GIF++ gas systems 11/07/2014Ernesto, Roberto PH-DT-DI gas service1.

Slides:



Advertisements
Similar presentations
ALICE TPC Ne/CO2 Gas System. Mixing Rack CO 2 -Removal & (O 2,H 2 O)- Cleaning Rack.
Advertisements

André Augustinus 16 June 2003 DCS Workshop Safety.
1 Monitor of Isobutane Content in the RPC Gas Mixture Changguo Lu, Kirk McDonald Princeton University (10/22/2008)
The RPC Closed loop Gas System. Schedule for completion - update Status Supplier: ok Mixer: ok Humidifier: ok Purifiers: installed, but not completely.
Status of the LHCb RPC detector Changes with respect to Note cm strips instead of 3 cm (cost optimization) All gaps same size (standardization)
1 May 6, 2009 C. Lu Continuously Monitoring the RPC Gas Mixture with a Gas Chromatograph C. Lu Princeton University.
1 May 6, 2009 C. Lu Continuously Monitoring the RPC Gas Mixture with a Gas Chromatograph C. Lu Princeton University.
Plans for the Muon Gas and Cooling Systems LHCb infrastructure workshop February Burkhard Schmidt, with important input from Roberto Guida and Beatrice.
Daya Bay Muon Subsystem Review, 7/28-29/2007, IHEP, Beijing Daya Bay RPC Gas System: Design Report & Budget Estimate Changguo Lu, Kirk McDonald Princeton.
RD51 Common Test Beam: Status RD51 collaboration week Kolymbari, June 2009 Yorgos Tsipolitis NTUA.
Gas systems for GIF++ 14/02/2015 Ernesto Regaño 1.
Fire Detection Presentation
Yiftah Silver Tel Aviv University September 27 th 2012.
02/07/2014R. Guida CERN/PH-DT-DI1 RPC R&D Collaboration PH-DT Topics of Interest Studies of gas systems performance and development of dedicated gas modules.
Point 5 - Cooling Network - Key Primary Water Chilled Water Mixed Water Eau Bruite Standard Power Diesel Backup Comp Air Primary Water at 20-25C – Produced.
May Exp-Area meeting1 Safety Systems Installation status Flammable Gas Detection System Fire Detection System in SG8 ODH Detection System CO2 Detection.
European Organization for Nuclear Research LHC Gas Control System Applications G.Thomas, J.Ortola Vidal, J.Rochez EN-ICE Workshop 23 April 2009.
TB Peter Glässel, Heidelberg1 TPC Progress Project leader: Peter Braun-Munzinger, GSI Darmstadt Deputy project leader: Johanna Stachel, Heidelberg.
GIF++ gas systems 21/01/2014Ernesto, Roberto PH-DT-DI gas service1.
FUNCTIONAL SPECIFICATION Dorothea Pfeiffer Dennis Haasler GIF++ User Meeting
CMS Muon Chambers Long term studies at GIF++ Andrey Marinov On Behalf of Long Term Studies of the CMS Muon Detectors 1.
Gas Coordination Panel 24/08/2004 Flammable Gas Installation Requirements, Interlocks, etc. F.H.
Tariq J. Solaija, NCP Forward RPC EDR, Tariq Solaija Forward RPC EDR The Standard RPC for low  regions Tariq J. Solaija National Centre for.
Calliope ENEA Casaccia MON = monitor MWPC (CH1) T1 = test MWPC (CH3) T2 = test MWPC (BTF,CERN1,CERN2) T = temperature sensor P = atmospheric.
First results of an aging test of a full scale MWPC prototype for the LHCb muon system Workshop on “Aging Phenomena in Gaseous Detectors”, October 2-5.
TOF Gas System Project Overview. Content Prototype for Aging tests done for RPC’s TOF Gas System: parameters and module layouts. Special Technology: channel.
GIF in EHN1- layout, construction and schedule Adrian Fabich, EN-MEF-LE GIF users meeting, 12 th February 2014.
Yiftah Silver Tel Aviv University September 27 th 2012.
The RPC Closed loop Gas System Slides from Bianco and Guida.
Gas Systems for Particle Detectors R.Guida on behalf of the PH-DT-DI/Gas Service Team PH-DT Seminar CERN September 4 th, 2014.
ALICE-TRD gas system 1/4/2015R. Guida PH-DT-DI1. TRD gas system Few numbers:  Total number of modules/racks: 20 (max leak rate certified at construction.
G. Pugliese RPC requests for GIF++ G.Pugliese, N. Zaganidis and I. Pedraza on behalf of the RPC group 1.
Test beam setup: status report 31/03/2009 M. Alfonsi (CERN)
