Ch.4 Air pollution Measurements, Emission Estimates.

Slides:



Advertisements
Similar presentations
OFFLINE COMPOSITION MEASURING SENSORS
Advertisements

Sampling and Measurement for Volatile Organic Compounds
HEAT EXCHANGER GUIDED BY: PREPARED BY:
Topical Aspects on Monitoring Airborne Radioactive Effluents from NPPs Wan-tae KIM.
Chapter 4 Mass and Energy Analysis of Control Volumes (Open Systems)
Air Pollution Chapter 5.
Environmental Engineering 343
Flame photometry.
LOCAL EXHAUST VENTILATION …study of the principles associated with proper application of local exhaust ventilation (LEV) for control of airborne contaminants.
Properties of Matter  What is Matter? ◦ Stuff that makes up everything in the universe  What are Properties of Matter? ◦ Hardness, texture, shape,
Section 1: What Causes Air Pollution?
The Nature of Liquids. A Model for Liquids According to the kinetic theory, both the particles that make up gases and liquids have motion. While particles.
ENERGY AUDIT INSTRUMENT
Ch.4 Air pollution Measurements, Emission Estimates.
Air Pollution Chapter 4.
Foundations of Chemistry
Air pollution Measurements and Emission Estimates Dr. Wesam Al Madhoun.
ACADs (08-006) Covered Keywords Suspended particulate matter, pollutants, SO 2, NO x, CI 2, H 2 S, NH 3, lapel. Description Supporting Material
Bioseparation Dr. Kamal E. M. Elkahlout Chapter 3 Mass transfer.
Air Chemistry GISAT 112. Scientific and Technical Concepts Phases of airborne matter- gases, particles Inorganic and organic chemicals Balancing chemical.
Introduction to Environmental Engineering
Topic 17: States of Matter Table of Contents Topic 17 Topic 17 Click box to view movie clip.
Russian Soot Measurement Methodologies Alexander Romanov Scientific Research Institute for atmospheric air protection St.Petersburg, Russian Federation.
1
Industrial Air Quality Monitoring. Sampling Protocols Grab vs. Integrated Personal vs. Area.
5. MASS AND ENERGY ANALYSIS OF CONTROL VOLUMES
1 CE Air Pollution Measurements, Emission Estimates Jeff Kuo, Ph.D., P.E.
Measurement of total mass concentration. 1. Sampling probe - Isokinetic or sampling from still air 2. Flow rate - Rotameter or digital flowmeter 3. Filter.
Matter Properties & Changes. __________ – anything that has mass and takes up space __________ - matter that has a uniform and unchanging composition…also.
Control Volume Analysis Using Energy
 Matter takes up space and has mass  Matter is made of atoms, usually chemically bonded into molecules  Exists in different states.
Air Pollution Solutions Ch. 18. How should we deal with air pollution? Legal, economic, and technical tools can help us to clean up air pollution, but.
Physical Science Matter
Pat Arnott, ATMS Air Quality Measurements, 25 Jan 2007 Basics: Do measurements of aerosol and gases at various locations on and near campus. Evaluate.
CHAPTER 5: Mass and Energy Analysis of Control Volumes
Chapter 13 - Analytical Instrumentation 1 Chapter 14 Analytical Instrumentation.
Changing State Mixing Materials Water Cycle Heating and Cooling Separating Solids Burning Materials Evaporation.
Chapter 4 Control Volume Analysis Using Energy. Learning Outcomes ►Distinguish between steady-state and transient analysis, ►Distinguishing between mass.
Urban Air Pollution GISAT 112. Learning Objectives Regions of the atmosphere Amount, composition of air we breathe Names of selected air pollutants Health.
25/04/2007INGAS Air Quality Improvement and Natural Gas Use in Istanbul Omar ALAGHA,PhD Fatih University, Department of Environmental Engineering,
Measuring Particle Pollution ITEP Air Quality Training Kodiak 2015
Matter Properties & Changes. __________ – anything that has mass and takes up space __________ - matter that has a uniform and Properties of Matter Substances.
Dr. Jason Roney Mechanical and Aerospace Engineering
1 Blend Times in Stirred Tanks Reacting Flows - Lecture 9 Instructor: André Bakker © André Bakker (2006)
Matter – Properties and Changes Chemistry – the study of matter and energy What is Matter?? What isn’t Matter??
Scrubbers Colloquium N. Maximova and the class. Puu
Chebatoris, A.W., Harvey, J.W., Hess, B.T., Krepps, J.P., O’Brien, K.A., Short, D.B., and Spaulding, R.E. Abstract Nitrogen dioxide is a criteria air pollutant.
HPLC.
Emission source sampling and monitoring Topic 6 Ms Sherina Kamal May
Matter Properties & Changes. __________ – anything that has mass and takes up space __________ - matter that has a uniform and unchanging composition…also.
Control Volume Analysis Using Energy
Chapter 5 MASS AND ENERGY ANALYSIS OF CONTROL VOLUMES
HW/Tutorial # 1 WRF Chapters 14-15; WWWR Chapters ID Chapters 1-2
Particle Pollution: It’s a Serious Concern. So small, you can’t see just one of them … Particle pollution is a complex mixture of extremely small particles.
1 Chapter 2 Steps in a chemical analysis Plan of analysis Before doing any quantitative analysis, the following questions should be answered: 1-
PG Spazzini – EMPIR Call 2016 meeting Metrology for Pollution Monitoring Pier Giorgio SPAZZINI INRIM.
Prof. Jiakuan Yang Huazhong University of Science and Technology Air Pollution Control Engineering.
U2 S3 L2 Titration page 603: Acid-Base Titration pages : Titration Step by Step page 838: Precision, Error and Accuracy Questions page 616: items.
2.14.  In 1970 the Environmental Protection Agency (EPA) was established  Required to set and enforce air quality standards  Air quality standard –
Ambient air sampling and monitoring Topic 5 Ms. Sherina Kamal.
Chapter 1: The Nature of Analytical Chemistry
Fundamentals of Analytical Chemistry Eighth Edition.
Energy measuring Instruments
Unit 42: Heat Transfer and Combustion
The Physics of the Lungs and Breathing
Presented by Harry C. Elinsky, Jr. Filtech, Inc.
Session 4: Air Pollution Measurements
ATMOSPHERIC AEROSOL: suspension of condensed-phase particles in air
Mass and Energy Analysis of Control Volumes (Open Systems)
AIR Quality Control Treatment of Emissions
Presentation transcript:

