BACKBONE SUBSYSTEM. CABLING SYSTEM Backbone Subsystem The Backbone cabling subsystem is based on cabling segments, which link such connection centers.

Slides:



Advertisements
Similar presentations
Lecture#04 Plain Old Telephone Service (part II) The Bonch-Bruevich Saint-Petersburg State University of Telecommunications Series of lectures Telecommunication.
Advertisements

Chapter 4 Computer Networks
Cabling system components
Network Design Issues Design and Documentation Prepared by: Aline L. Mendoza.
Telecommunication Rooms
Chapter 3: Planning a Network Upgrade
Antonio González Torres
Telecom Cabling Grounding and bonding.
1 Structured Backbone Design of Computer Networks.
Cabling Structured Cabling Standards
Physical Transmission Media 8 5/9/ Modified by: Brierley.
Physical and Network Topology Security
TIA-1005 (Proposed by TR-42.9) Industrial Cabling Standard Pete Lockhart Anixter Manufacturing IT Forum Cleveland, Ohio May 20-21, 2008.
Infrastructure and components. Cable The cable and components used in structured cabling systems is defined in the standards –EIA/TIA 568 x There are.
111 © 2002, Cisco Systems, Inc. All rights reserved. Trim out phase steps Cutting cables to length Labeling cables Dressing cables Terminating cables Installing.
Classes of transmission media
1 Version 3.0 Module 3 Networking Media. 2 Version 3.0 Cable Specifications Cables have different specifications and expectations pertaining to performance:
NETWORK DESIGN Customer requirements Network topologies Cable choice Hardware TSB 75 TSB72.
Designing and Implementing Cabling Infrastructure Dr. Saif al Zahir King Fahd University of Petroleum & Minerals Computer Engineering Department Dr. Saif.
Structured Cabling Overview
Copyright CCNA 1 Chapter 6, Part 1 Ethernet Technologies By Your Name.
1 Fiber Optics FIBER OPTIC PATCH PANELS. 2 Fiber Optics Just like our copper cable plant the fiber cable plant incorporates many of the same hardware.
Computer Communication & Networks
Many Roads To Home. LAN Roads UTP STP Coaxial Fiber Optics.
Innovative Ways To Make Cost Effective LANs for K-12 Schools
1 PBX installation considerations BASIC TELECOMMUNICATIONS.
Design Considerations for Telecommunications Pathways and Spaces
CSE 550 Computer Network Design Dr. Mohammed H. Sqalli COE, KFUPM Spring 2007 (Term 062)
SPLICING OF FIBER CABLE
Computer Communications and Networking (CCN)
Hardware Concepts Chapter 4.
Chapter 4: Computer Networks Department of Computer Science Foundation Year Program Umm Alqura University, Makkah Computer Skills /1436.
Signamax Structured Cabling Seminar. INTRODUCTION.
The Saigon CTT Semester 1 CHAPTER 5 Le Chi Trung.
HORIZONTAL SUBSYSTEM. CABLING SYSTEM Horizontal Subsystem The Horizontal cabling subsystem is the part of the Signamax Cabling System that extends from.
1 Guide to Network Cabling Fundamentals Chapter 5.
Siposs Arnold Konrad Computer Networks Coordonator: Mr. Dr. Z. Pólkowski.
CABLING SYSTEM INSTALLATION. Installation Quality The quality of installation is the most serious problem in implementation of the telecommunications.
SIGNAMAX CABLING SYSTEM COMPONENTS. TRANSMISSION MEDIA Twisted Pair.
CABLING SYSTEM BACKBONE SUBSYSTEM.
ANSI/TIA-568-C Generic Telecommunications Cabling APPROVED: FEBRUARY 2, 2009 This template can be used as a starter file for presenting training.
CABLING SYSTEM INSTALLATION. Installation Quality The quality of installation is the most serious problem in implementation of the telecommunications.
SIGNAMAX CABLING SYSTEM COMPONENTS. TRANSMISSION MEDIA Twisted Pair.
Jim Van Dyke Network Engineering & Technology Section The UCAR Physical Network Infrastructure or Why Bother to Do It Right? Presented By: James R. Van.
CABLING SYSTEM ADMINISTRATION. Administration Concept.
SIGNAMAX WARRANTY SYSTEM. Signamax Warranty Types Signamax Connectivity Systems offers its customers a versatile system of component and system warranties.
CABLING SYSTEM INSTALLATION. Installation Quality The quality of installation is the most serious problem in implementation of the telecommunications.
SIGNAMAX CABLING SYSTEM. Signamax Cabling System The Signamax Cabling System Design Principles and Installation Practices are based on the requirements.
Signamax™ Cabling System Review Revision E. INTRODUCTION.
Gary Marret, RCDD WHAT IS ETHERNET? WHAT IS ETHERNET? WHAT IS ETHERNET/IP? WHAT IS ETHERNET/IP? ETHERNET HARDWARE? ETHERNET HARDWARE? HOW DO I CABLE.
COPPER AND FIBER REVIEW
TELECOMMUNICATIONS SPACES. WORK AREA WA Work Area Work Area (WA) Telecommunications Outlet (TO) Horizontal subsystem cables Equipment and patch cords.
TELECOMMUNICATIONS SPACES
Ipswich City Precinct. 6. ICC Precinct Installation Standards & Regulatory Compliance ICT Infrastructure Integration & Convergence 1. Pit & Pipe Underground.
Transmission Media. Characteristics to consider for Media Selection Throughput Cost Installation Maintenance Obsolescence vs bleeding edge Support Life.
CABLING SYSTEM PROTECTION. Screening/Shielding  1 In the Signamax Cabling System for the efficient screening of the telecommunications systems, the screen.
CABLING SYSTEM CERTIFICATION TESTING. TWISTED-PAIR CABLING TESTING.
SIGNAMAX CABLING SYSTEM. Signamax Cabling System The Signamax Cabling System Design Principles and Installation Practices are based on the requirements.
NETWORKING MEDIA b Shielded twisted-pair - 2 pair, 150 ohm b unshielded-twisted pair - 4 pair, 100 ohm b fiber optic cable - 2 fibers b coaxial cable -
COMMUNICATION SYSTEMS IN BUILDINGS/CAMPUSES
LECTURE#6 - CABLES Asma AlOsaimi. Copper Coaxial Cable - Thick or Thin Unshielded Twisted Pair - CAT 3,4,5,5e&6 Optical Fiber Multimode Singlemode Wireless.
Data centre network map
Ch 3 Fiber Optics Technician’s Manual, 3rd. Ed Jim Hayes
INTRODUCTION TO NETWORK CABLING
Ch 7 Fiber Optics Technician’s Manual, 3rd. Ed Jim Hayes
Module 5 - Switches CCNA 3 version 3.0.
Horizontal and Back Bone Cabling
Computer Networking A computer network, often simply referred to as a network, is a collection of computers and devices connected by communications channels.
Computer Systems Department.  Introduction  Course Objectives  Grading Policy  Lab Policy  Structured Cabling.
Presentation transcript:

BACKBONE SUBSYSTEM

CABLING SYSTEM

Backbone Subsystem The Backbone cabling subsystem is based on cabling segments, which link such connection centers as Main Cross-Connect, Intermediate Cross-connects, and Horizontal Cross-connects. In these centers Backbone subsystem links are connected with each other thereby forming Backbone subsystem channels that are used to distribute telecommunications services (voice, data, image, etc) to the Horizontal cabling subsystem Backbone cabling subsystem also includes cabling between buildings

Backbone Subsystem The Backbone cabling subsystem consists of the following elements: –Main Cross-connect (MC) –Intermediate Cross-connect(s) (IC) –Horizontal Cross-connect(s) (HC) –Level I Backbone subsystem connecting MC with IC(s) or with HC(s) –Level II Backbone subsystem connecting IC(s) with HC(s) –Backbone cabling segments connecting Entrance Facility (EF) with MC or with IC(s) –Patch cords connecting the segments of the Backbone subsystem in the MC and IC(s)

Backbone Subsystem

Topology The Backbone cabling subsystem has a star topology with two hierarchy levels Each IC is connected with the MC by means of Level I Backbone subsystem. All links come together in the MC, thereby forming a star. This is the first level of the hierarchy. Each HC in its turn is linked with the IC by the Level II Backbone subsystem also forming a star with a single center in the MC. This is the second level of the hierarchy

Cross- and Interconnection In the Main Cross-connect and Intermediate Cross-connects two methods of connecting active equipment to the Backbone cabling subsystem and one method for passive connection between cable segments of the Backbone cabling subsystem are used More details on cross- and interconnection methods are given in “HORIZONTAL SUBSYSTEM” section

Design Rules The Backbone cabling subsystem can have only one MC

Design Rules All HCs are connected with the MC directly or via ICs

Design When choosing a layout and designing Backbone cabling subsystem the following factors should be taken into consideration: –The backbone cabling is expected to serve the needs of building occupants for one or several planning periods, each period spanning three to ten years –During each planning period, the backbone cabling design should accommodate growth and changes in service requirements without the installation of additional cabling. The length of the planning period should be based upon the stability and growth of the end user organization continued on next slide

Design –It is generally not possible or economically viable to install backbone cabling for the entire life of the generic cabling system Instead the design may be based on current or foreseeable application requirements Such short-term selection criteria is often appropriate for building backbone cabling where there is good physical access to pathways continued on next slide

Design –The selection of campus backbone cabling may require a longer term approach than that adopted for the building backbone, particularly if access to pathways is more limited This limitation shall be taken into consideration when choosing inter-building Backbone cabling subsystem planning period (usually, longer planning periods are used) –Each recognized cable has individual characteristics that make it useful in a variety of situations A single cable type may not satisfy all end user requirements. The campus backbone cabling should contain the mix of cabling media and cable types necessary to support the desired applications continued on next slide

Design –When future service requirements are not well defined, use "worst case" scenarios when evaluating different backbone cabling alternatives The higher the uncertainty, the more flexible the backbone cabling system needs to be –When designing Backbone subsystem pathways and cross- connects special attention should be paid to relative position of EMI sources to the telecommunications cabling

Transmission Media The following types of transmission media are allowed in the Backbone cabling subsystem of the Signamax Cabling System: –category 5e, 6, and 6a four-pair 100-Ohm unscreened cables –category 5e, 6, and 6a four-pair 100-Ohm screened cables –category 3 and 5 multipair 100-Ohm unscreened cables –category 3 and 5 multipair 100-Ohm screened cables –50/125 µm optical fiber multimode cables –62.5/125 µm optical fiber multimode cables –9/125 µm optical fiber singlemode cables

Distances The maximum supportable distances in the Backbone cabling subsystem are application and media dependent Specific applications may exist, or become available in the future, that do not operate over the maximum distances specified for the Backbone cabling subsystem The Signamax Cabling System designers are advised to consult the specific standards associated with the planned service, or equipment manufacturers and systems integrators to determine the suitability of the cabling for specific applications

Distances  11 Maximum allowable distances in the Backbone cabling subsystem of the Signamax Cabling System shall be limited by the specifications of anticipated telecommunications applications, provided the cabling system stays within the boundaries of the end-user premises. Category 5e, 6, and 6A twisted-pair transmission media between MC and HC, IC and HC, or MC and IC if the Backbone cabling subsystem is meant to support high data rate applications (with operation frequency range over 1 MHz) shall be limited by 100 m (328 ft).

Cord Length  12 Total length of category 5e, 6, or 6A twisted-pair equipment and patch cords in MC, IC, or HC shall be limited by 5 m (16 ft) in one Cross-connect and 10 m (33 ft) in both, if the Backbone cabling subsystem is meant to support high-speed applications (with operation frequency range over 1 MHz) continued on next slide

Cord Length  12 Total length of twisted-pair equipment and patch cords in MC, IC, or HC shall be limited by the distance specifications of anticipated telecommunications applications taking into account 0.2 length de-rating factor for 24-AWG cables and 0.5 length de-rating factor for 26-AWG cables if the Backbone cabling subsystem is meant to support low-speed applications (with operation frequency range up to 1 MHz) continued on next slide

Cord Length  12 Total length of optical fiber equipment and patch cords in MC, IC, or HC shall be limited by the distance specifications of anticipated telecommunications applications

Cord Length  5 To enable convenient connection of active equipment and increase flexibility, in the Backbone cabling subsystem aimed to support high-speed applications (with operation frequency range over 1 MHz), the total length of equipment and patch cords in Cross-connects may be increased up to 25 m (82 ft) for 24-AWG cords 20 m (66 ft) for 26-AWG cords, if the fixed cable length is not more than 70 m (230 ft)

TELECOMMUNICATIONS PATHWAYS AND SPACES

Pathways and Spaces Backbone pathways consist of intra- and interbuilding pathways Backbone pathways may be either vertical or horizontal Interbuilding backbone pathways extend between buildings Intrabuilding backbone pathways are contained within a building

Pathways and Spaces One or more backbone facilities may exist within a building A backbone facility is generally formed by vertically stacking teecommunications closets with floor openings between them Tie pathways may also exist to install backbone media between telecommunications closets on the same floor

Pathways and Spaces Intra-building Backbone pathways encompass: –Underfloor pathways –Access floor –Conduit –Tray and wireway –Ceiling pathways –Perimeter pathways –Furniture pathways

Pathways and Spaces Inter-building Backbone pathways encompass : –Underground –Tunnels –Aerial

Pathways and Spaces  16 All pathways where the Backbone subsystem cables are installed shall be intended for this purpose and shall not share their space with other services of the building  17 The Backbone distribution system pathways shall be designed and installed in compliance with local and federal construction regulations and electrical safety codes

Pathways and Spaces  22 All rules given in subsection “Telecommunications pathways and spaces” of section “HORIZONTAL SUBSYSTEM” of this Manual and the ones relating to design and installation of telecommunication distribution systems shall be followed for Backbone cabling subsystem