Data Center Energy Efficiency Sonoma Mountain Village November 29, 2007 William Tschudi

Slides:



Advertisements
Similar presentations
Data Center Design Issues Bill Tschudi, LBNL
Advertisements

Introduction Build and impact metric data provided by the SGIG recipients convey the type and extent of technology deployment, as well as its effect on.
The Value of DOD Installation Energy Management Control Systems (EMCS) and Command Centers for Improved Operations and Increased Energy Efficiency Moderator:
Smart Devices. Smart Buildings. Smart Business The Potential for DCx Technology Enabled HVAC Operation Scot Duncan, P.E.
T OPPORTUNITIES FOR ENERGY EFFICIENCY AT TRIBAL GAMING FACILITIES.
Variable Frequency Drives VFD Basics
Using Benchmarking to Identify Energy Efficiency Opportunity in Cleanrooms; The Labs 21 Approach William Tschudi and Peter Rumsey June 29, 2004
Maximizing Your IT Budget through Energy Efficiency Heather Feigum Focus on Energy Advisor.
Cooling Product Positioning
ENERGY EFFICIENT DATA CENTRES – AN OVERVIEW Professor Peter James.
1 Page 1 Public Interest Energy Research (PIER) California Institute for Energy & Environment (CIEE) Lawrence Berkeley National Laboratory Bill Tschudi.
The Role of Tenant and Property Operations in Implementing Sustainable Practices Public Building Services October. 17, 2007 Om Taneja PBS Tenant and Property.
Katrina Pielli U.S. Environmental Protection Agency CHP Partnership
Energy Efficient Data Centers - an Update December, 2006 William Tschudi
24 x 7 Energy Efficiency February, 2007 William Tschudi
Reliability and Energy Efficiency – Not Mutually Exclusive
Creating Energy-Efficient Data Centers
Cutting the Green IT Hype: Fact vs. Fiction Kenneth G. Brill, Executive Director Uptime Institute Inc
Upstate Energy Expo 2010 NYSERDA Program Overview March 30, 2010 Cheryl Glanton, Project Manager.
Steve Craker K-12 Team Lead Geoff Overland IT and Data Center Focus on Energy Increase IT Budgets with Energy Efficiency.
Federal Data Center Consolidation Initiative Karen Petraska August 17, 2011.
Siemens sans siemens sans bold siemens sans italic siemens sans italic bold siemens sans black siemens black italic Siemens Building Technologies.
Enabling High Efficiency Power Supplies for Servers : Update on industry, government and utility initiatives Brian Griffith System Power Architect Intel.
Energy Efficiency Policy, Strategy and New Initiatives 15 th World Electronics Forum Meeting November 2009 | Shenzhen, CHINA.
Data Centers - They’re Back… E SOURCE Forum September, 2007 William Tschudi
Page 1 Public Interest Energy Research (PIER) California Institute for Energy & Environment (CIEE) Bill Tschudi Lawrence Berkeley National Laboratory
Air Conditioning and Computer Centre Power Efficiency The Reality Christophe Martel Tony Cass.
Mission Energy: Energy Efficient Cooling How Data Centre energy consumption and operating costs can be significantly reduced through readily available.
*Green City “Briefing” presentation to the City Council Summer 2008 GCGC GCGC * Project Location is confidential.
LBNL and Government Data Center Programs SC07 November, 2007 William Tschudi
1 DOE Data Center Energy Efficiency Program and Tool Strategy Paul Scheihing U.S. Department of Energy Office of Energy Efficiency and Renewable Energy.
Overview of LBNL’s High-Tech Buildings Project Activities Bill Tschudi and Tim Xu April 21, 2004
November 2004 Low Hanging Fruit Low Cost Energy Efficiency Opportunities in Cleanrooms.
Overview of Data Center Energy Use Bill Tschudi, LBNL
Bill Harrison Cleveland - Akron Chapters Joint Meeting March 16, 2009.
Federal Data Center Programs 7 X 24 Exchange October, 2007 William Tschudi
Electric Utility Perspective on the Water-Energy Nexus Jack Sahl, Director Environment and Resource Sustainability Southern California Edison August 28,
1 Data Center Energy Efficiency Metrics ASHRAE June 24, 2008 Bill Tschudi Lawrence Berkeley National Laboratory
50th HPC User Forum Emerging Trends in HPC September 9-11, 2013
The Data Center Challenge
Introduction to HVAC Optimization
Energy Efficient Data Centers Update on LBNL data center energy efficiency projects June 23, 2005 Bill Tschudi Lawrence Berkeley National Laboratory
Electrical Systems Efficiency Bill Tschudi, LBNL
1 CTO Challenge William Tschudi February 27, 2008.
Authors: William Tschudi, Lawrence Berkeley National Lab Stephen Fok, Pacific Gas and Electric Company Stephen Fok, Pacific Gas and Electric Company Presented.
Cleanrooms: Can They Be Energy Efficient? William Tschudi – LBNL Peter Rumsey – Rumsey Engineers November 4, 2004.
Datacenter Energy Efficiency Research: An Update Lawrence Berkeley National Laboratory Bill Tschudi July 29, 2004.
Optimizing Power and Data Center Resources Jim Sweeney Enterprise Solutions Consultant, GTSI.
1 Data Centers for the 21st Century Working with Industry to Improve Energy Efficiency in Data Centers Dale Sartor, P.E. LBNL Applications Team June 7,
1 Page 1 Steve Greenberg Sponsored by: Public Interest Energy Research (PIER) California Energy Commission and administered by California.
Data Center Energy Use, Metrics and Rating Systems Steve Greenberg Energy Management Engineer Environmental Energy Technologies Division Lawrence Berkeley.
CALIFORNIA ENERGY COMMISSION Why Peak Demand Offset Measures Are Necessary When There Is “Enough” Energy Lorraine White Advisory to Vice Chair Pfannenstiel.
All content in this presentation is protected – © 2008 American Power Conversion Corporation Row Cooling.
Insights into Google's PUE Results Spring Published Google PUE Results.
1 PCE 2.1: The Co-Relationship of Containment and CFDs Gordon Johnson Senior CFD Manager at Subzero Engineering CDCDP (Certified Data Center Design Professional)
1 Energy Efficient Data Centers: Strategies from the Save Energy Now Program Federal Environmental Symposium June 4, 2008 Dale Sartor Lawrence Berkeley.
Heat Network Demonstration SBRI: policy context & objectives for the competition Natalie Miles Heat Strategy and Policy (Heat Networks)
Data Center Energy Efficiency SC07 Birds of a Feather November, 2007 William Tschudi
Free Air Cooling for Data Centres
Massachusetts Clean Energy Center Budget Overview
Enabling High Efficient Power Supplies for Servers
From Lecture1 vi , ii vo , io Power Processor Controller Source Load
The Data Center Challenge
Electrical Systems Efficiency
HYDRONIC HVAC: The Most Comfortable and Efficient System
DOE Data Center Energy Efficiency Program and Tool Strategy
HYDRONIC HVAC: The Most Comfortable and Efficient System
Data Center Research Roadmap
Data Center Research Activities
Direct Current (DC) Data Center
Presentation transcript:

Data Center Energy Efficiency Sonoma Mountain Village November 29, 2007 William Tschudi

Acknowledgement of LBNL sponsors California Energy Commission – PIER program California Energy Commission – PIER program Pacific Gas and Electric Company Pacific Gas and Electric Company New York State Energy and Development Agency (NYSERDA) New York State Energy and Development Agency (NYSERDA) US - Environmental Protection Agency US - Environmental Protection Agency US – Department of Energy US – Department of Energy

Energy Commission 101 The state’s primary energy policy and planning agency charged with:  Licensing thermal power plants 50 megawatts and larger  Adopting appliance and building energy efficiency standards  Forecasting state energy use  Maintaining energy information and performing analysis  Proposing to the Governor integrated state energy policies  Conducting public interest energy research

PIER Program Established in California by legislation in 1997 Established in California by legislation in 1997 $62.5 million collected annually from investor-owned electricity utility ratepayers for “public interest” energy research, development and demonstration (RD&D) projects $62.5 million collected annually from investor-owned electricity utility ratepayers for “public interest” energy research, development and demonstration (RD&D) projects

PIER Program Objectives Improve energy cost/value Improve energy cost/value Improve environment, public health, and safety Improve environment, public health, and safety Improve electricity reliability/quality/sufficiency Improve electricity reliability/quality/sufficiency Strengthen the economy Strengthen the economy Provide consumer choice Provide consumer choice Address research gaps Address research gaps

PIER Segments of Research Buildings End-Use Energy Efficiency Buildings End-Use Energy Efficiency Energy-Related Environmental Research Energy-Related Environmental Research Energy Systems Integration Energy Systems Integration Environmentally-Preferred Advanced Generation Environmentally-Preferred Advanced Generation Industrial/Agricultural/Water End-Use Energy Efficiency Industrial/Agricultural/Water End-Use Energy Efficiency Renewable Energy Technologies Renewable Energy Technologies Climate Change Program Climate Change Program Transportation Research Transportation Research

Data Center research activities Research Roadmap Research Roadmap Benchmarking and 23 data center case studies Benchmarking and 23 data center case studies Self-benchmarking protocol Self-benchmarking protocol Power supply efficiency study Power supply efficiency study UPS systems efficiency study UPS systems efficiency study Standby generation losses Standby generation losses Performance metrics – Computation/watt Performance metrics – Computation/watt EPA report to Congress EPA report to Congress DOE Save Energy Now program DOE Save Energy Now program