Ch.4 Air pollution Measurements, Emission Estimates

Types of measurements 1)Ambient measurement, Ambient Monitoring 2)Source measurement, source testing The principal Basis of Air pollution law in US Which depends on Air Quality standard philosophy is to have Air safe to breath This means that air quality should meet the NAQQS

To achieve that: Control and Monitoring of Air pollutants should be implemented To control pollutant concentrations The time, the place, and the amount of emissions, should be regulated Hence, The emission rates of various sources of air pollutants….must be regulated and measured

Why measurements are needed? 1) Legal Requirements 2) Evaluation of air pollution control devices Note: The control devices should be bought with Guarantee, and final payments should be after, demonstration that the device is installed,calibrated and in good performance situation.

In most air pollution control agencies the monitoring and source testing are done by different people, Whose different terminologies But all Air pollution measuring devices (ambient or source) have some or all of the various parts shown in the figure 4.1. WHAT IS THE AIM OF SAMPLING ?

The principal requirement of a sampling system is to obtain a sample that is representative of the atmosphere at a particular place and time and that can be evaluated as a mass or volume concentration The sampling system should not alter the chemical or physical characteristics of the sample in an undesirable manner

The major components of most sampling systems are 1) An inlet manifold 2) An Air mover 3) A collection medium 4 ) Flow measurement device

(1) The inlet manifold transports the material from the ambient atmosphere to the collection medium or analytical device in an unaltered condition, all inlet of ambient air must be rainproof (2) The air mover provides the force to create a vacuum or lower pressure at the end of the sampling system (pumps) (3) The collecting medium, may be solid or liquid sorbent for dissolving gases a filter surface for collecting particles or a chamber to contain an aliquot of air for analysis (4)The flow device measures the volume of air associated with the sampling system

A Representative sample In Air measurements there are two important problems 1)To obtain the suitable representative sample 2)The determination of the concentration of the pollutant of interest in it correctly which is harder 1-or-2? The representative ambient air sample has been the topic of legal and technical controversy How?

(1) The air inside the parking structure normally contains much more CO than the NAQQS (2) If the sample was taken from inside the parking structure, the result will show grate violation of NAAQS (3) If the sample is taken directly across the street from such a structure, in a most cases the concentration will be an order of magnitude less than inside the structure (4) A block away, the concentration will be even less (5) On the side walk directly adjacent to the structure, the concentration will be may twice as high as on the opposite side of the street.

Which of these locations is suitable for obtaining a sample of ambient air? Generally the ambient air sampler should be located at the place to which the public has free access where the pollutant concentration is highest This means that all indoor spaces, which the public has no access are excluded

Where we can put an ambient air monitor ? In Place: 1- has the power 2- shelter from rain and snow 3- constant temp. and pressure 4- easy access from monitoring personnel 5- protection from vandalism 6- if possible free rent place

In the previous case, the suitable place is the roof of county health building or of the county courthouse. However the concentration of the outer-related pollutants measured there is much lower than at street levels at the busiest intersection downtown. There are EPA guidelines for the proper placement of intake of air samples that are to represent ambient air. i.e. CO measurements must be made at street level, downtown. or in the same manner

In source testing: The representative sample problem is equally difficult 1- if the gas flow in large industrial smokestack is steady, well mixed across the diameter of the stack. It can be taken a representative sample any time and at any place. 2- most of such stacks have variation in velocities and concentrations from point to point, and from time to time. In this case, many separate measurements

Must be made and averaged.

Presumably, if one can went for enough down stream in this duct, one would find that the flow velocities and particle concentrations had become uniform. If one could do that, He should do that. But more typical sampling situation is shown in figure 4.4. In such ducts, one cannot find a place from downstream from any change of direction or other flow disturbance.

In newer plants, designers have sometimes considered the problems of obtaining a uniform gas flow and have provided access and a suitable location for the source sampler to place the required instruments.

4.2: Getting the representative sample to the detector -Many sampling instruments have some kind device on the inlet to exclude unwanted materials. i.e. - Insects sucked into a particulate sampler nozzle lead to erroneously high readings - Dust particles of less health concern that weigh more than all of the fine particles in the same air sample, which is of serious health concern.

Consistency between inlet excluding materials and modification of analysis. i.e. in table 2.3, EPA modified its particulate samplers in 1987 and in Before 1987, the sampler inlet was designed to exclude all particles larger than 50 micron, the quantity sampled was called Total Suspended particulate ( TSP). The 1987 modification changed the inlet to exclude all particles larger than 10 micron, the quantity sampled is called PM 10 (particulate matter 10 micron or smaller)

The 1997 modification changed the inlet again to exclude all particles larger than 2.5 micron. (PM 2.5 or smaller ). The 1997 modification also changed the flow rate. -In sampling device, gases may condense in the sampling device, or react with the solids encounter there. -Many combustion stack gases have a high water content and will condense on the walls of unheated sampling probe. In such cases, probes are normally heated to prevent this.

-Acid gases like SO 2 will react with alkaline solids on a filter, thus increasing the weight of solids on the filter. -If a grab sample is to be brought to the lab for analysis, the sample container should be from appropriate material and well pretreated according to the analyte type. i.e. even glass containers can react with some air pollutants.

4.3 Concentration Determination After sampling representatively and correctly, determination of analyte concentration is followed. For some pollutants, can be measured easily by real time instruments. Most of these operate optically, due to absorbance and transmittance at a particulate wavelength. i.e. Spectrophotometric methods.

The problem of interferences The interferences problem in air pollutants measurements is not trivial Even in the spectrophotometric methods, some interferences gases can be absorbed on the same wavelength. i.e. Measuring SO 2 gas in N 2 gas is easy, due to the reaction

SO 2 + 2NaOH → Na 2 SO 3 + H 2 O And measuring the change in NaOH concentration by simple acid base titration. However, if the problem is to measure SO 2 in air, CO 2 in the air will also react as the following reaction: CO 2 + 2NaOH → Na 2 CO 3 + H 2 O if CO 2 concentration in air in this case is steady and known, so a correction could be made in principle (but not in practice). But in the other cases, the interfering of the

other components may be not known. i.e. the US EPA adopted a new method for measuring NO2 and had to withdraw it, when became clear that the method was not adequately protected from such interferences. 4.4: Averaging Measuring ambient air quality with real time instruments, generally the average concentration over some period of time is given, i.e.

Average concentration = C avg = 1/∆t ∫c.dt C= the instantaneous concentration t= the time of measurement Most of real-time instruments present their results as an electronic signal that can be easily averaged by built-in electronics for any suitable chosen averaging time. The older instruments for gases as well as the current instruments, for particulate not real time instruments, but rather are averaging instruments.

For example: In EPA method for PM 2.5 sampling, it consists of: - Special inlet that exclude particles >2.5 micron in diameter -A filter -A fan -A flow measuring device -Suitable housing Collection is for 24 hrs

Average Concentration = increase in filter weight / air flow rate x ∆t Example 4.2: In the example 4.2: -- The sample size is small -The average value 21 µg/m 3 is 84% of the annual avg NAAQS. -Measured change in filter weight is 0.5 mg. -high quality weighing and sample humidity control is needed

-The resulting statistical errors percentages, can be high - The resulting measurements are upon 24 hours period, which means that this type of instruments is not suitable for determining hourly variations or trends as the real time instruments. Efforts to develop a suitable real time instruments for PM 2.5 have so far not been completely successful.

Older measuring schemes for gas pollutants have the principles of: 1-Reaction of known solution with the gaseous pollutant itself rather than the interferences 2- titration of the solution to determine the concentration of the gas N 1 V 1 = N 2 V 2 3- Or measuring the color of the solution, spectrophotometrically.

Many source devices use the cumulative measuring schemes For example: The EPA recommended sampling train for measuring the concentration of SO 2 gas in a stack

4.5 Standard Analytical Methods EPA has standard methods for various pollutants. (often one for source and other for ambient air) These methods define the pollutant. i.e. SO 2 is defined as the material which is detected by the SO 2 method shown in EPA STTANDARD METHODS FOR MAJOR AIR POLLUTANTS IN AMBIENT AIR (table 4.1)

However, in powerplant stack SO2 is defined as that material that is detected by (Method 6, Fig. 4.5) which is chemically quite different from the West Gaeke method.