CMS Muon detectors for the GIF++ DRAFT Needs discussion within CMS Muon community A. Sharma.
Ion Sources – Hardware and Operation MACS Week Friday 8th October 2010 PP a-LPE, 8 th October 2010, MACS Week 2 Liviu Penescu, „Ion Sources.
GIF++ Control System (GCS) Gilles MAIRE PH-DT-DI1.
STATUS REPORT WP7 Facilities and Component Analysis for Detector R&D Activities and Status Resources and Expenditures Work plan Mar CAPEANS 3/11/08 M.C.
Large-Area GEM Detector Development at CMS, RD51, and Fl. Tech – A brief overview – Marcus Hohlmann Florida Institute of Technology, Melbourne, FL PHENIX.
Results from the CMS-RPC tests at CERN Gamma Irradiation Facility Roberto Guida CMS-RPC (Bari, Beijing, Napoli, Pavia, Sofia) Seoul, October 2005.
Atlas Gas Systems - CPC6 Upgrade and Re-Commissioning Infrastructure Meeting – 8th January 2014 Steve Pavis PH-DT-DI/Gas.
February 14, Comprehensive Review B. Schmidt Outline: Status and overview of activities: –Platforms and staircases –Muon Filters and beam plugs.
26/03/2014L-Ph. DE MENEZES & F. MERLET CERN/PH-DT-DI New recuperation system for n-Pentane:  Installation of the module in parallel of the first.
European Organization for Nuclear Research LHC Gas Control System Applications Generation to Deployment phases Strategy/Principles.
25/04/2014R. Guida, A. Wasem PH-DT-DI Gas1 Outline ALICE gas systems meeting Outline Introduction Review usage of ALICE gas M&O 2013 Review achievements.
Overview on the Proposal for a new Gamma Irradiation Facility at CERN GIF++ Mar CAPEANS April 29 th, 2009 April 29, 091M.C.
8/4/2015R. Guida PH-DT-DI1 Info 1)Air conditioning system Status: Adrian Fabich contacted CV and he is waiting for info. Today I’m going to meet experts.
CMS-GEM gas system GEMs for CMS High Eta Muons - Workshop III, CERN April R.Guida PH-DT-DI.
Gas system for NA62 Straw detector Roberto Guida On behalf of Gas Service Team NA62 Straw working meeting, March 26, 2012 Outline: P&I Drawing Schedule.
The closed loop system at ISR We moved the system at ISR in January. Preliminary tests has been done in order to verify the possible use in the “ISR conditions”:
Totem Gas Systems ( T1, T2 ) F. Hahn and S. Haider PH / DT1.
External Data and DIP Oliver Holme 18 th January 2008.
GIF++ gas system Outline:  Beam and cosmic trigger  Gas distribution panels  Gas detection (present and final layout)  Conclusions 14/1/2015R. Guida,
Status of GIF++ Adrian Fabich, Dorothea Pfeiffer, EN-MEF-LE EATM, 27th August 2013.
Aachen Status Report: CO 2 Cooling for the CMS Tracker at SLHC Lutz Feld, Waclaw Karpinski, Jennifer Merz and Michael Wlochal RWTH Aachen University, 1.
The (prototype) C&V Framework component used for the SPD Cooling Control A.Tauro, G.De Cataldo.
GIF++ The new Gamma Irradiation Facility at CERN Physics Department Detector Technology Group 25/07/12 Project #4R. Fortin PH-DT-DI1 Status of procurement:
GIF++ implementation Adrian Fabich, Sylvain Girod, Dorothea Pfeiffer, EN-MEF-LE GIF++ 3rd users’ meeting, 11th July 2013.
Gamma Irradiation Facility RFortin_ PH-DT-DI GIF Users Meeting April 30, 2009 Richard G. Fortin 1 / 10 Upgrading to a GIF++
GIF completion status Adrian Fabich, EN-MEF-LE on behalf of the GIF project team GIF users meeting, 14 th January 2015.
CMS – RPC GIF++ G. Pugliese on behalf of the RPC Collaboration 1.
GIF++ implementation Adrian Fabich, Sylvain Girod, EN-MEF-LE Technical meeting with Supplier of Irradiator, 3 rd October 2013.
Status of Gas Barrack(SPS) and Exhaust JAILLET David EN/EA/CT.
The Next Generation of a Gamma Irradiation Facility GIF++
Totem Gas Systems ( T1 , T2 ) S. Haider PH / DT1.
RD51-WG X June test beam experience: useful information for October
Gas System Commissioning
Gas for World wide RPCs Ian Crotty 12 Feb 2015.
R. Guida PH-DT-DI Boston Students Program CERN, 16/1/2013
352MHz Klystron Control for the 3MeV Linac test stand
Presentation transcript:

GIF++ gas systems 11/07/2014Ernesto, Roberto PH-DT-DI gas service1

 neutral gases: tot 9 lines ▫Ar, CO2, N2, He, SF6, CF4 and 3 spare pipes ▫Distribution panels: 4 gas service area + 1 preparation zone  flammable gases or gases with very low vapour pressure: tot 6 lines ▫iC4H10, CH4, Ar/H2(optional), C2H2F4 and 2 spares. Lines and room heated. ▫Distribution panels: 1 gas service area (flammable gases)  1 normal exhaust  1 exhaust for potentially flammable mixtures 11/07/2014Ernesto, Roberto PH-DT-DI gas service2 Gas supply

 At full capacity the gas mixing zone will contain ▫6 mixing racks ▫3 closed loop gas systems ▫2 analysis racks ▫1 control rack ▫5 spare racks  Gas analysis: ▫1 O2 and H2O analysis rack (LHC design: automatic scan between all gas streams selected. ▫Gas chromatograph will be integrated in the O2-H2O analysis rack. ▫1 Infrared analysis rack for monitoring iC4H10 concentration in cosmic trigger. ▫Hardwired interlock signal to stop the system will be send in case problem (DSS) 11/07/2014Ernesto, Roberto PH-DT-DI gas service3 Gas service area

 Start-up version: ▫2 mixing racks (cosmic and beam trigger) ▫1 closed loop gas systems (cosmic trigger ?) ▫2 analysis racks ▫1 control rack 11/07/2014Ernesto, Roberto PH-DT-DI gas service4 Gas service area Construction procedure/design as for LHC gas systems

Gas mixture distribution: Each distribution panel: 6 supply (outer diameter 8 mm) and 6 return (outer diameter 10 mm). The gas distribution is divided in: ▫ panels for neutral mixtures (type A) ▫ panels for mixtures that might contain flammable gases (type B). Gas service area ▫6 panels type A ▫2 panels type B Irradiation bunker ▫6 panels type A ▫2 panels type B Preparation area ▫3 panels type A ▫1 panels type B 11/07/2014Ernesto, Roberto PH-DT-DI gas service5 Gas mix distribution Construction on-going

11/07/2014Ernesto, Roberto PH-DT-DI gas service6 Gas mixers  Remote control and monitoring.  All info available on DIP through GCS and G pp CS

11/07/2014Ernesto, Roberto PH-DT-DI gas service7 Gas distribution panels

Gas supply panel neutral gases 80 cm x 40 cm x 35 cm IR CL2CL1CL3 Spare sup Gas supply panel flammable gases 80 cm x 40 cm x 35 cm sup 11/07/2014Ernesto, Roberto PH-DT-DI gas service8 mix sup Mix1Mix2 AnalCtrl Mix3 Spare sup Spare mix RPC1RPC2 TGC1 Spare sup mix Mixture distribution panels 60 cm x 30 cm x 35 cm Gas service zone – final layout iC4H10, R134a, SF6 nC5H12, CH4, CO2 Detection nC5H12 Detection CH4 Detection iC4H10

Gas supply panel neutral gases 80 cm x 40 cm x 35 cm IR CL2CL1CL3 Spare sup Gas supply panel flammable gases 80 cm x 40 cm x 35 cm sup 11/07/2014Ernesto, Roberto PH-DT-DI gas service9 mix sup Mix1Mix2 AnalCtrl Mix3 Spare sup Spare mix RPC1RPC2 TGC1 Spare sup mix Mixture distribution panels 60 cm x 30 cm x 35 cm Gas service zone – by October iC4H10, R134a, SF6 nC5H12, CH4, CO2 Detection nC5H12 Detection CH4 Detection iC4H10

11/07/2014Ernesto, Roberto PH-DT-DI gas service10 mix sup Preparation zone– final layout iC4H10, nC5H12 Detection nC5H12 Detection CH4 Detection iC4H10 Mobile head

11/07/2014Ernesto, Roberto PH-DT-DI gas service11 mix sup Preparation zone– by October iC4H10, nC5H12 Detection nC5H12 Detection CH4 Detection iC4H10 Mobile head

11/07/2014Ernesto, Roberto PH-DT-DI gas service12 Irradiation bunker– final layout TGC – nC5H12 iC4H10, nC5H12, CH4, R134a, SF6 iC4H10, nC5H12, CH4, R134a, SF6 Detection nC5H12 Detection CH4 Detection iC4H10 Mobile head

11/07/2014Ernesto, Roberto PH-DT-DI gas service13 Irradiation bunker TGC – nC5H12 iC4H10, nC5H12, CH4, R134a, SF6 iC4H10, nC5H12, CH4, R134a, SF6 Detection nC5H12 Detection CH4 Detection iC4H10 Mobile head

11/07/2014Ernesto, Roberto PH-DT-DI gas service14 Conclusions – start-up version First version to start-up the facility: 1.20 distribution panels 2.Simplified version of control rack (basic functionality like connection to remote pvss interface for recording flows, gas systems status, …) 3.2 gas mixing racks for the fixed installations (beam and cosmic trigger setups). Any additional mixer for users will cost about 15 kCHF (not included in the present list). 4.1 IR analysis rack (needed to operate cosmic trigger gas system). 5.1 analysis rack (O2+H2O+ gas chromatograph). 6.1 closed loop gas system.

R. Guida CERN/PH-DT-DI15 Small recirculation systems Two small systems developed:  Prototype used at GIF (2003)  New simplified version for lab R&D ( ) 26/6/2014

11/07/2014Ernesto, Roberto PH-DT-DI gas service16 Gas systems – future upgrades Many possibilities for future upgrades to be discussed with users for resources: 1.Upgrade control rack for more units (mixers, analysis, re-circulation systems, … ) 2.Additional IR analysis rack for second mixer using flammable gas 3.3 mixers for users (15 kCHF each) 4.3 new gas recirculation systems for users 5.Install more distribution panels (?)