Energy efficiency varies There are many features in data center design and operation that must all be optimized in order to achieve highest efficiency There are many features in data center design and operation that must all be optimized in order to achieve highest efficiency There is no silver bullet There is no silver bullet Changing paradigms may be necessary Changing paradigms may be necessary –DC power (Edison was right!) –Liquid cooling –Use of outside air for cooling

Server Load/ Computing Operations Cooling Equipment Power Conversion & Distribution Alternative Power Generation High voltage distribution Use of DC power Highly efficient UPS systems Efficient redundancy strategies Load management Server innovation Energy efficiency opportunities are everywhere Better air management Move to liquid cooling Optimized chilled-water plants Use of free cooling On-site generation Waste heat for cooling Use of renewable energy/fuel cells

Benchmark results helped to find best practices The ratio of IT equipment power to the total (or its inverse) is an indicator of relative overall efficiency. Examination of individual systems and components in the centers that performed well helped to identify best practices.

Ratio of electricity delivered to IT equipment Average.57 Higher is better Source: LBNL Benchmarking

Performance varies The relative percentages of the energy actually doing computing varies considerably.

Best HVAC Practices Air Management Air Management Air Economizers Air Economizers Humidification Control Humidification Control Centralized Air Handlers Centralized Air Handlers Low Pressure Drop Systems Low Pressure Drop Systems Fan Efficiency Fan Efficiency Cooling Plant Optimization Cooling Plant Optimization Water Side Economizer Water Side Economizer Variable Speed Chillers Variable Speed Chillers Variable Speed Pumping Variable Speed Pumping Direct Liquid Cooling Direct Liquid Cooling

Best Electrical Practices UPS systems UPS systems Self-generation Self-generation AC-DC distribution AC-DC distribution Standby generation Standby generation

Sonoma climate and efficiency Grapes aren’t the only thing that benefits from this climate Grapes aren’t the only thing that benefits from this climate Majority of cooling can be achieved without chillers Majority of cooling can be achieved without chillers

Most hours of the year can be cooled without chillers

LEED TM criteria and data centers The US Green Building Council established LEED criteria for commercial buildings The US Green Building Council established LEED criteria for commercial buildings Points are given for sustainable elements Points are given for sustainable elements –e.g. bikeracks, bamboo floors, waterless urinals While these are wonderful to consider for any building, the real action in data centers is with energy and water consumption While these are wonderful to consider for any building, the real action in data centers is with energy and water consumption A different point rating system is needed A different point rating system is needed

LEED TM type criteria points for data centers LBNL and industry are developing proposed criteria to be used in ranking data centers LBNL and industry are developing proposed criteria to be used in ranking data centers Consider different metrics: Consider different metrics: –Ratio of IT power to total power –Efficiency of power delivery –Efficiency of chilled water plant –Air management effectiveness –Environmental conditions –Mission of the data center –etc. Completion planned for August, 2008 Completion planned for August, 2008

LEED TM type criteria development Green Grid, Uptime Institute, ASHRAE, Critical Facilities Roundtable Green Grid, Uptime Institute, ASHRAE, Critical Facilities Roundtable EPA and DOE supportive EPA and DOE supportive Other industry input welcome Other industry input welcome

LBNL data center demonstrations “Air management” demonstration Outside air economizer demonstration Use of infrared thermography DC powering demonstration Silicon Valley Leadership Group – “chill-off”

Measured fan energy savings – 75% If mixing of cold supply air with hot return air can be eliminated- fan speed can be reduced

Better temperature control can allow raising the temperature in the entire data center! ASHRAE Recommended Range Ranges during demonstration

See the problem areas Infrared thermography and CFD modeling can be used as visualization tools

Inverter InOut Bypass Battery/Charger Rectifier Internal Drive External Drive I/O Memory Controller  Processor SDRAM Graphics Controller DC/DC AC/DC DC/DC AC/DC Multi output PS Voltage Regulator Modules 5V 12V 3.3V 12V 1.5/2. 5V 1.1V- 1.85V 3.3V 12V PWM/PFC Switcher Unregulated DC To Multi Output Regulated DC Voltages Data center power conversions AC voltage conversions

With over 25 industry partners direct DC powering of servers was demonstrated

Typical AC distribution today 480 Volt AC

Facility-level DC distribution 380V.DC 480 Volt AC

AC system loss compared to DC AC system loss compared to DC 7-7.3% measured improvement 2-5% measured improvement Rotary UPS

Challenge Can Sonoma Mountain Village’s data center demonstrate these energy saving technologies? Can Sonoma Mountain Village’s data center demonstrate these energy saving technologies? LBNL is seeking partnering sites to demonstrate DC power LBNL is seeking partnering sites to demonstrate DC power

Thank you website: