Dr Emma Rushforth (originally by Prof Ken Young/ Margret Low)

Slides:



Advertisements
Similar presentations
Health & Safety Life Book AM ST p. 1 v.01 - Nov. 03, 2011 Isolation Lockout; protect employees during e.g. maintenance and jam clearing! Machine.
Advertisements

COMPUTER NETWORK TOPOLOGIES
Computer Network Topologies
Virtualisation From the Bottom Up From storage to application.
1 Guards Prevent Access If Infeasible Devices Control Access.
Working for the future - today
Chapter 2 Basic Concepts Line Configuration Topology Transmission Mode Categories of Networks Internetworks WCB/McGraw-Hill  The McGraw-Hill Companies,
1 BROOKHAVEN SCIENCE ASSOCIATES NSLS-II Shielding Workshop S. Buda Personnel Protective Systems March 27, 2007.
Material Handling Modules Configuring Your Own Work Cells.
Title Page/Welcome Splash Screen Machine Safeguarding Kartik Vashi 6 Steps to… Turning Workplaces Into Safe Places®
Regulations and Guidelines for
Mike Marr Safety Consultant Specialist
Vehicle Loading Crane Improvements Mark Hill Site Senior Executive BMA Blackwater Mine.
Proximity Technology Update Hadley Richardson South East Account Manager 24 th of May, 2011.
Linkage Connecting system components. Allows configuring automatic actions Triggering outputs based on specific inputs Used for removing human reliance.
Chapter 19: Network Management Business Data Communications, 4e.
Enhancing Paper Mill Performance through Advanced Diagnostics Services Dr. BS Babji Process Automation Division ABB India Ltd, Bangalore IPPTA Zonal Seminar.
Controlling Hazardous Energy
LynTec … Simplifies AC Power Control Specializes in remotely operated AC power control of installed audio, lighting and video systems Audio: One-Touch.
T. Bajd, M. Mihelj, J. Lenarčič, A. Stanovnik, M. Munih, Robotics, Springer, 2010 SAFETY IN INDUSTRIAL ROBOTICS R. Kamnik, T. Bajd and M. Mihelj.
Products/Motion Motion Controller Intelligent Technology for Moving Performance MELSEC System Q.
Design, Implementation and Maintenance
ROBOT SAFETY OBJECTIVES: BE ACQUAINTED WITH ROBOITIC SAFETY.
International Scientific & Technical Conference
Unit 3a Industrial Control Systems
School Safety Training
QUALITY MANAGEMENT SYSTEM ACCORDING TO ISO
Striving For Safety Excellence HunterDouglas Corporate Environmental, Safety, Risk Management Machine Guarding April 2011.
Operating System A program that controls the execution of application programs An interface between applications and hardware 1.
PLC introduction1 Discrete Event Control Concept Representation DEC controller design DEC controller implementation.
PLC: Programmable Logical Controller
SAFE 645 Principles of Occupational Safety Overview of Automated Processes and Equipment.
JANUS TYPE 4 SAFETY LIGHT CURTAINS applications.
Levels of safety Priorities for eliminating hazards in the workplace Eliminate the hazard through the machine design stage Apply safeguarding technology.
XS26-2 Expandable Safety Controller.
RISK ASSESSMENT AND MANAGEMENT
Protecting the Public, Astronauts and Pilots, the NASA Workforce, and High-Value Equipment and Property Mission Success Starts With Safety Believe it or.
©2008 Pearson Education, Inc., Upper Saddle River, NJ. All rights reserved. This material is protected under all copyright laws as they currently exist.
 Injury  Hazards  Conditional Circumstances  Legal Responsibilities  Guidelines for Safe Products/systems  Safety Hierarchy  Safe Design Principles.
Safety Interlock Refresher Collider-Accelerator Department Take 5 for Safety.
Safety in Work Cells n Issues, mechanisms and equipment, preventative measures.
This Project is funded by the European Union Project implemented by Human Dynamics Consortium This project is funded by the European Union Projekat finansira.
Utility Engineers, PC.  Generation  Transmission  Distribution.
Unit 17: SDLC. Systems Development Life Cycle Five Major Phases Plus Documentation throughout Plus Evaluation…
© 2012 Delmar, Cengage Learning Chapter 11 Engineering Controls.
A new fail-safe principle for railway signaling
Robots at Work. A Presentation by: Caspar Broelemann, Robin Weberskirch, Sebastian Pick.
GATE SAFETY WEEK TH OCTOBER GUIDANCE FOR HOMEOWNERS AND THE PUBLIC KEEPING THE NATION SAFE A guide to keeping you safe around powered gates.
Fundamentals of Machine Guarding
PERSONAL SAFETY INTERLOCKS External EHS Expert Panel Workshop
OH&S Plant Obligations make
SLS 518 Single Beam Safety Light Barrier Type 4
PSS Plans for Improved Reliability and Availability
Behavioural Safety Use Of Work Equipment.
Self Healing and Dynamic Construction Framework:
Computer Network Topologies
LV Safe Powering from UPS to Clients
Overview Introduction General Register Organization Stack Organization
Machine Guarding Element Summary Training
Bluetooth Based Smart Sensor Network
Manufacturing lesson 6.
Designed-in Logic to Ensure Safety of Integration and Field Engineering of Large Scale CBTC Systems Author: Fenggang Shi.
Workshop on Accelerator Operations
Software testing and configuration : Embedded software testing
Hazard Identification & HAZOP (HAZard and OPerability studies)
Personnel Safety Systems
Phased Array Radars Naval Weapons Systems.
Work Equipment Module 12.
Chapter 2 Operating System Overview
Phenotyping Facility X-ray Awareness Training
Presentation transcript:

Dr Emma Rushforth (originally by Prof Ken Young/ Margret Low) Robot Safety Dr Emma Rushforth (originally by Prof Ken Young/ Margret Low) University of Warwick

Hazard identification & Risk Assessment Operational Characteristics of robots can be significantly different from other machines and equipment. capable of high energy movements through a large operational space. Initiation of movement & path of robot arm different to predict and can vary Operating space can overlap other robots operating space or other machines work zones Operators can be required to work in close proximity to the robot system.

Key Elements Fail safe Reliable Cheap minimal down time Cheap Fast implementation / modification

How it is done traditionally Relays Redundancy Physical barriers Interlocks

Physical barriers Walls & interlocked gates Barriers to material movement and maintenance Impair view of process Tend to cause large cells Keep machine in as well as people out machining spindles lasers

inside

outside

Robot controller Internal E-stop Dead mans handle Mode Teach Automatic Slow Fast Automatic External

Large Cell / Multiple Access Points Maintenance key All personnel outside before system runs

Hardwired relay systems Inflexible Expensive to install Limited reusability

Modern Method Modular hardware Modular software Programmable / configurable systems Networks minimal wiring

Pilz SafetyBUS p and SafetyNET p

Light curtains Machine access guarding Transmitter, receiver and two corner mirrors used for machine guarding

Radar detectors/Light curtains Can be active or inactive Programmable for coverage Allow increased safety during certain parts of cycle Require fast response to incursion

Radar/Light curtains Variable protection zones Light curtain blanking/muting Tool pallet/AGV variable protection zone

Programmable systems Function block based Dual/Triple redundant Programming requires direct contact with a specialist tool & original program code for program development/alteration Monitoring/maintenance software tool does not permit programming

What are the Dangers Functionality hidden in software Easy to program could mean easy to bypass software management (passwords, access, historical records) What is the effect of a device or network failure not all networks are safe & some will mix safe & unsafe devices together on a single network

Control Networks

Figure 1 Lathe E-stop Key Mill Robot door Key Pallet Pallet Light curtain

Modular Safety System PNOZmulti PNOZmulti Configurator Getting Started The XOR gate (Exclusive OR gate) is a digital logic gate that is, a true output (1/HIGH) results if one, and only one, of the inputs to the gate is true. If both inputs are false (0/LOW) or both are true, a false output results. RS flip flop – A RS-flipflop is the simplest possible memory element. To understand the operation of the RS-flipflop (or RS-latch) consider the following scenarios: S=1 and R=0: So SET, Q'=0 and Q=1, Hence, the input combination S=1 and R=0 leads to the flipflop being set to Q=1. S=0 and R=1: Similar to the arguments above, the outputs become Q=0 and Q'=1. We say that the flipflop is reset. S=0 and R=0: Assume the flipflop is set (Q=0 and Q'=1), then the output of the top NOR gate remains at Q=1 and the bottom NOR gate stays at Q'=0. Similarly, when the flipflop is in a reset state (Q=1 and Q'=0), it will remain there with this input combination. Therefore, with inputs S=0 and R=0, the flipflop remains in its state. S=1 and R=1: This input combination must be avoided.

Key interchange Internal Laser Estop Robot K Door switch Door Robot Estop Key interchange external