9 fC  meets ECal S/N spec of 8/1 outliers probably due to routing issues

R Frey LCWS0715 Noise is gaussian Can set threshold at  0.5 MIP Am

R Frey LCWS0716 prototype Si detector studies

R Frey LCWS0717 v2 Si detector – for full-depth test module 6 inch wafer mm 2 pixels improved trace layout near KPiX to reduce capacitance procurement in progress (it will take 6-12 months to complete the 40- wafer purchase – funding limited)

R Frey LCWS0718 Readout flex cable (digitized signals, power&control) First prototype:  2 stations  Buried signal layer between power and ground  Wire bond connections  No problem for prototypes For ECal:   6 stations: should be OK  Would like to determine length limit for next round (vias and multi- layers difficult for  1m)

R Frey LCWS0719 Status Summary and Plans (near term) KPiX readout chip  Currently studying v4 prototype (2x32 channels)  Submit v5 in next few weeks (4x32 channels) Improved biasing of MOS capacitors; new poser bus for comparators Optimized shaper time constants  Perhaps submit 1024-channel KPiX in Fall Silicon sensors  v2 prototype submitted to industry (40 sensors)  Schedule funding limited – hope to acquire sensors Fall-Winter Readout flex cable – short version for first module OK Bump bonding – first trials (UC Davis) just starting  All of the above: a full-depth, single-wafer wide module  Test in a beam: (1) electrons; (2) hadrons with HCal The R&D leading to an “ILC-ready” Si-W ECal technology is progressing well

R Frey LCWS0720 Extra stuff...

R Frey LCWS0721 R&D Milestones and test beams I.Connect (bump bond) prototype KPiX to prototype detector with associated readout cables, etc Would benefit from test beam (SLAC?) A “technical” test II. Fabricate a full-depth ECal module with detectors and KPiX-1024 readout – functionally  equivalent to the real detector Determine EM response in test beam – late Ideally a clean 1-30 GeV electron beam (SLAC?) III.Test with an HCal module in a hadron beam (FNAL?) – 2008-? Test/calibrate the hadron shower simulations; measure response IV.Pre-assembly tests of actual ECal modules in beam – >2010-?

R Frey LCWS0722 Compare two tungsten configurations: 30 layers x 5/7 X 0 (20 x 5/7 X 0 ) + (10 x 10/7 X 0 ) Longitudinal Sampling Resolution is 17% / √E, nearly the same for low energy (photons in jets) Better for the config. at the highest energies (leakage)  adopt as baseline

R Frey LCWS0723 Signals  <2000 e noise  Require MIPs with S/N > 7  Large dynamic range: Max. signal is  2500 MIPs (for 5mm pixels) Capacitance  Pixels: 5.7 pF  Traces: ~0.8 pF per pixel crossing  Crosstalk: 0.8 pF/Gain x Cin < 1% Resistance (traces)  300 ohm max Power  If < 40 mW/wafer  allows passive cooling (as long as power is cycled off between bunch trains) Provide fully digitized, zero suppressed outputs of charge and bx time on one ASIC for every wafer. Electronics requirements Use DC-coupled detectors: only two metal layers (cost)

R Frey LCWS0724 Response of Detectors to 60KeV Gamma's from Am 241 Possible ~1% wafer-wafer calibration?

R Frey LCWS0725 Noise is consistent with expectation from capacitance and series resistance